合成工况:R410A风冷式冷水机组稳定运行,负荷约为75%,环境温度约30 °C,水侧进水温度目标为12 °C、出水温度目标为7 °C,水流量稳定,无报警。
该工况下参数组合基本正常:吸气压力为0.82 MPa(g),排气压力为2.35 MPa(g),过热度为6 °C,过冷度为5 °C,进水温度为12 °C,出水温度为7 °C,蒸发温度为2 °C。
{"pressure_unit":"MPa(g)","temperature_unit":"°C","allowed_ranges":{"suction_pressure":[0.6,1.1],"discharge_pressure":[1.6,2.8],"superheat":[4,10],"subcooling":[3,8],"inlet_water_temperature":[8,20],"outlet_water_temperature":[4,15],"evaporation_temperature":[-2,8]},"relations":["排气压力应高于吸气压力至少0.5 MPa","进水温度应高于出水温度","进出...
{ "suction_pressure": { "value": 0.82, "unit": "MPa(g)" }, "discharge_pressure": { "value": 2.35, "unit": "MPa(g)" }, "superheat": { "value": 6, "unit": "°C" }, "subcooling": { "value": 5, "unit": "°C" }, "inlet_water_temperature": { "value": 12, "unit": "°C" ...
{ "passed": true, "issues": [] }
{ "passed": true, "issues": [] }
{ "passed": true, "violated_relations": [] }
{ "passed": true, "issues": [] }
[]
通过
模型答案中的压力、温度和温差单位均符合规则。所有参数处于合成参考范围内;排气压力高于吸气压力,进水温度高于出水温度且进出水温差为5 °C,蒸发温度低于出水温度,参数组合与75%负荷、约30 °C环境及12/7 °C水温工况一致,因此验证通过。
合成工况:R410A冷水机组处于低负荷运行状态,负荷约25%,环境温度约22 °C,控制目标为进水12 °C、出水9 °C,系统要求低负荷时水侧温差保持在3-5 °C。
模型回答给出的参数为:吸气压力0.38 MPa(abs),排气压力1.20 MPa(g),过热度12 °C,过冷度2 °C,进水温度16 °C,出水温度9 °C,蒸发温度0 °C。
{"pressure_unit":"MPa(g)","temperature_unit":"°C","allowed_ranges":{"suction_pressure":[0.6,1.1],"discharge_pressure":[1.6,2.8],"superheat":[4,10],"subcooling":[3,8],"inlet_water_temperature":[8,20],"outlet_water_temperature":[4,15],"evaporation_temperature":[-2,8]},"relations":["压力比较必须建立在相同的表压单位上","排气压力应高于吸气压力至少0.5 MP...
{ "suction_pressure": { "value": 0.38, "unit": "MPa(abs)" }, "discharge_pressure": { "value": 1.2, "unit": "MPa(g)" }, "superheat": { "value": 12, "unit": "°C" }, "subcooling": { "value": 2, "unit": "°C" }, "inlet_water_temperature": { "value": 16, "unit": "°C" ...
{ "passed": false, "issues": [ "吸气压力使用MPa(abs),参考规则要求使用MPa(g)。" ] }
{ "passed": false, "issues": [ "吸气压力为绝压,无法直接按MPa(g)范围0.6-1.1进行判断。", "排气压力1.20 MPa(g)低于允许范围1.6-2.8 MPa(g)。", "过热度12 °C高于允许上限10 °C。", "过冷度2 °C低于允许下限3 °C。" ] }
{ "passed": false, "violated_relations": [ "吸气压力为绝压而排气压力为表压,二者不能直接比较压力差。", "低负荷规则要求进出水温差为3-5 °C,答案中的温差为7 °C。" ] }
{ "passed": false, "issues": [ "工况目标为12 °C进水、9 °C出水,但模型答案给出16 °C进水、9 °C出水。", "低负荷工况要求3-5 °C温差,答案中的进出水温差为7 °C。" ] }
[ "单位错误", "范围异常", "关系矛盾", "工况不一致" ]
不通过
吸气压力使用了不符合规则的绝压单位,且无法与表压排气压力直接比较。排气压力偏低,过热度过高,过冷度过低;同时进水温度偏离工况目标,低负荷下7 °C的进出水温差也超出规定范围。综合判断为不通过。
合成工况:R410A风冷式冷水机组在环境温度约38 °C、接近100%负荷下运行,水侧目标为进水14 °C、出水8 °C,风道和水流量均设定为正常状态。
模型回答给出的运行参数为:吸气压力1.05 MPa(g),排气压力1.65 MPa(g),过热度5 °C,过冷度4 °C,进水温度14 °C,出水温度8 °C,蒸发温度10 °C。
{"pressure_unit":"MPa(g)","temperature_unit":"°C","allowed_ranges":{"suction_pressure":[0.6,1.1],"discharge_pressure":[1.6,2.8],"superheat":[4,10],"subcooling":[3,8],"inlet_water_temperature":[8,20],"outlet_water_temperature":[4,15],"evaporation_temperature":[-2,12]},"relations":["排气压力应高于吸气压力至少0.5 MPa","进水温度应高于出水温度","进...
{ "suction_pressure": { "value": 1.05, "unit": "MPa(g)" }, "discharge_pressure": { "value": 1.65, "unit": "MPa(g)" }, "superheat": { "value": 5, "unit": "°C" }, "subcooling": { "value": 4, "unit": "°C" }, "inlet_water_temperature": { "value": 14, "unit": "°C" ...
{ "passed": true, "issues": [] }
{ "passed": true, "issues": [] }
{ "passed": false, "violated_relations": [ "蒸发温度为10 °C,高于出水温度8 °C,未满足蒸发温度应低于出水温度至少1 °C的关系。" ] }
{ "passed": false, "issues": [ "环境温度约38 °C且接近满负荷时,排气压力应达到2.0-2.8 MPa(g),答案中的1.65 MPa(g)偏低。", "满负荷高环境温度工况要求蒸发温度不高于7 °C,答案中的10 °C偏高。" ] }
[ "关系矛盾", "工况不一致" ]
部分通过
所有参数的单位正确,数值也落在通用参考范围内,且压力差、进出水方向和温差基本满足要求。但蒸发温度高于出水温度,违反了蒸发侧换热关系;在38 °C环境和接近满负荷条件下,排气压力偏低、蒸发温度偏高,与特定工况规则不一致,因此总体为部分通过。

Refrigeration Operating Parameter Consistency Answer Validation Dataset

Designed for answer validation in industrial refrigeration, this dataset links operating conditions, model responses, reference rules, and validation results in structured records. It covers parameters such as suction pressure, discharge pressure, superheat, subcooling, inlet and outlet water temperatures, and evaporation temperature, supporting checks of parameter extraction, units, plausible ranges, physical relationships, and consistency with operating conditions. The records can support automated evaluation of refrigeration models, answer quality analysis, and validation workflow development.

Introduction

Validate refrigeration model answers for unit accuracy, plausible ranges, physical relationships, and operating-condition consistency.

Dataset details

  • Sample rows in this repo: 3
  • Full dataset size: 3303 piece
  • Full dataset file size: 0.11 GB
  • Modality: text
  • Language: zh
  • Industry: Industrial Refrigeration Equipment

Upload this folder to a Hugging Face dataset repository. samples.jsonl is the sample split. The full dataset size above is the listing size, not the number of rows in the file.

Fields

Field Description
operating_condition_description {'title': 'Operating Condition Description', 'description': 'Original operating context, including refrigeration equipment status, load, ambient conditions, and relevant operational background.'}
model_answer {'title': 'Model Answer', 'description': 'The model response to be validated, typically containing parameters such as suction pressure, discharge pressure, superheat, subcooling, inlet and outlet water temperatures, and evaporation temperature.'}
reference_rules {'title': 'Reference Rules', 'description': 'Reference relationships, unit requirements, plausible ranges, and operating-condition consistency rules used to validate the model answer, stored as JSON text.'}
extracted_parameters {'title': 'Extracted Answer Parameters', 'description': 'Refrigeration operating parameters parsed and standardized from the model answer.'}
unit_validation {'title': 'Unit Validation Results', 'description': 'Checks whether units for the operating parameters are present, standardized, and compliant with the reference rules.'}
range_validation {'title': 'Range Validation Results', 'description': 'Checks whether extracted operating parameters fall within the plausible ranges specified by the reference rules.'}
relationship_validation {'title': 'Parameter Relationship Validation Results', 'description': 'Checks whether suction pressure, discharge pressure, superheat, subcooling, and temperature parameters satisfy the referenced physical relationships.'}
condition_consistency_validation {'title': 'Operating Condition Consistency Validation Results', 'description': 'Checks whether the parameter combination in the model answer is consistent with the described operating conditions.'}
anomaly_labels {'title': 'Anomaly Labels', 'description': 'Anomaly categories generated from validation results, such as unit errors, out-of-range values, contradictory relationships, or operating-condition inconsistencies.'}
overall_validation_result {'title': 'Overall Validation Result', 'description': 'Overall conclusion based on unit, range, parameter relationship, and operating-condition consistency checks.'}
validation_summary {'title': 'Validation Summary', 'description': 'A Chinese-language summary of the validation process, major anomalies, and overall conclusion.'}

FAQ

Which refrigeration parameters are covered?

Records cover parameters including suction pressure, discharge pressure, superheat, subcooling, inlet and outlet water temperatures, and evaporation temperature. They also include operating context such as equipment status, load, ambient conditions, and relevant operational background.

How are model answers validated?

Model responses are linked to reference rules for checking extracted parameters, unit conventions, plausible value ranges, physical relationships between parameters, and consistency with the described operating conditions.

Which tasks is the dataset suitable for?

It can support answer validation and automated evaluation for industrial refrigeration, as well as parameter extraction, unit validation, range checking, relationship consistency checking, and anomaly classification.

How can the data be accessed and used?

The data is organized as structured JSON fields. Refer to the product page or applicable license for access options, permitted uses, and commercial terms. Reference rules should be reviewed against the relevant equipment and operating conditions before use.

For more dataset information, please visit https://www.mobiusi.com or email contact@mobiusi.com