example_id
stringlengths
33
38
window_id
stringlengths
27
32
version
float64
20.1
23.1
file
stringclasses
9 values
split
stringclasses
3 values
window_kind
stringclasses
2 values
anchor
stringclasses
97 values
scored
bool
2 classes
start
stringdate
2019-09-11 20:05:41
2022-08-21 02:50:17
loop
stringclasses
6 values
label
stringclasses
2 values
attack_ids
stringclasses
97 values
loop_uncertain
bool
2 classes
attack_start_s
int64
-1
297
attack_end_s
int64
-1
3.15k
attack_runs
stringlengths
5
79
⌀
no_visible_change
bool
2 classes
reacting
bool
2 classes
train_use
bool
2 classes
tags
stringclasses
8 values
roles
stringclasses
5 values
source_tags
stringclasses
14 values
matched_from
stringclasses
10 values
answer
stringlengths
37
233
⌀
21.03/test2/20200710T124741/P1-PC
21.03/test2/20200710T124741
21.03
test2
train
attack
A214
false
2020-07-10 12:47:41
P1-PC
attack
A214
false
210
361
210-361
false
false
true
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The first valve command falls from second 212 while the target and second valve command stay flat. The measurement falls after it. Change starts near second 210. Answer: attack
21.03/test2/20200710T124741/P1-LC
21.03/test2/20200710T124741
21.03
test2
train
attack
A214
false
2020-07-10 12:47:41
P1-LC
normal
null
false
-1
-1
null
false
false
false
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target and the measurement stay flat. The command rises. Answer: normal
21.03/test2/20200710T124741/P1-FC
21.03/test2/20200710T124741
21.03
test2
train
attack
A214
false
2020-07-10 12:47:41
P1-FC
normal
null
false
-1
-1
null
false
false
true
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The target and the measurement stay flat. The command rises. Answer: normal
21.03/test2/20200710T124741/P1-TC
21.03/test2/20200710T124741
21.03
test2
train
attack
A214
false
2020-07-10 12:47:41
P1-TC
normal
null
false
-1
-1
null
false
false
true
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T124741/P2-SC
21.03/test2/20200710T124741
21.03
test2
train
attack
A214
false
2020-07-10 12:47:41
P2-SC
normal
null
false
-1
-1
null
false
false
false
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement stays flat. The command stays flat. Answer: normal
21.03/test2/20200710T124741/P3-LC
21.03/test2/20200710T124741
21.03
test2
train
attack
A214
false
2020-07-10 12:47:41
P3-LC
normal
null
false
-1
-1
null
false
false
true
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T124719/P1-PC
21.03/test2/20200710T124719
21.03
test2
train
attack
A214
false
2020-07-10 12:47:19
P1-PC
attack
A214
false
232
383
232-383
false
false
true
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The first valve command falls from second 234 while the target and second valve command stay flat. The measurement falls after it. Change starts near second 232. Answer: attack
21.03/test2/20200710T124719/P1-LC
21.03/test2/20200710T124719
21.03
test2
train
attack
A214
false
2020-07-10 12:47:19
P1-LC
normal
null
false
-1
-1
null
false
false
true
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target and the measurement stay flat. The command rises. Answer: normal
21.03/test2/20200710T124719/P1-FC
21.03/test2/20200710T124719
21.03
test2
train
attack
A214
false
2020-07-10 12:47:19
P1-FC
normal
null
false
-1
-1
null
false
false
false
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T124719/P1-TC
21.03/test2/20200710T124719
21.03
test2
train
attack
A214
false
2020-07-10 12:47:19
P1-TC
normal
null
false
-1
-1
null
false
false
true
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target stays flat while the measurement falls. The command stays flat. Answer: normal
21.03/test2/20200710T124719/P2-SC
21.03/test2/20200710T124719
21.03
test2
train
attack
A214
false
2020-07-10 12:47:19
P2-SC
normal
null
false
-1
-1
null
false
false
true
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement stays flat. The command stays flat. Answer: normal
21.03/test2/20200710T124719/P3-LC
21.03/test2/20200710T124719
21.03
test2
train
attack
A214
false
2020-07-10 12:47:19
P3-LC
normal
null
false
-1
-1
null
false
false
false
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T151015/P1-PC
21.03/test2/20200710T151015
21.03
test2
train
attack
A215
true
2020-07-10 15:10:15
P1-PC
normal
null
false
-1
-1
null
false
false
true
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T151015/P1-LC
21.03/test2/20200710T151015
21.03
test2
train
attack
A215
true
2020-07-10 15:10:15
P1-LC
normal
null
false
-1
-1
null
false
false
true
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T151015/P1-FC
21.03/test2/20200710T151015
21.03
test2
train
attack
A215
true
2020-07-10 15:10:15
P1-FC
normal
null
false
-1
-1
null
false
false
true
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T151015/P1-TC
21.03/test2/20200710T151015
21.03
test2
train
attack
A215
true
2020-07-10 15:10:15
P1-TC
normal
null
false
-1
-1
null
false
false
true
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target stays flat while the measurement rises. The command stays flat. Answer: normal
21.03/test2/20200710T151015/P2-SC
21.03/test2/20200710T151015
21.03
test2
train
attack
A215
true
2020-07-10 15:10:15
P2-SC
attack
A215
false
49
199
49-199
false
false
true
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement starts swinging from second 49. The command rises after it. Change starts near second 49. Answer: attack
21.03/test2/20200710T151015/P3-LC
21.03/test2/20200710T151015
21.03
test2
train
attack
A215
true
2020-07-10 15:10:15
P3-LC
normal
null
false
-1
-1
null
false
false
true
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150919/P1-PC
21.03/test2/20200710T150919
21.03
test2
train
attack
A215
false
2020-07-10 15:09:19
P1-PC
normal
null
false
-1
-1
null
false
false
true
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150919/P1-LC
21.03/test2/20200710T150919
21.03
test2
train
attack
A215
false
2020-07-10 15:09:19
P1-LC
normal
null
false
-1
-1
null
false
false
false
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150919/P1-FC
21.03/test2/20200710T150919
21.03
test2
train
attack
A215
false
2020-07-10 15:09:19
P1-FC
normal
null
false
-1
-1
null
false
false
false
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150919/P1-TC
21.03/test2/20200710T150919
21.03
test2
train
attack
A215
false
2020-07-10 15:09:19
P1-TC
normal
null
false
-1
-1
null
false
false
false
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target stays flat while the measurement rises. The command stays flat. Answer: normal
21.03/test2/20200710T150919/P2-SC
21.03/test2/20200710T150919
21.03
test2
train
attack
A215
false
2020-07-10 15:09:19
P2-SC
attack
A215
false
105
255
105-255
false
false
true
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement starts swinging from second 105. The command rises after it. Change starts near second 105. Answer: attack
21.03/test2/20200710T150919/P3-LC
21.03/test2/20200710T150919
21.03
test2
train
attack
A215
false
2020-07-10 15:09:19
P3-LC
normal
null
false
-1
-1
null
false
false
false
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150846/P1-PC
21.03/test2/20200710T150846
21.03
test2
train
attack
A215
false
2020-07-10 15:08:46
P1-PC
normal
null
false
-1
-1
null
false
false
true
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150846/P1-LC
21.03/test2/20200710T150846
21.03
test2
train
attack
A215
false
2020-07-10 15:08:46
P1-LC
normal
null
false
-1
-1
null
false
false
false
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150846/P1-FC
21.03/test2/20200710T150846
21.03
test2
train
attack
A215
false
2020-07-10 15:08:46
P1-FC
normal
null
false
-1
-1
null
false
false
true
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150846/P1-TC
21.03/test2/20200710T150846
21.03
test2
train
attack
A215
false
2020-07-10 15:08:46
P1-TC
normal
null
false
-1
-1
null
false
false
false
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150846/P2-SC
21.03/test2/20200710T150846
21.03
test2
train
attack
A215
false
2020-07-10 15:08:46
P2-SC
attack
A215
false
138
288
138-288
false
false
true
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement starts swinging from second 138. The command rises after it. Change starts near second 138. Answer: attack
21.03/test2/20200710T150846/P3-LC
21.03/test2/20200710T150846
21.03
test2
train
attack
A215
false
2020-07-10 15:08:46
P3-LC
normal
null
false
-1
-1
null
false
false
true
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150818/P1-PC
21.03/test2/20200710T150818
21.03
test2
train
attack
A215
false
2020-07-10 15:08:18
P1-PC
normal
null
false
-1
-1
null
false
false
false
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The target and the measurement stay flat. The command falls. Answer: normal
21.03/test2/20200710T150818/P1-LC
21.03/test2/20200710T150818
21.03
test2
train
attack
A215
false
2020-07-10 15:08:18
P1-LC
normal
null
false
-1
-1
null
false
false
false
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150818/P1-FC
21.03/test2/20200710T150818
21.03
test2
train
attack
A215
false
2020-07-10 15:08:18
P1-FC
normal
null
false
-1
-1
null
false
false
true
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150818/P1-TC
21.03/test2/20200710T150818
21.03
test2
train
attack
A215
false
2020-07-10 15:08:18
P1-TC
normal
null
false
-1
-1
null
false
false
false
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150818/P2-SC
21.03/test2/20200710T150818
21.03
test2
train
attack
A215
false
2020-07-10 15:08:18
P2-SC
attack
A215
false
166
316
166-316
false
false
true
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement starts swinging from second 166. The command rises after it. Change starts near second 166. Answer: attack
21.03/test2/20200710T150818/P3-LC
21.03/test2/20200710T150818
21.03
test2
train
attack
A215
false
2020-07-10 15:08:18
P3-LC
normal
null
false
-1
-1
null
false
false
true
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150749/P1-PC
21.03/test2/20200710T150749
21.03
test2
train
attack
A215
false
2020-07-10 15:07:49
P1-PC
normal
null
false
-1
-1
null
false
false
true
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The target and the measurement stay flat. The command falls. Answer: normal
21.03/test2/20200710T150749/P1-LC
21.03/test2/20200710T150749
21.03
test2
train
attack
A215
false
2020-07-10 15:07:49
P1-LC
normal
null
false
-1
-1
null
false
false
true
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150749/P1-FC
21.03/test2/20200710T150749
21.03
test2
train
attack
A215
false
2020-07-10 15:07:49
P1-FC
normal
null
false
-1
-1
null
false
false
false
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150749/P1-TC
21.03/test2/20200710T150749
21.03
test2
train
attack
A215
false
2020-07-10 15:07:49
P1-TC
normal
null
false
-1
-1
null
false
false
true
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150749/P2-SC
21.03/test2/20200710T150749
21.03
test2
train
attack
A215
false
2020-07-10 15:07:49
P2-SC
attack
A215
false
195
345
195-345
false
false
true
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement starts swinging from second 195. The command rises after it. Change starts near second 195. Answer: attack
21.03/test2/20200710T150749/P3-LC
21.03/test2/20200710T150749
21.03
test2
train
attack
A215
false
2020-07-10 15:07:49
P3-LC
normal
null
false
-1
-1
null
false
false
false
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150635/P1-PC
21.03/test2/20200710T150635
21.03
test2
train
attack
A215
false
2020-07-10 15:06:35
P1-PC
normal
null
false
-1
-1
null
false
false
false
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The target and the measurement stay flat. The command falls. Answer: normal
21.03/test2/20200710T150635/P1-LC
21.03/test2/20200710T150635
21.03
test2
train
attack
A215
false
2020-07-10 15:06:35
P1-LC
normal
null
false
-1
-1
null
false
false
false
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150635/P1-FC
21.03/test2/20200710T150635
21.03
test2
train
attack
A215
false
2020-07-10 15:06:35
P1-FC
normal
null
false
-1
-1
null
false
false
false
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150635/P1-TC
21.03/test2/20200710T150635
21.03
test2
train
attack
A215
false
2020-07-10 15:06:35
P1-TC
normal
null
false
-1
-1
null
false
false
false
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T150635/P2-SC
21.03/test2/20200710T150635
21.03
test2
train
attack
A215
false
2020-07-10 15:06:35
P2-SC
attack
A215
false
269
419
269-419
false
false
true
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement starts swinging from second 269. The command rises after it. Change starts near second 269. Answer: attack
21.03/test2/20200710T150635/P3-LC
21.03/test2/20200710T150635
21.03
test2
train
attack
A215
false
2020-07-10 15:06:35
P3-LC
normal
null
false
-1
-1
null
false
false
true
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T153921/P1-PC
21.03/test2/20200710T153921
21.03
test2
train
attack
A216
false
2020-07-10 15:39:21
P1-PC
normal
null
false
-1
-1
null
false
false
false
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T153921/P1-LC
21.03/test2/20200710T153921
21.03
test2
train
attack
A216
false
2020-07-10 15:39:21
P1-LC
normal
null
false
-1
-1
null
false
false
false
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T153921/P1-FC
21.03/test2/20200710T153921
21.03
test2
train
attack
A216
false
2020-07-10 15:39:21
P1-FC
attack
A216
false
45
109
45-55 65-70 72-75 85-94 104-109
false
false
true
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The command rises from second 45 while the target stays flat. The measurement rises after it. Change starts near second 45. Answer: attack
21.03/test2/20200710T153921/P1-TC
21.03/test2/20200710T153921
21.03
test2
train
attack
A216
false
2020-07-10 15:39:21
P1-TC
normal
null
false
-1
-1
null
false
false
true
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T153921/P2-SC
21.03/test2/20200710T153921
21.03
test2
train
attack
A216
false
2020-07-10 15:39:21
P2-SC
normal
null
false
-1
-1
null
false
false
false
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement stays flat. The command stays flat. Answer: normal
21.03/test2/20200710T153921/P3-LC
21.03/test2/20200710T153921
21.03
test2
train
attack
A216
false
2020-07-10 15:39:21
P3-LC
normal
null
false
-1
-1
null
false
false
true
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target stays flat while the measurement rises. The command stays flat. Answer: normal
21.03/test2/20200710T153848/P1-PC
21.03/test2/20200710T153848
21.03
test2
train
attack
A216
false
2020-07-10 15:38:48
P1-PC
normal
null
false
-1
-1
null
false
false
true
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The target and the measurement stay flat. The command falls. Answer: normal
21.03/test2/20200710T153848/P1-LC
21.03/test2/20200710T153848
21.03
test2
train
attack
A216
false
2020-07-10 15:38:48
P1-LC
normal
null
false
-1
-1
null
false
false
false
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T153848/P1-FC
21.03/test2/20200710T153848
21.03
test2
train
attack
A216
false
2020-07-10 15:38:48
P1-FC
attack
A216
false
78
142
78-88 98-103 105-108 118-127 137-142
false
false
true
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The command rises from second 78 while the target stays flat. The measurement rises after it. Change starts near second 78. Answer: attack
21.03/test2/20200710T153848/P1-TC
21.03/test2/20200710T153848
21.03
test2
train
attack
A216
false
2020-07-10 15:38:48
P1-TC
normal
null
false
-1
-1
null
false
false
true
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T153848/P2-SC
21.03/test2/20200710T153848
21.03
test2
train
attack
A216
false
2020-07-10 15:38:48
P2-SC
normal
null
false
-1
-1
null
false
false
false
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement stays flat. The command stays flat. Answer: normal
21.03/test2/20200710T153848/P3-LC
21.03/test2/20200710T153848
21.03
test2
train
attack
A216
false
2020-07-10 15:38:48
P3-LC
normal
null
false
-1
-1
null
false
false
true
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target stays flat while the measurement rises. The command stays flat. Answer: normal
21.03/test2/20200710T153758/P1-PC
21.03/test2/20200710T153758
21.03
test2
train
attack
A216
false
2020-07-10 15:37:58
P1-PC
normal
null
false
-1
-1
null
false
false
false
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The target and the measurement stay flat. The command falls. Answer: normal
21.03/test2/20200710T153758/P1-LC
21.03/test2/20200710T153758
21.03
test2
train
attack
A216
false
2020-07-10 15:37:58
P1-LC
normal
null
false
-1
-1
null
false
false
false
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target stays flat while the measurement falls. The command stays flat. Answer: normal
21.03/test2/20200710T153758/P1-FC
21.03/test2/20200710T153758
21.03
test2
train
attack
A216
false
2020-07-10 15:37:58
P1-FC
attack
A216
false
128
192
128-138 148-153 155-158 168-177 187-192
false
false
true
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The command rises from second 128 while the target stays flat. The measurement rises after it. Change starts near second 128. Answer: attack
21.03/test2/20200710T153758/P1-TC
21.03/test2/20200710T153758
21.03
test2
train
attack
A216
false
2020-07-10 15:37:58
P1-TC
normal
null
false
-1
-1
null
false
false
false
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target stays flat while the measurement falls. The command stays flat. Answer: normal
21.03/test2/20200710T153758/P2-SC
21.03/test2/20200710T153758
21.03
test2
train
attack
A216
false
2020-07-10 15:37:58
P2-SC
normal
null
false
-1
-1
null
false
false
true
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement stays flat. The command stays flat. Answer: normal
21.03/test2/20200710T153758/P3-LC
21.03/test2/20200710T153758
21.03
test2
train
attack
A216
false
2020-07-10 15:37:58
P3-LC
normal
null
false
-1
-1
null
false
false
false
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T153659/P1-PC
21.03/test2/20200710T153659
21.03
test2
train
attack
A216
false
2020-07-10 15:36:59
P1-PC
normal
null
false
-1
-1
null
false
false
false
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T153659/P1-LC
21.03/test2/20200710T153659
21.03
test2
train
attack
A216
false
2020-07-10 15:36:59
P1-LC
normal
null
false
-1
-1
null
false
false
true
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target stays flat while the measurement falls. The command falls. Answer: normal
21.03/test2/20200710T153659/P1-FC
21.03/test2/20200710T153659
21.03
test2
train
attack
A216
false
2020-07-10 15:36:59
P1-FC
attack
A216
false
187
251
187-197 207-212 214-217 227-236 246-251
false
false
true
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The command rises from second 187 while the target stays flat. The measurement rises after it. Change starts near second 187. Answer: attack
21.03/test2/20200710T153659/P1-TC
21.03/test2/20200710T153659
21.03
test2
train
attack
A216
false
2020-07-10 15:36:59
P1-TC
normal
null
false
-1
-1
null
false
false
false
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T153659/P2-SC
21.03/test2/20200710T153659
21.03
test2
train
attack
A216
false
2020-07-10 15:36:59
P2-SC
normal
null
false
-1
-1
null
false
false
false
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement stays flat. The command stays flat. Answer: normal
21.03/test2/20200710T153659/P3-LC
21.03/test2/20200710T153659
21.03
test2
train
attack
A216
false
2020-07-10 15:36:59
P3-LC
normal
null
false
-1
-1
null
false
false
false
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T153655/P1-PC
21.03/test2/20200710T153655
21.03
test2
train
attack
A216
false
2020-07-10 15:36:55
P1-PC
normal
null
false
-1
-1
null
false
false
true
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T153655/P1-LC
21.03/test2/20200710T153655
21.03
test2
train
attack
A216
false
2020-07-10 15:36:55
P1-LC
normal
null
false
-1
-1
null
false
false
true
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target stays flat while the measurement falls. The command falls. Answer: normal
21.03/test2/20200710T153655/P1-FC
21.03/test2/20200710T153655
21.03
test2
train
attack
A216
false
2020-07-10 15:36:55
P1-FC
attack
A216
false
191
255
191-201 211-216 218-221 231-240 250-255
false
false
true
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The command rises from second 191 while the target stays flat. The measurement rises after it. Change starts near second 191. Answer: attack
21.03/test2/20200710T153655/P1-TC
21.03/test2/20200710T153655
21.03
test2
train
attack
A216
false
2020-07-10 15:36:55
P1-TC
normal
null
false
-1
-1
null
false
false
false
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T153655/P2-SC
21.03/test2/20200710T153655
21.03
test2
train
attack
A216
false
2020-07-10 15:36:55
P2-SC
normal
null
false
-1
-1
null
false
false
true
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement stays flat. The command stays flat. Answer: normal
21.03/test2/20200710T153655/P3-LC
21.03/test2/20200710T153655
21.03
test2
train
attack
A216
false
2020-07-10 15:36:55
P3-LC
normal
null
false
-1
-1
null
false
false
false
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T153541/P1-PC
21.03/test2/20200710T153541
21.03
test2
train
attack
A216
true
2020-07-10 15:35:41
P1-PC
normal
null
false
-1
-1
null
false
false
false
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The target and the measurement stay flat. The command rises. Answer: normal
21.03/test2/20200710T153541/P1-LC
21.03/test2/20200710T153541
21.03
test2
train
attack
A216
true
2020-07-10 15:35:41
P1-LC
normal
null
false
-1
-1
null
false
false
true
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T153541/P1-FC
21.03/test2/20200710T153541
21.03
test2
train
attack
A216
true
2020-07-10 15:35:41
P1-FC
attack
A216
false
265
295
265-275 285-290 292-295
false
false
true
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The command rises from second 265 while the target stays flat. The measurement rises after it. Change starts near second 265. Answer: attack
21.03/test2/20200710T153541/P1-TC
21.03/test2/20200710T153541
21.03
test2
train
attack
A216
true
2020-07-10 15:35:41
P1-TC
normal
null
false
-1
-1
null
false
false
true
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T153541/P2-SC
21.03/test2/20200710T153541
21.03
test2
train
attack
A216
true
2020-07-10 15:35:41
P2-SC
normal
null
false
-1
-1
null
false
false
true
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement stays flat. The command stays flat. Answer: normal
21.03/test2/20200710T153541/P3-LC
21.03/test2/20200710T153541
21.03
test2
train
attack
A216
true
2020-07-10 15:35:41
P3-LC
normal
null
false
-1
-1
null
false
false
true
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target stays flat while the measurement falls. The command stays flat. Answer: normal
21.03/test2/20200710T182036/P1-PC
21.03/test2/20200710T182036
21.03
test2
train
attack
A218
false
2020-07-10 18:20:36
P1-PC
normal
null
false
-1
-1
null
false
true
false
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T182036/P1-LC
21.03/test2/20200710T182036
21.03
test2
train
attack
A218
false
2020-07-10 18:20:36
P1-LC
normal
null
false
-1
-1
null
false
false
true
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T182036/P1-FC
21.03/test2/20200710T182036
21.03
test2
train
attack
A218
false
2020-07-10 18:20:36
P1-FC
attack
A218
false
37
135
37-95 97-135
false
false
true
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The command rises from second 37 while the target stays flat. The measurement falls after it. Change starts near second 37. Answer: attack
21.03/test2/20200710T182036/P1-TC
21.03/test2/20200710T182036
21.03
test2
train
attack
A218
false
2020-07-10 18:20:36
P1-TC
normal
null
false
-1
-1
null
false
false
true
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T182036/P2-SC
21.03/test2/20200710T182036
21.03
test2
train
attack
A218
false
2020-07-10 18:20:36
P2-SC
normal
null
false
-1
-1
null
false
false
false
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement stays flat. The command stays flat. Answer: normal
21.03/test2/20200710T182036/P3-LC
21.03/test2/20200710T182036
21.03
test2
train
attack
A218
false
2020-07-10 18:20:36
P3-LC
normal
null
false
-1
-1
null
false
false
false
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target and the measurement stay flat. The command rises. Answer: normal
21.03/test2/20200710T181927/P1-PC
21.03/test2/20200710T181927
21.03
test2
train
attack
A218
false
2020-07-10 18:19:27
P1-PC
normal
null
false
-1
-1
null
false
true
false
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The target and the measurement stay flat. The command rises. Answer: normal
21.03/test2/20200710T181927/P1-LC
21.03/test2/20200710T181927
21.03
test2
train
attack
A218
false
2020-07-10 18:19:27
P1-LC
normal
null
false
-1
-1
null
false
false
true
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target and the measurement stay flat. The command rises. Answer: normal
21.03/test2/20200710T181927/P1-FC
21.03/test2/20200710T181927
21.03
test2
train
attack
A218
false
2020-07-10 18:19:27
P1-FC
attack
A218
false
106
204
106-164 166-204
false
false
true
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The command rises from second 106 while the target and measurement stay flat. Change starts near second 106. Answer: attack
21.03/test2/20200710T181927/P1-TC
21.03/test2/20200710T181927
21.03
test2
train
attack
A218
false
2020-07-10 18:19:27
P1-TC
normal
null
false
-1
-1
null
false
false
false
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal
21.03/test2/20200710T181927/P2-SC
21.03/test2/20200710T181927
21.03
test2
train
attack
A218
false
2020-07-10 18:19:27
P2-SC
normal
null
false
-1
-1
null
false
false
true
P2_SIT01 P2_SCO
measurement command
P2_SIT01 P2_CO_rpm
same_name data
The measurement stays flat. The command stays flat. Answer: normal
21.03/test2/20200710T181927/P3-LC
21.03/test2/20200710T181927
21.03
test2
train
attack
A218
false
2020-07-10 18:19:27
P3-LC
normal
null
false
-1
-1
null
false
false
false
P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D
target target measurement command command
P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D
name name same_name same_name same_name
The target and the measurement stay flat. The command falls. Answer: normal
21.03/test2/20200710T181919/P1-PC
21.03/test2/20200710T181919
21.03
test2
train
attack
A218
false
2020-07-10 18:19:19
P1-PC
normal
null
false
-1
-1
null
false
true
false
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
target measurement command command
P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D
same_name same_name same_name same_name
The target and the measurement stay flat. The command rises. Answer: normal
21.03/test2/20200710T181919/P1-LC
21.03/test2/20200710T181919
21.03
test2
train
attack
A218
false
2020-07-10 18:19:19
P1-LC
normal
null
false
-1
-1
null
false
false
true
P1_B3004 P1_LIT01 P1_LCV01D
target measurement command
P1_B3004 P1_LIT01 P1_LCV01D
same_name same_name same_name
The target and the measurement stay flat. The command rises. Answer: normal
21.03/test2/20200710T181919/P1-FC
21.03/test2/20200710T181919
21.03
test2
train
attack
A218
false
2020-07-10 18:19:19
P1-FC
attack
A218
false
114
212
114-172 174-212
false
false
true
P1_B3005 P1_FT03 P1_FCV03D
target measurement command
P1_B3005 P1_FT03 P1_FCV03D
same_name same_name same_name
The command rises from second 114 while the target and measurement stay flat. Change starts near second 114. Answer: attack
21.03/test2/20200710T181919/P1-TC
21.03/test2/20200710T181919
21.03
test2
train
attack
A218
false
2020-07-10 18:19:19
P1-TC
normal
null
false
-1
-1
null
false
false
true
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
target target measurement command command
P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D
same_name same_name same_name same_name same_name
The target and the measurement stay flat. The command stays flat. Answer: normal