| pretty_name: "OpenH-RF — UBC Module C Fetal Phantom" | |
| license: cc-by-4.0 | |
| task_categories: | |
| - image-to-image | |
| tags: | |
| - ultrasound | |
| - rf | |
| - b-mode | |
| - beamforming | |
| - fetal-imaging | |
| - phantom | |
| - synthetic | |
| - multimodal | |
| - timeseries | |
| - video | |
| - openh-rf | |
| language: | |
| - en | |
| size_categories: | |
| - "1K<n<10K" | |
| # UBC Module C | |
| ## Dataset Description | |
| This dataset contains **3,845 two-dimensional ultrasound frames from two | |
| sessions** with the Kyoto Kagaku Fetus Ultrasound Examination Phantom | |
| “SPACE FAN-ST.” Each frame contains **synthetic RF channel data**, preserved | |
| beamformed IQ, a source-derived B-mode reference, and relative-time links to | |
| NDI tracking, BK scanner viewport video, and Intel RealSense video. | |
| The RF channels were simulated from already beamformed and compounded BK3500 | |
| IQ using a custom scatterer model and assumed transmit/receive geometry. They | |
| are not measured pre-beamforming channels. Modalities have temporal | |
| synchronization only; no validated spatial registration is supplied. | |
| ## Dataset Contributors | |
| - **Organization:** The University of British Columbia (UBC), Department of | |
| Electrical and Computer Engineering and School of Biomedical Engineering. | |
| - **Dataset-preparation contact:** Zongze Li, zongze@student.ubc.ca. | |
| - **Contributors:** Septimiu E. Salcudean, Robert Rohling, Qi Zeng, | |
| Tajwar Abrar Aleef, Hamid Moradi, Mohammad Honarvar, Wanwen Chen, Zijian Wu, | |
| Yuxin Chen, Yu Chung Lee, Zongze Li, Patrick Boyan Chen, and Michael Frew. | |
| ## Dataset Creation Date | |
| - **Physical phantom acquisition:** 06/12/2026. | |
| - **Release preparation:** 09/08/2026. | |
| ## License / Terms of Use | |
| The dataset is licensed under **Creative Commons Attribution 4.0 International | |
| (CC BY 4.0)** (https://creativecommons.org/licenses/by/4.0/). The HDF5 `metadata/credit` field carries | |
| the following attribution with the contributor names and contact listed above: | |
| > University of British Columbia OpenH-RF contributors (2026). *UBC Module C: | |
| > Synthetic Channel Proxy and Multimodal Fetal Phantom Ultrasound*. OpenH-RF. | |
| > CC BY 4.0. | |
| ## Intended Usage | |
| Research uses include synthetic RF-to-B-mode reconstruction, denoising, | |
| super-resolution, fetal-phantom scan-plane assessment, and temporally aligned | |
| multimodal learning. The dataset is for research and technical evaluation, | |
| not clinical diagnosis. Source-derived reference images are not independent | |
| physical ground truth for the simulated channels. | |
| ## Dataset Characterization | |
| - **Collection:** Phantom ultrasound and simultaneous room-camera and tracking | |
| recordings, followed by deterministic synthetic-channel generation. | |
| - **Acquisition system:** BK3500 ultrasound; NDI Tool-2 tracked-marker poses; | |
| NDI Tool-1 reference-tool poses; Intel RealSense RGB, left/right infrared, | |
| and encoded depth video. | |
| - **Labels:** Source indices, synchronization validity flags, and simulation | |
| provenance. No manual fetal-structure segmentations or verified phantom | |
| configuration labels are supplied. | |
| - **Simulation framework:** Custom NumPy/SciPy scatterer forward model using | |
| four-point fractional delays, pulse filtering, frame-specific noise, and | |
| `int16` quantization. Session 1 preserves its original amplitudes and shared random draws, | |
| with scatterer depths evaluated on each frame's source IQ axial grid. Session 2 uses fixed | |
| deterministic positions and reflectivity draws for the session, with | |
| frame amplitudes derived from its IQ envelope. | |
| No two-channel proxy data are included as equivalent RF measurements. | |
| ### Ultrasound and synthetic-channel parameters | |
| | Parameter | Value | Status | | |
| |---|---:|---| | |
| | Frames | 3,845 | Two sessions; one per matched BK/RealSense frame | | |
| | Focused transmit events per frame | 248 | Stored in each zea file | | |
| | Receive elements | 192 | Synthetic assumption | | |
| | Axial RF samples per trace | 3,153 | Includes 300 zero-tail samples | | |
| | RF components | 1 real component | Stored as `int16` | | |
| | Sampling frequency | 15 MHz | Stored zea scan parameter | | |
| | Center/demodulation frequency | 3.75 MHz | Stored zea scan parameter | | |
| | Assumed sound speed | 1,540 m/s | Stored zea scan parameter | | |
| | Assumed element pitch | 0.2 mm | Synthetic geometry assumption | | |
| | Assumed nominal aperture | 38.4 mm | 192 elements × 0.2 mm | | |
| | Element width / height | 0.18 mm / 5.0 mm | Synthetic model | | |
| | Assumed transmit focus | 98 mm | Copied from source scan metadata | | |
| | RF trace duration | 210.2 µs | Stored raw-data attribute | | |
| | Zero-amplitude tail | 20 µs / 300 samples | Stored raw-data attributes | | |
| | Target maximum magnitude | 26,000 counts | Below `int16` full scale | | |
| The element geometry and dimensions are simulation assumptions, not measured | |
| probe specifications. The relationship between the recorded 98-mm focus and | |
| the proprietary scanner transmit law is unknown. | |
| ## Dataset Format | |
| Each zea HDF5 file contains one frame and is written with **zea 0.1.5**. | |
| The writer-version field describes serialization, | |
| not processing speed. Source IQ and its display reference are under | |
| `/custom/source_provenance`. | |
| ### Package layout | |
| | Path | Contents | | |
| |---|---| | |
| | `acquisitions/session_01/session_01_fNNNN.hdf5` | Selected source frames 0055–2586; gaps are intentional | | |
| | `acquisitions/session_02/session_02_fNNNN.hdf5` | Selected source frames 0001–5017; gaps are intentional | | |
| | `source_bmode/session_XX/` | BK viewport MP4 video | | |
| | `external_camera/session_XX/` | RealSense MP4 video | | |
| | [`pipeline.yaml`](pipeline.yaml) | Shared reconstruction configuration for both sessions | | |
| `session_XX` denotes `session_01` or `session_02`. All public identifiers are | |
| neutral session labels. HDF5 `source_file` values identify private source | |
| container aliases, not downloadable package files; the source IQ is embedded | |
| in each sample. This HF release includes HDF5 files, this card, the pipeline | |
| configuration, and the source BK viewport and RealSense MP4 videos. | |
| Composite review videos, standalone scripts, timing/tracking tables, | |
| calibration sidecars, and validation reports are not included. References | |
| inside unchanged HDF5 metadata may identify sidecars from the source package | |
| that are not available in this release. | |
| ### Timestamp conventions | |
| **All acquisition timestamps are session-relative. Absolute wall-clock times | |
| are intentionally withheld for de-identification.** IQ, BK viewport, NDI | |
| reference-tool, and RealSense host times are relative to the first **source** IQ | |
| frame of their own session, even when that frame is excluded from the release. RealSense device time is relative to its first camera frame. | |
| Negative host-relative camera times can precede the first IQ frame. | |
| Each one-frame zea probe-pose timestamp is locally zero, with session-relative | |
| IQ time stored separately in `/custom/synchronization`. | |
| Use alignment indices and validity flags, not video frame rate alone, to link | |
| modalities. The HDF5 Tool-2 previous/next/recorded-last indices address the | |
| **status-zero subset** of the source tracking records. Tool-1 reference | |
| indices address the full source reference-tool records. These standalone | |
| tables are not included in this HF release. MP4 playback time is an encoded | |
| presentation timeline, not an acquisition clock; use the per-frame | |
| synchronization metadata retained in HDF5. | |
| ## Dataset Quantification | |
| | Quantity | session_01 | session_02 | Total | | |
| |---|---:|---:|---:| | |
| | Retained ultrasound frames / HDF5 files | 1,339 | 2,506 | 3,845 | | |
| | Original ultrasound frames | 2,613 | 5,019 | 7,632 | | |
| | Excluded unmatched or repeated video associations | 1,274 | 2,513 | 3,787 | | |
| | Retained source frame range (with gaps) | 55–2586 | 1–5017 | Original frame numbers preserved | | |
| | Retained IQ time span (s) | 1.063–52.681 | 0.018–93.757 | Separate source-session origins | | |
| | BK viewport video frames | 1,582 | 2,798 | 4,380 | | |
| | Frames per RealSense stream | 1,591 | 3,677 | 5,268 | | |
| | Valid BK / NDI Tool-2 / NDI Tool-1 / RealSense links | 1,339 each | 2,506 each | 3,845 each | | |
| **Frame selection:** Every retained ultrasound frame has a valid BK video link, | |
| RealSense video link, interpolated NDI Tool-2 pose, and NDI Tool-1 reference | |
| link. Each BK frame and each RealSense frame is associated with **at most one** | |
| retained ultrasound frame. Selection maximizes the number of chronological | |
| matches, then minimizes the sum of absolute BK/RealSense timing offsets; source | |
| frame order breaks remaining ties. Original frame indices, relative times, and | |
| noise seeds are preserved. HDF5 files contain only retained ultrasound frames; | |
| videos retain their full temporal context. | |
| **HDF5 storage:** session_01: 205,236,518,547 bytes (191.14 GiB); session_02: 388,206,776,234 bytes (361.55 GiB). Total: **593,443,294,781 bytes (552.69 GiB)**. Files use lossless compression. | |
| **Splits:** None supplied. Neighboring frames and the two sessions share a | |
| phantom and acquisition setting. Split by session for temporal separation; | |
| this does not establish generalization to different phantoms or patients. | |
| ### Per-sample feature table | |
| | Name | Shape | Dtype | Units | Description | | |
| |---|---:|---|---|---| | |
| | `/tracks/track_0/data/raw_data` | `(1, 248, 3153, 192, 1)` | `int16` | scaled ADC-like counts | Synthetic real-RF channel tensor ordered as frame, transmit, axial sample, receive element, RF component | | |
| | `/tracks/track_0/data/image/values` | `(1, 704, 248, 1)` | `uint8` | display gray level | Stored source-derived reference image; not used as a reconstruction input | | |
| | `/tracks/track_0/data/image/coordinates` | `(704, 248, 3)` | `float32` | m | Cartesian coordinate for each stored reference-image pixel | | |
| | `/probe/probe_geometry` | `(192, 3)` | `float32` | m | Assumed synthetic receive-element positions | | |
| | `/tracks/track_0/scan/tx_apodizations` | `(248, 192)` | `float32` | unitless | Assumed transmit apodization per event and element | | |
| | `/tracks/track_0/scan/t0_delays` | `(248, 192)` | `float32` | s | Assumed transmit delay per event and element | | |
| | `/tracks/track_0/scan/transmit_origins` | `(248, 3)` | `float32` | m | Transmit-beam origins | | |
| | `/tracks/track_0/scan/focus_distances` | `(248,)` | `float32` | m | Focus distance for each transmit event | | |
| | `/tracks/track_0/scan/azimuth_angles` | `(248,)` | `float32` | rad | Azimuth angle for each scanline | | |
| | `/tracks/track_0/scan/initial_times` | `(248,)` | `float32` | s | ADC start time for each transmit event | | |
| | `/tracks/track_0/scan/tgc_gain_curve` | `(3153,)` | `float32` | unitless | Stored time-gain-compensation curve | | |
| | `/metadata/probe_pose/translation` | `(1, 3)` | `float32` | m | Interpolated NDI Tool-2 marker translation; not a calibrated probe-tip pose | | |
| | `/metadata/probe_pose/rotation` | `(1, 4)` | `float32` | unitless | NDI Tool-2 marker quaternion in `xyzw` order | | |
| | `/metadata/probe_pose/timestamps` | `(1,)` | `float32` | s | Locally rebased one-frame pose time; session-relative IQ time is stored separately | | |
| | `/custom/source_provenance/source_beamformed_iq` | `(N_IQ, 248, 2)` | `float32` | arbitrary | Preserved source beamformed and compounded IQ; axial sample count varies by frame | | |
| | `/custom/source_provenance/source_bmode_normalized` | `(704, 248)` | `float32` | normalized intensity | Source IQ envelope displayed over −50 to 0 dB | | |
| | `/custom/source_provenance/imaging_depth_m` | `()` | `float32` | m | 0.14-m depth read by reconstruction | | |
| | `/custom/simulation/scatterer_positions` | `(95232, 3)` | `float32` | m | Synthetic coordinates; source-grid-dependent in session 1, fixed across session 2 | | |
| | `/custom/simulation/scatterer_magnitudes` | `(95232,)` | `float32` | arbitrary | Signed synthetic scatterer magnitudes | | |
| | `/custom/simulation/simulation_settings` | `(11,)` | `float64` | mixed | Element, transmit, scatterer, aperture, focus, timing, scaling, and seed settings; ordering is documented in the dataset attribute | | |
| | `/custom/synchronization/*` | scalar or small vector | mixed | s, ms, rad, m, index, or unitless | Relative-time frame links, validity flags, NDI poses, source-frame fields, and deterministic simulation seeds | | |
| | `/custom/session_calibration/image_t_tracker` | `(4, 4)` | `float64` | translation in mm; linear-block units unconfirmed | Source-supplied transform; direction and spatial registration unconfirmed | | |
| `N_IQ` is 1,824, 1,840, or 1,888, as recorded per frame in | |
| `/custom/synchronization/source_valid_axial_samples`. The synthetic RF tensor | |
| has a fixed 3,153 axial samples regardless of source IQ length. | |
| Scalar zea fields additionally store the 15-MHz sampling frequency, 3.75-MHz | |
| center and demodulation frequencies, and 1,540-m/s sound speed. Dataset-level | |
| attributes provide descriptions and units for individual fields. | |
| ### Camera representation and calibration | |
| RGB and left/right IR are privacy crops, independently reviewed for each | |
| session: `x=320, y=200, width=720, height=520` from 1280 × 720 source frames. | |
| All source frames and their order are retained at 30 encoded fps. Crop-adjusted | |
| principal points satisfy `cx_crop = cx_source − 320` and | |
| `cy_crop = cy_source − 200`; focal lengths, distortion coefficients, and | |
| inter-camera extrinsics are unchanged. Depth remains an uncropped encoded | |
| preview. Standalone calibration and crop-check sidecars are not included in | |
| this HF release. | |
| ## Data Validation | |
| ### Reconstruction | |
| The contributor reports validation with Python 3.12, zea 0.1.5, and a | |
| CUDA 12.8 / PyTorch configuration. The retained `pipeline.yaml` records the | |
| shared reconstruction configuration; the standalone reconstruction entry | |
| point and its dependency file are not included in this HF release. | |
| The contributor's reconstruction reads synthetic `raw_data`, zea scan/probe parameters, and | |
| imaging depth. zea's native aligned scanline DAS uses exactly one transmit per | |
| scanline, followed by envelope detection, normalization, log compression, and | |
| the documented display conversion. Source IQ, stored B-mode, and videos are | |
| not reconstruction inputs. Prepared pipelines are reused only for matching | |
| scan/probe parameters and precision/device settings. | |
| The contributor's mixed-precision qualification compares against float32, | |
| using float32 if scanline RMSE exceeds 0.001 dB or maximum difference exceeds | |
| 0.05 dB. This describes the contributor's validation, not a runnable command | |
| included in this release. The contributor reports reconstruction of 90 frames | |
| across the two sessions, with four endpoints shared with a six-frame precision | |
| comparison. This does not imply that every RF file has been reconstructed. | |
| ### Software references | |
| - Harris, C. R., et al. (2020). [Array programming with NumPy](https://doi.org/10.1038/s41586-020-2649-2). *Nature*, 585, 357–362. | |
| - Virtanen, P., et al. (2020). [SciPy 1.0: fundamental algorithms for scientific computing in Python](https://doi.org/10.1038/s41592-019-0686-2). *Nature Methods*, 17, 261–272. | |
| - Stevens, T. S. W., et al. (2026). [zea: A Toolbox for Cognitive Ultrasound Imaging](https://doi.org/10.21105/joss.09881). *Journal of Open Source Software*, 11(121), 9881. See also the [zea operations documentation](https://zea.readthedocs.io/en/stable/_autosummary/zea.ops.html). | |
| ## Subject Metadata | |
| - **Subject type:** Phantom; no human patient or animal subject. | |
| - **Phantom:** Kyoto Kagaku Fetus Ultrasound Examination Phantom “SPACE FAN-ST.” | |
| - **Stable HDF5 subject ID:** `Kyoto-Kagaku-SPACE-FAN-ST` in both sessions. | |
| - **Sessions:** `session_01` and `session_02`, recorded separately from subject ID. | |
| - **Anatomical region:** Fetal ultrasound training phantom within an abdominal model. | |
| - **Demographics/pathology:** Not applicable. No verified phantom configuration label. | |
| ## Known Issues | |
| - **Synthetic provenance:** Already beamformed IQ cannot recover original | |
| element-level receive signals. RF and source-derived B-mode share source | |
| information; similarity is not independent physical validation. | |
| - **Unverified acquisition geometry:** The synthetic geometry is assumed. | |
| Scanner transmit law, receive aperture, RF time-zero, and proprietary | |
| compound/multibeam processing are unavailable. | |
| - **Display approximation:** Scan conversion uses a 31.1-mm display aperture, | |
| ±14.96° scanline range, virtual apex, and 4% black border. This differs from | |
| the 38.4-mm synthetic receive aperture and does not alter DAS delays. | |
| - **Spatial registration:** Probe/tool poses and ultrasound/cameras are | |
| **temporally synchronized only, not spatially registered**. The source-supplied | |
| `image_t_tracker` matrix has an **unconfirmed transform direction**. No | |
| camera-to-NDI or camera-to-ultrasound transform, calibrated probe-tip mapping, | |
| or phantom-anatomical registration is supplied. NDI axis interpretation is | |
| unverified. RealSense inter-camera calibration does not establish those mappings. | |
| - **Camera encoding:** RGB/IR are lossy H.264 crops. Depth is an H.264 display | |
| preview, not lossless metric Z16 depth. | |
| - **Identical infrared views:** Within each session, source IR-left/right are | |
| byte-identical, as are their cropped derivatives. They are not independent | |
| stereo views; supplied stereo extrinsics do not resolve this source limitation. | |
| ## Ethical Considerations | |
| Ultrasound content is phantom and simulation data, with no patient records, | |
| demographics, or animal subjects. Patient consent, human-subject IRB approval, | |
| and animal-welfare review are not applicable to that content. | |
| Room-camera recordings originally captured people. Released RGB/IR crops | |
| retain hands/forearms but exclude faces and the wider room. Uncropped RGB/IR, | |
| audio, original source identifiers, absolute acquisition clocks, and local | |
| filesystem paths are excluded. The camera review fully decoded all ten retained streams, inspected | |
| 48 distributed frames per stream, and reviewed every face-detector hit. | |
| The contributor reports that the reviewed hits were false positives and no | |
| faces were visible in the crops. The underlying review records are not | |
| included in this HF release. | |