example_id stringlengths 33 38 | window_id stringlengths 27 32 | version float64 20.1 23.1 | file stringclasses 9
values | split stringclasses 3
values | window_kind stringclasses 2
values | anchor stringclasses 97
values | scored bool 2
classes | start stringdate 2019-09-11 20:05:41 2022-08-21 02:50:17 | loop stringclasses 6
values | label stringclasses 2
values | attack_ids stringclasses 97
values | loop_uncertain bool 2
classes | attack_start_s int64 -1 297 | attack_end_s int64 -1 3.15k | attack_runs stringlengths 5 79 ⌀ | no_visible_change bool 2
classes | reacting bool 2
classes | train_use bool 2
classes | tags stringclasses 8
values | roles stringclasses 5
values | source_tags stringclasses 14
values | matched_from stringclasses 10
values | answer stringlengths 37 233 ⌀ |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
21.03/test3/20200713T134918/P1-FC | 21.03/test3/20200713T134918 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:49:18 | P1-FC | attack | A301 | false | 108 | 239 | 108-111 113-239 | false | false | true | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The measurement falls from second 108 while the target and command stay flat. Change starts near second 108. Answer: attack |
21.03/test3/20200713T134918/P1-TC | 21.03/test3/20200713T134918 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:49:18 | P1-TC | normal | null | false | -1 | -1 | null | false | false | true | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The target and the measurement stay flat. The command stays flat. Answer: normal |
21.03/test3/20200713T134918/P2-SC | 21.03/test3/20200713T134918 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:49:18 | P2-SC | normal | null | false | -1 | -1 | null | false | false | false | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T134918/P3-LC | 21.03/test3/20200713T134918 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:49:18 | P3-LC | normal | null | false | -1 | -1 | null | false | false | false | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target and the measurement stay flat. The command rises. Answer: normal |
21.03/test3/20200713T134853/P1-PC | 21.03/test3/20200713T134853 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:48:53 | P1-PC | normal | null | false | -1 | -1 | null | false | true | false | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The target and the measurement stay flat. The command falls. Answer: normal |
21.03/test3/20200713T134853/P1-LC | 21.03/test3/20200713T134853 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:48:53 | P1-LC | attack | A301 | false | 133 | 264 | 133-136 138-264 | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The measurement falls from second 133 while the target and command stay flat. Change starts near second 133. Answer: attack |
21.03/test3/20200713T134853/P1-FC | 21.03/test3/20200713T134853 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:48:53 | P1-FC | attack | A301 | false | 133 | 264 | 133-136 138-264 | false | false | true | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The measurement falls from second 133 while the target and command stay flat. Change starts near second 133. Answer: attack |
21.03/test3/20200713T134853/P1-TC | 21.03/test3/20200713T134853 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:48:53 | P1-TC | normal | null | false | -1 | -1 | null | false | false | false | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The target and the measurement stay flat. The command stays flat. Answer: normal |
21.03/test3/20200713T134853/P2-SC | 21.03/test3/20200713T134853 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:48:53 | P2-SC | normal | null | false | -1 | -1 | null | false | false | true | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T134853/P3-LC | 21.03/test3/20200713T134853 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:48:53 | P3-LC | normal | null | false | -1 | -1 | null | false | false | true | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target and the measurement stay flat. The command stays flat. Answer: normal |
21.03/test3/20200713T134759/P1-PC | 21.03/test3/20200713T134759 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:47:59 | P1-PC | normal | null | false | -1 | -1 | null | false | true | false | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The measurement follows the target as it falls. The command falls. Answer: normal |
21.03/test3/20200713T134759/P1-LC | 21.03/test3/20200713T134759 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:47:59 | P1-LC | attack | A301 | false | 187 | 318 | 187-190 192-318 | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The measurement falls from second 187 while the target and command stay flat. Change starts near second 187. Answer: attack |
21.03/test3/20200713T134759/P1-FC | 21.03/test3/20200713T134759 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:47:59 | P1-FC | attack | A301 | false | 187 | 318 | 187-190 192-318 | false | false | true | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The measurement falls from second 187 while the target and command stay flat. Change starts near second 187. Answer: attack |
21.03/test3/20200713T134759/P1-TC | 21.03/test3/20200713T134759 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:47:59 | P1-TC | normal | null | false | -1 | -1 | null | false | false | false | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The measurement follows the target as it falls. The command stays flat. Answer: normal |
21.03/test3/20200713T134759/P2-SC | 21.03/test3/20200713T134759 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:47:59 | P2-SC | normal | null | false | -1 | -1 | null | false | false | true | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T134759/P3-LC | 21.03/test3/20200713T134759 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:47:59 | P3-LC | normal | null | false | -1 | -1 | null | false | false | true | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target stays flat while the measurement rises. The command stays flat. Answer: normal |
21.03/test3/20200713T134742/P1-PC | 21.03/test3/20200713T134742 | 21.03 | test3 | train | attack | A301 | true | 2020-07-13 13:47:42 | P1-PC | normal | null | false | -1 | -1 | null | false | true | false | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The target falls and the measurement starts swinging. The command falls. Answer: normal |
21.03/test3/20200713T134742/P1-LC | 21.03/test3/20200713T134742 | 21.03 | test3 | train | attack | A301 | true | 2020-07-13 13:47:42 | P1-LC | attack | A301 | false | 204 | 335 | 204-207 209-335 | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The measurement falls from second 204 while the target and command stay flat. Change starts near second 204. Answer: attack |
21.03/test3/20200713T134742/P1-FC | 21.03/test3/20200713T134742 | 21.03 | test3 | train | attack | A301 | true | 2020-07-13 13:47:42 | P1-FC | attack | A301 | false | 204 | 335 | 204-207 209-335 | false | false | true | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The measurement falls from second 204 while the target and command stay flat. Change starts near second 204. Answer: attack |
21.03/test3/20200713T134742/P1-TC | 21.03/test3/20200713T134742 | 21.03 | test3 | train | attack | A301 | true | 2020-07-13 13:47:42 | P1-TC | normal | null | false | -1 | -1 | null | false | false | false | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The measurement follows the target as it falls. The command stays flat. Answer: normal |
21.03/test3/20200713T134742/P2-SC | 21.03/test3/20200713T134742 | 21.03 | test3 | train | attack | A301 | true | 2020-07-13 13:47:42 | P2-SC | normal | null | false | -1 | -1 | null | false | false | true | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T134742/P3-LC | 21.03/test3/20200713T134742 | 21.03 | test3 | train | attack | A301 | true | 2020-07-13 13:47:42 | P3-LC | normal | null | false | -1 | -1 | null | false | false | false | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target stays flat while the measurement rises. The command stays flat. Answer: normal |
21.03/test3/20200713T134659/P1-PC | 21.03/test3/20200713T134659 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:46:59 | P1-PC | normal | null | false | -1 | -1 | null | false | true | false | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The target stays flat while the measurement rises. The command falls. Answer: normal |
21.03/test3/20200713T134659/P1-LC | 21.03/test3/20200713T134659 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:46:59 | P1-LC | attack | A301 | false | 247 | 378 | 247-250 252-378 | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The measurement falls from second 247 while the target and command stay flat. Change starts near second 247. Answer: attack |
21.03/test3/20200713T134659/P1-FC | 21.03/test3/20200713T134659 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:46:59 | P1-FC | attack | A301 | false | 247 | 378 | 247-250 252-378 | false | false | true | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The command falls from second 247 while the target stays flat. The measurement falls with it. Change starts near second 247. Answer: attack |
21.03/test3/20200713T134659/P1-TC | 21.03/test3/20200713T134659 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:46:59 | P1-TC | normal | null | false | -1 | -1 | null | false | false | true | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The target and the measurement stay flat. The command stays flat. Answer: normal |
21.03/test3/20200713T134659/P2-SC | 21.03/test3/20200713T134659 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:46:59 | P2-SC | normal | null | false | -1 | -1 | null | false | false | false | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T134659/P3-LC | 21.03/test3/20200713T134659 | 21.03 | test3 | train | attack | A301 | false | 2020-07-13 13:46:59 | P3-LC | normal | null | false | -1 | -1 | null | false | false | true | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target stays flat while the measurement rises. The command stays flat. Answer: normal |
21.03/test3/20200713T152007/P1-PC | 21.03/test3/20200713T152007 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:20:07 | P1-PC | attack | A302 | false | 53 | 473 | 53-473 | false | false | true | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The first valve command falls from second 55 while the target stays flat. The measurement falls after it. The second valve command rises after it. Change starts near second 53. Answer: attack |
21.03/test3/20200713T152007/P1-LC | 21.03/test3/20200713T152007 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:20:07 | P1-LC | normal | null | false | -1 | -1 | null | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The target stays flat while the measurement falls. The command rises. Answer: normal |
21.03/test3/20200713T152007/P1-FC | 21.03/test3/20200713T152007 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:20:07 | P1-FC | attack | A302 | false | 53 | 473 | 53-473 | false | false | true | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The command rises from second 57 while the target stays flat. The measurement falls after it. Change starts near second 53. Answer: attack |
21.03/test3/20200713T152007/P1-TC | 21.03/test3/20200713T152007 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:20:07 | P1-TC | normal | null | false | -1 | -1 | null | false | false | true | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The target stays flat while the measurement falls. The command stays flat. Answer: normal |
21.03/test3/20200713T152007/P2-SC | 21.03/test3/20200713T152007 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:20:07 | P2-SC | normal | null | false | -1 | -1 | null | false | false | true | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T152007/P3-LC | 21.03/test3/20200713T152007 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:20:07 | P3-LC | normal | null | false | -1 | -1 | null | false | false | true | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target stays flat while the measurement falls. The command stays flat. Answer: normal |
21.03/test3/20200713T151927/P1-PC | 21.03/test3/20200713T151927 | 21.03 | test3 | train | attack | A302 | true | 2020-07-13 15:19:27 | P1-PC | attack | A302 | false | 93 | 513 | 93-513 | false | false | true | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The measurement starts swinging from second 93 while the target stays flat. The first valve command falls with it. The second valve command rises after it. Change starts near second 93. Answer: attack |
21.03/test3/20200713T151927/P1-LC | 21.03/test3/20200713T151927 | 21.03 | test3 | train | attack | A302 | true | 2020-07-13 15:19:27 | P1-LC | normal | null | false | -1 | -1 | null | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The target stays flat while the measurement falls. The command rises. Answer: normal |
21.03/test3/20200713T151927/P1-FC | 21.03/test3/20200713T151927 | 21.03 | test3 | train | attack | A302 | true | 2020-07-13 15:19:27 | P1-FC | attack | A302 | false | 93 | 513 | 93-513 | false | false | true | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The command rises from second 97 while the target stays flat. The measurement falls after it. Change starts near second 93. Answer: attack |
21.03/test3/20200713T151927/P1-TC | 21.03/test3/20200713T151927 | 21.03 | test3 | train | attack | A302 | true | 2020-07-13 15:19:27 | P1-TC | normal | null | false | -1 | -1 | null | false | false | true | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The target stays flat while the measurement falls. The command stays flat. Answer: normal |
21.03/test3/20200713T151927/P2-SC | 21.03/test3/20200713T151927 | 21.03 | test3 | train | attack | A302 | true | 2020-07-13 15:19:27 | P2-SC | normal | null | false | -1 | -1 | null | false | false | false | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T151927/P3-LC | 21.03/test3/20200713T151927 | 21.03 | test3 | train | attack | A302 | true | 2020-07-13 15:19:27 | P3-LC | normal | null | false | -1 | -1 | null | false | false | false | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target stays flat while the measurement falls. The command stays flat. Answer: normal |
21.03/test3/20200713T151843/P1-PC | 21.03/test3/20200713T151843 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:18:43 | P1-PC | attack | A302 | false | 137 | 557 | 137-557 | false | false | true | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The measurement starts swinging from second 137 while the target stays flat. The first valve command falls with it. The second valve command rises after it. Change starts near second 137. Answer: attack |
21.03/test3/20200713T151843/P1-LC | 21.03/test3/20200713T151843 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:18:43 | P1-LC | normal | null | false | -1 | -1 | null | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The target stays flat while the measurement falls. The command rises. Answer: normal |
21.03/test3/20200713T151843/P1-FC | 21.03/test3/20200713T151843 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:18:43 | P1-FC | attack | A302 | false | 137 | 557 | 137-557 | false | false | true | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The command rises from second 141 while the target stays flat. The measurement falls after it. Change starts near second 137. Answer: attack |
21.03/test3/20200713T151843/P1-TC | 21.03/test3/20200713T151843 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:18:43 | P1-TC | normal | null | false | -1 | -1 | null | false | false | false | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The target stays flat while the measurement falls. The command stays flat. Answer: normal |
21.03/test3/20200713T151843/P2-SC | 21.03/test3/20200713T151843 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:18:43 | P2-SC | normal | null | false | -1 | -1 | null | false | false | false | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T151843/P3-LC | 21.03/test3/20200713T151843 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:18:43 | P3-LC | normal | null | false | -1 | -1 | null | false | false | false | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target stays flat while the measurement falls. The command stays flat. Answer: normal |
21.03/test3/20200713T151823/P1-PC | 21.03/test3/20200713T151823 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:18:23 | P1-PC | attack | A302 | false | 157 | 577 | 157-577 | false | false | true | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The measurement starts swinging from second 157 while the target stays flat. The first valve command falls with it. The second valve command rises after it. Change starts near second 157. Answer: attack |
21.03/test3/20200713T151823/P1-LC | 21.03/test3/20200713T151823 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:18:23 | P1-LC | normal | null | false | -1 | -1 | null | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The target stays flat while the measurement falls. The command rises. Answer: normal |
21.03/test3/20200713T151823/P1-FC | 21.03/test3/20200713T151823 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:18:23 | P1-FC | attack | A302 | false | 157 | 577 | 157-577 | false | false | true | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The command rises from second 161 while the target stays flat. The measurement falls after it. Change starts near second 157. Answer: attack |
21.03/test3/20200713T151823/P1-TC | 21.03/test3/20200713T151823 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:18:23 | P1-TC | normal | null | false | -1 | -1 | null | false | false | false | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The target stays flat while the measurement falls. The command stays flat. Answer: normal |
21.03/test3/20200713T151823/P2-SC | 21.03/test3/20200713T151823 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:18:23 | P2-SC | normal | null | false | -1 | -1 | null | false | false | true | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T151823/P3-LC | 21.03/test3/20200713T151823 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:18:23 | P3-LC | normal | null | false | -1 | -1 | null | false | false | true | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target stays flat while the measurement falls. The command stays flat. Answer: normal |
21.03/test3/20200713T151727/P1-PC | 21.03/test3/20200713T151727 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:17:27 | P1-PC | attack | A302 | false | 213 | 633 | 213-633 | false | false | true | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The measurement starts swinging from second 214 while the target stays flat. The first valve command falls with it. The second valve command rises after it. Change starts near second 213. Answer: attack |
21.03/test3/20200713T151727/P1-LC | 21.03/test3/20200713T151727 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:17:27 | P1-LC | normal | null | false | -1 | -1 | null | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The target stays flat while the measurement falls. The command stays flat. Answer: normal |
21.03/test3/20200713T151727/P1-FC | 21.03/test3/20200713T151727 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:17:27 | P1-FC | attack | A302 | false | 213 | 633 | 213-633 | false | false | true | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The command falls from second 217 while the target stays flat. The measurement falls after it. Change starts near second 213. Answer: attack |
21.03/test3/20200713T151727/P1-TC | 21.03/test3/20200713T151727 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:17:27 | P1-TC | normal | null | false | -1 | -1 | null | false | false | false | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The target stays flat while the measurement falls. The command stays flat. Answer: normal |
21.03/test3/20200713T151727/P2-SC | 21.03/test3/20200713T151727 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:17:27 | P2-SC | normal | null | false | -1 | -1 | null | false | false | false | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T151727/P3-LC | 21.03/test3/20200713T151727 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:17:27 | P3-LC | normal | null | false | -1 | -1 | null | false | false | false | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target and the measurement stay flat. The command stays flat. Answer: normal |
21.03/test3/20200713T151630/P1-PC | 21.03/test3/20200713T151630 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:16:30 | P1-PC | attack | A302 | false | 270 | 690 | 270-690 | false | false | true | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The first valve command falls from second 272 while the target, measurement and second valve command stay flat. Change starts near second 270. Answer: attack |
21.03/test3/20200713T151630/P1-LC | 21.03/test3/20200713T151630 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:16:30 | P1-LC | normal | null | false | -1 | -1 | null | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The target and the measurement stay flat. The command stays flat. Answer: normal |
21.03/test3/20200713T151630/P1-FC | 21.03/test3/20200713T151630 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:16:30 | P1-FC | attack | A302 | false | 270 | 690 | 270-690 | false | false | true | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The command falls from second 274 while the target stays flat. The measurement falls after it. Change starts near second 270. Answer: attack |
21.03/test3/20200713T151630/P1-TC | 21.03/test3/20200713T151630 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:16:30 | P1-TC | normal | null | false | -1 | -1 | null | false | false | false | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The target and the measurement stay flat. The command stays flat. Answer: normal |
21.03/test3/20200713T151630/P2-SC | 21.03/test3/20200713T151630 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:16:30 | P2-SC | normal | null | false | -1 | -1 | null | false | false | false | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T151630/P3-LC | 21.03/test3/20200713T151630 | 21.03 | test3 | train | attack | A302 | false | 2020-07-13 15:16:30 | P3-LC | normal | null | false | -1 | -1 | null | false | false | true | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target and the measurement stay flat. The command stays flat. Answer: normal |
21.03/test3/20200713T181010/P1-PC | 21.03/test3/20200713T181010 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:10:10 | P1-PC | attack | A303 | false | 58 | 246 | 58-246 | false | false | true | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The measurement falls from second 58 while the target, first valve command and second valve command stay flat. Change starts near second 58. Answer: attack |
21.03/test3/20200713T181010/P1-LC | 21.03/test3/20200713T181010 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:10:10 | P1-LC | attack | A303 | false | 58 | 246 | 58-246 | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The measurement rises from second 58 while the target and command stay flat. Change starts near second 58. Answer: attack |
21.03/test3/20200713T181010/P1-FC | 21.03/test3/20200713T181010 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:10:10 | P1-FC | normal | null | false | -1 | -1 | null | false | true | false | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The target and the measurement stay flat. The command stays flat. Answer: normal |
21.03/test3/20200713T181010/P1-TC | 21.03/test3/20200713T181010 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:10:10 | P1-TC | normal | null | false | -1 | -1 | null | false | false | true | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The target and the measurement stay flat. The command falls. Answer: normal |
21.03/test3/20200713T181010/P2-SC | 21.03/test3/20200713T181010 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:10:10 | P2-SC | normal | null | false | -1 | -1 | null | false | false | true | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T181010/P3-LC | 21.03/test3/20200713T181010 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:10:10 | P3-LC | normal | null | false | -1 | -1 | null | false | false | true | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target and the measurement stay flat. The command stays flat. Answer: normal |
21.03/test3/20200713T180926/P1-PC | 21.03/test3/20200713T180926 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:09:26 | P1-PC | attack | A303 | false | 102 | 290 | 102-290 | false | false | true | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The measurement falls from second 102 while the target, first valve command and second valve command stay flat. Change starts near second 102. Answer: attack |
21.03/test3/20200713T180926/P1-LC | 21.03/test3/20200713T180926 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:09:26 | P1-LC | attack | A303 | false | 102 | 290 | 102-290 | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The measurement rises from second 102 while the target and command stay flat. Change starts near second 102. Answer: attack |
21.03/test3/20200713T180926/P1-FC | 21.03/test3/20200713T180926 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:09:26 | P1-FC | normal | null | false | -1 | -1 | null | false | true | false | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The target and the measurement stay flat. The command stays flat. Answer: normal |
21.03/test3/20200713T180926/P1-TC | 21.03/test3/20200713T180926 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:09:26 | P1-TC | normal | null | false | -1 | -1 | null | false | false | true | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The target and the measurement stay flat. The command falls. Answer: normal |
21.03/test3/20200713T180926/P2-SC | 21.03/test3/20200713T180926 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:09:26 | P2-SC | normal | null | false | -1 | -1 | null | false | false | false | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T180926/P3-LC | 21.03/test3/20200713T180926 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:09:26 | P3-LC | normal | null | false | -1 | -1 | null | false | false | false | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target and the measurement stay flat. The command stays flat. Answer: normal |
21.03/test3/20200713T180849/P1-PC | 21.03/test3/20200713T180849 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:08:49 | P1-PC | attack | A303 | false | 139 | 327 | 139-327 | false | false | true | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The measurement falls from second 139 while the target, first valve command and second valve command stay flat. Change starts near second 139. Answer: attack |
21.03/test3/20200713T180849/P1-LC | 21.03/test3/20200713T180849 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:08:49 | P1-LC | attack | A303 | false | 139 | 327 | 139-327 | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The measurement rises from second 139 while the target and command stay flat. Change starts near second 139. Answer: attack |
21.03/test3/20200713T180849/P1-FC | 21.03/test3/20200713T180849 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:08:49 | P1-FC | normal | null | false | -1 | -1 | null | false | true | false | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The target stays flat while the measurement starts swinging. The command falls. Answer: normal |
21.03/test3/20200713T180849/P1-TC | 21.03/test3/20200713T180849 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:08:49 | P1-TC | normal | null | false | -1 | -1 | null | false | false | true | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The target and the measurement stay flat. The command falls. Answer: normal |
21.03/test3/20200713T180849/P2-SC | 21.03/test3/20200713T180849 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:08:49 | P2-SC | normal | null | false | -1 | -1 | null | false | false | false | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T180849/P3-LC | 21.03/test3/20200713T180849 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:08:49 | P3-LC | normal | null | false | -1 | -1 | null | false | false | false | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target and the measurement stay flat. The command stays flat. Answer: normal |
21.03/test3/20200713T180800/P1-PC | 21.03/test3/20200713T180800 | 21.03 | test3 | train | attack | A303 | true | 2020-07-13 18:08:00 | P1-PC | attack | A303 | false | 188 | 376 | 188-376 | false | false | true | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The measurement falls from second 188 while the target, first valve command and second valve command stay flat. Change starts near second 188. Answer: attack |
21.03/test3/20200713T180800/P1-LC | 21.03/test3/20200713T180800 | 21.03 | test3 | train | attack | A303 | true | 2020-07-13 18:08:00 | P1-LC | attack | A303 | false | 188 | 376 | 188-376 | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The command rises from second 188 while the target stays flat. The measurement rises with it. Change starts near second 188. Answer: attack |
21.03/test3/20200713T180800/P1-FC | 21.03/test3/20200713T180800 | 21.03 | test3 | train | attack | A303 | true | 2020-07-13 18:08:00 | P1-FC | normal | null | false | -1 | -1 | null | false | true | false | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The target stays flat while the measurement rises. The command falls. Answer: normal |
21.03/test3/20200713T180800/P1-TC | 21.03/test3/20200713T180800 | 21.03 | test3 | train | attack | A303 | true | 2020-07-13 18:08:00 | P1-TC | normal | null | false | -1 | -1 | null | false | false | false | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The target stays flat while the measurement rises. The command falls. Answer: normal |
21.03/test3/20200713T180800/P2-SC | 21.03/test3/20200713T180800 | 21.03 | test3 | train | attack | A303 | true | 2020-07-13 18:08:00 | P2-SC | normal | null | false | -1 | -1 | null | false | false | false | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T180800/P3-LC | 21.03/test3/20200713T180800 | 21.03 | test3 | train | attack | A303 | true | 2020-07-13 18:08:00 | P3-LC | normal | null | false | -1 | -1 | null | false | false | false | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target and the measurement stay flat. The command rises. Answer: normal |
21.03/test3/20200713T180755/P1-PC | 21.03/test3/20200713T180755 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:07:55 | P1-PC | attack | A303 | false | 193 | 381 | 193-381 | false | false | true | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The measurement falls from second 193 while the target, first valve command and second valve command stay flat. Change starts near second 193. Answer: attack |
21.03/test3/20200713T180755/P1-LC | 21.03/test3/20200713T180755 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:07:55 | P1-LC | attack | A303 | false | 193 | 381 | 193-381 | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The command rises from second 193 while the target stays flat. The measurement rises with it. Change starts near second 193. Answer: attack |
21.03/test3/20200713T180755/P1-FC | 21.03/test3/20200713T180755 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:07:55 | P1-FC | normal | null | false | -1 | -1 | null | false | true | false | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The target stays flat while the measurement rises. The command falls. Answer: normal |
21.03/test3/20200713T180755/P1-TC | 21.03/test3/20200713T180755 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:07:55 | P1-TC | normal | null | false | -1 | -1 | null | false | false | true | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The target stays flat while the measurement rises. The command falls. Answer: normal |
21.03/test3/20200713T180755/P2-SC | 21.03/test3/20200713T180755 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:07:55 | P2-SC | normal | null | false | -1 | -1 | null | false | false | true | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T180755/P3-LC | 21.03/test3/20200713T180755 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:07:55 | P3-LC | normal | null | false | -1 | -1 | null | false | false | true | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target and the measurement stay flat. The command rises. Answer: normal |
21.03/test3/20200713T180649/P1-PC | 21.03/test3/20200713T180649 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:06:49 | P1-PC | attack | A303 | false | 259 | 447 | 259-447 | false | false | true | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | target measurement command command | P1_B2016 P1_PIT01 P1_PCV01D P1_PCV02D | same_name same_name same_name same_name | The measurement falls from second 259 while the target and second valve command stay flat. The first valve command falls after it. Change starts near second 259. Answer: attack |
21.03/test3/20200713T180649/P1-LC | 21.03/test3/20200713T180649 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:06:49 | P1-LC | attack | A303 | false | 259 | 447 | 259-447 | false | false | true | P1_B3004 P1_LIT01 P1_LCV01D | target measurement command | P1_B3004 P1_LIT01 P1_LCV01D | same_name same_name same_name | The command rises from second 259 while the target stays flat. The measurement rises with it. Change starts near second 259. Answer: attack |
21.03/test3/20200713T180649/P1-FC | 21.03/test3/20200713T180649 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:06:49 | P1-FC | normal | null | false | -1 | -1 | null | false | false | false | P1_B3005 P1_FT03 P1_FCV03D | target measurement command | P1_B3005 P1_FT03 P1_FCV03D | same_name same_name same_name | The target and the measurement stay flat. The command stays flat. Answer: normal |
21.03/test3/20200713T180649/P1-TC | 21.03/test3/20200713T180649 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:06:49 | P1-TC | normal | null | false | -1 | -1 | null | false | false | false | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | target target measurement command command | P1_B4022 P1_B4002 P1_TIT01 P1_FCV01D P1_FCV02D | same_name same_name same_name same_name same_name | The target stays flat while the measurement rises. The command stays flat. Answer: normal |
21.03/test3/20200713T180649/P2-SC | 21.03/test3/20200713T180649 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:06:49 | P2-SC | normal | null | false | -1 | -1 | null | false | false | true | P2_SIT01 P2_SCO | measurement command | P2_SIT01 P2_CO_rpm | same_name data | The measurement stays flat. The command stays flat. Answer: normal |
21.03/test3/20200713T180649/P3-LC | 21.03/test3/20200713T180649 | 21.03 | test3 | train | attack | A303 | false | 2020-07-13 18:06:49 | P3-LC | normal | null | false | -1 | -1 | null | false | false | false | P3_LH01 P3_LL01 P3_LIT01 P3_LCP01D P3_LCV01D | target target measurement command command | P3_LH P3_LL P3_LIT01 P3_LCP01D P3_LCV01D | name name same_name same_name same_name | The target and the measurement stay flat. The commands move. Answer: normal |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.