{"source_record": {"boiler_conditions": {"operating_pressure": 850, "maximum_allowable_working_pressure": 1000, "pressure_unit": "kPa(g)", "boiler_type": "Packaged water-tube steam boiler"}, "device_conditions": {"device_type": "Spring-loaded safety valve", "set_pressure": 950, "capacity_unit": "kg/h", "fluid": "Saturated steam"}, "design_assumptions": [{"name": "Maximum continuous steam generation rate", "value": 2400, "unit": "kg/h", "notes": "Use the stated rate as the capacity basis."}], "calculation_rule": {"rule_name": "Problem-defined minimum relief capacity rule", "standard_reference": "Problem specification; no external code requirement cited", "formula": "Required relief capacity = coefficient × maximum continuous steam generation rate", "coefficient": 1.1}, "question": "Using the supplied rule, what minimum relief capacity is required?", "submitted_answer": {"quantity_name": "Minimum required relief capacity", "value": 2640, "unit": "kg/h", "explanation": "1.10 × 2,400 kg/h = 2,640 kg/h."}, "reference_answer": {"quantity_name": "Minimum required relief capacity", "expected_value": 2640, "expected_unit": "kg/h", "absolute_tolerance": 1, "relative_tolerance": 0.001}}, "normalized_inputs": {"normalized_operating_pressure": 0.85, "normalized_pressure_unit": "MPa(g)", "normalized_set_pressure": 0.95, "normalized_capacity_unit": "kg/h"}, "computed_result": {"quantity_name": "Minimum required relief capacity", "value": 2640, "unit": "kg/h", "calculation_steps": ["Convert operating pressure: 850 kPa(g) ÷ 1,000 = 0.85 MPa(g).", "Convert valve set pressure: 950 kPa(g) ÷ 1,000 = 0.95 MPa(g).", "Apply the supplied capacity rule: 1.10 × 2,400 kg/h = 2,640 kg/h."]}, "verification_result": {"is_correct": true, "value_difference": 0, "unit_matches": true, "verification_notes": "The submitted value equals the reference value in kg/h. The absolute difference is 0, within the stated tolerances."}}
{"source_record": {"boiler_conditions": {"operating_pressure": 12, "maximum_allowable_working_pressure": 16, "pressure_unit": "bar(g)", "boiler_type": "Industrial fire-tube steam boiler"}, "device_conditions": {"device_type": "Direct spring safety valve", "set_pressure": 15.5, "capacity_unit": "lb/h", "fluid": "Steam"}, "design_assumptions": [{"name": "Maximum continuous steam production rate", "value": 1800, "unit": "lb/h", "notes": "The rule uses this supplied rate directly."}], "calculation_rule": {"rule_name": "Problem-defined minimum relief capacity rule", "standard_reference": "Problem specification; no external code requirement cited", "formula": "Required relief capacity = coefficient × maximum continuous steam production rate", "coefficient": 1.25}, "question": "Calculate the minimum required relief capacity from the supplied steam production rate and coefficient.", "submitted_answer": {"quantity_name": "Minimum required relief capacity", "value": 2200, "unit": "lb/h", "explanation": "The reported capacity is 2,200 lb/h."}, "reference_answer": {"quantity_name": "Minimum required relief capacity", "expected_value": 2250, "expected_unit": "lb/h", "absolute_tolerance": 5, "relative_tolerance": 0.002}}, "normalized_inputs": {"normalized_operating_pressure": 1.2, "normalized_pressure_unit": "MPa(g)", "normalized_set_pressure": 1.55, "normalized_capacity_unit": "lb/h"}, "computed_result": {"quantity_name": "Minimum required relief capacity", "value": 2250, "unit": "lb/h", "calculation_steps": ["Convert operating pressure: 12 bar(g) × 0.1 = 1.2 MPa(g).", "Convert valve set pressure: 15.5 bar(g) × 0.1 = 1.55 MPa(g).", "Apply the supplied capacity rule: 1.25 × 1,800 lb/h = 2,250 lb/h."]}, "verification_result": {"is_correct": false, "value_difference": 50, "unit_matches": true, "verification_notes": "The unit matches, but the submitted value is 50 lb/h below the reference. This exceeds the 5 lb/h absolute tolerance and the 0.2% relative tolerance."}}
{"source_record": {"boiler_conditions": {"operating_pressure": 1.6, "maximum_allowable_working_pressure": 2, "pressure_unit": "MPa(g)", "boiler_type": "Once-through steam generator"}, "device_conditions": {"device_type": "Pilot-operated relief valve", "set_pressure": 1.9, "capacity_unit": "kg/h", "fluid": "Steam"}, "design_assumptions": [{"name": "Maximum continuous steam generation rate", "value": 3100, "unit": "kg/h", "notes": "Use the supplied generation rate without additional correction factors."}], "calculation_rule": {"rule_name": "Problem-defined minimum relief capacity rule", "standard_reference": "Problem specification; no external code requirement cited", "formula": "Required relief capacity = coefficient × maximum continuous steam generation rate", "coefficient": 1.08}, "question": "Determine the minimum required relief capacity and verify the submitted value, reported in kg/s.", "submitted_answer": {"quantity_name": "Minimum required relief capacity", "value": 0.93, "unit": "kg/s", "explanation": "Convert 0.93 kg/s to an hourly rate: 0.93 × 3,600 = 3,348 kg/h."}, "reference_answer": {"quantity_name": "Minimum required relief capacity", "expected_value": 3348, "expected_unit": "kg/h", "absolute_tolerance": 2, "relative_tolerance": 0.001}}, "normalized_inputs": {"normalized_operating_pressure": 1.6, "normalized_pressure_unit": "MPa(g)", "normalized_set_pressure": 1.9, "normalized_capacity_unit": "kg/h"}, "computed_result": {"quantity_name": "Minimum required relief capacity", "value": 3348, "unit": "kg/h", "calculation_steps": ["Operating pressure is already in the calculation unit: 1.6 MPa(g).", "Valve set pressure is already in the calculation unit: 1.9 MPa(g).", "Apply the supplied capacity rule: 1.08 × 3,100 kg/h = 3,348 kg/h.", "Convert the submitted rate for comparison: 0.93 kg/s × 3,600 s/h = 3,348 kg/h."]}, "verification_result": {"is_correct": true, "value_difference": 0, "unit_matches": true, "verification_notes": "After converting the submitted rate to kg/h, it equals the reference value. The converted unit is equivalent and the difference is within both stated tolerances."}}