Datasets:

ArXiv:
License:
Open-H-RF / us4us /README.md
wsimson's picture tristan-deep's picture swpenninga's picture
OpenH-RF early access
bc70d9d
|
Raw History Blame
3.61 kB
---
pretty_name: "OpenH-RF — us4us Ring-Array USCT (forearm, breast phantom, water)"
license: cc-by-4.0
task_categories:
- other
tags:
- ultrasound
- rf
- openh-rf
- zea
- usct
- tomography
- ring-array
- attenuation
- forearm
language:
- en
size_categories:
- n<1K
---
## Dataset Description
Raw RF data acquired with the us4us Ltd. us4R system and a Draminski ring probe.
Intended for ultrasound tomographic reconstruction.
Acquisitions were performed on:
- the left and right human forearms of 8 healthy volunteers,
- a Yezitronix B-RG-1.2 breast phantom,
- a single reference slice from water only.
The forearm and phantom acquisitions comprise consecutive slices spaced 9 mm apart in depth (half of the probe elevation).
Each slice was recorded using 1024 subsequent single-element transmissions, and received by a 512-element aperture located opposite the transmitting element.
## Dataset Contributors
PI: Ziemowit Klimonda
Team: Piotr Jarosik, Jakub Rozbicki, Piotr Karwat, Marcin Lewandowski (all @ us4us Ltd. (https://us4us.eu/))
## Dataset Creation Date
09/07/2026
## License
CC BY 4.0
## Intended Usage
Ultrasound computed tomography image reconstruction.
## Dataset Characterization
* Data Collection Method: phantom, healthy adult human volunteers.
* Labeling Method: N/A.
* Acquisition system:
- ring probe:
- probe radius: 130mm,
- number of elements: 1024,
- center frequency: 2MHz,
- sampling rate: 8125000.0,
- us4R research system + host PC,
- custom positioning system for subject spatial control.
* Tx/Rx scheme:
- the scheme consisted of 1024 transmit-receive events,
- each event consisted of a single probe element transmitting a short pulse (1 period at 2 MHz excitation), while 512 probe elements were used for reception,
- the 1024 transmit events were performed sequentially, with each probe element transmitting once,
- for each transmission, the center of the receiving aperture was positioned on the opposite side of the probe relative to the transmitting element,
- for example, for the 0th transmission, the 0th probe element transmitted, and the receiving aperture consisted of probe elements 256–767.
## Dataset Format
All sub-datasets are provided in the ZEA file format.
No preprocessing was performed on the raw channel data.
## Dataset Quantification
**Current OpenH-RF release:** 18 HDF5 files; 32.66 GB (32,658,423,808 bytes) stored; root `zea_version` **0.1.6**. Sizes include all HDF5 contents and use decimal units (MB = 10^6 bytes, GB = 10^9 bytes, TB = 10^12 bytes), not decoded-array memory or original-source download sizes.
* Each HDF5 file contains 10 slices of the subject, except `reference_water.hdf5`, which contains a single slice.
* Stored HDF5 file sizes vary: 1.89 GB to 1.95 GB excluding the water reference. `reference_water.hdf5` is 183,107,584 bytes (183.11 MB).
## Subject Metadata
The dataset contains data from:
* breast phantom Yezitronix B-RG-1.2,
* both forearms of 8 healthy human volunteers (2 females and 6 males, age range [20, 55]),
* water only (reference data).
## Data Validation
* The data files contain attenuation sinograms and images reconstructed from raw data using the filtered backprojection algorithm.
## Known Issues
* The following probe elements should be considered damaged: [367, 409, 457, 764, 775, 776, 368, 390, 470, 739, 792].
## Ethical Considerations
* All human subjects were healthy adults who voluntarily participated in the measurements.