Dataset Viewer
Auto-converted to Parquet Duplicate
applies_to
stringlengths
5
179
derived_fields
listlengths
3
3
id
stringlengths
23
60
paragraph
stringlengths
14
20
regulation_section
stringclasses
8 values
requirement_id
stringlengths
23
60
requirement_type
stringlengths
11
46
source
stringclasses
1 value
source_quote
stringlengths
72
785
url
stringlengths
89
126
value_imperial
stringlengths
6
103
value_metric
stringlengths
4
8
⌀
verified_fields
listlengths
3
5
stay_or_limitation
stringclasses
1 value
scaffold platforms
[ "paragraph", "requirement_id", "requirement_type" ]
access-required-trigger-height
1926.451(e)(1)
Access
access-required-trigger-height
trigger height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from anothe...
https://referencesource.org/osha-scaffold-dimensional-tolerances/access-required-trigger-height/
2 feet
0.6 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Each employee on a crawling board (chicken ladder)
[ "paragraph", "requirement_id", "requirement_type" ]
crawling-board-grabline-minimum-diameter
1926.451(g)(1)(iii)
Fall protection
crawling-board-grabline-minimum-diameter
minimum diameter
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(iii) Each employee on a crawling board (chicken ladder) shall be protected by a personal fall arrest system, a guardrail system (with minimum 200 pound toprail capacity), or by a three-fourth inch (1.9 cm) diameter grabline or equivalent handhold securely fastened beside each crawling board;
https://referencesource.org/osha-scaffold-dimensional-tolerances/crawling-board-grabline-minimum-diameter/
three-fourth inch
1.9 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Crossbracing is acceptable in place of a midrail
[ "paragraph", "requirement_id", "requirement_type" ]
crossbrace-as-midrail-maximum-crossing-height
1926.451(g)(4)(xv)
Fall protection
crossbrace-as-midrail-maximum-crossing-height
maximum height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(xv) Crossbracing is acceptable in place of a midrail when the crossing point of two braces is between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The end points at each...
https://referencesource.org/osha-scaffold-dimensional-tolerances/crossbrace-as-midrail-maximum-crossing-height/
30 inches
0.8 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Crossbracing is acceptable in place of a midrail
[ "paragraph", "requirement_id", "requirement_type" ]
crossbrace-as-midrail-minimum-crossing-height
1926.451(g)(4)(xv)
Fall protection
crossbrace-as-midrail-minimum-crossing-height
minimum height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(xv) Crossbracing is acceptable in place of a midrail when the crossing point of two braces is between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The end points at each...
https://referencesource.org/osha-scaffold-dimensional-tolerances/crossbrace-as-midrail-minimum-crossing-height/
20 inches
0.5 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform
[ "paragraph", "requirement_id", "requirement_type" ]
crossbrace-as-toprail-maximum-crossing-height
1926.451(g)(4)(xv)
Fall protection
crossbrace-as-toprail-maximum-crossing-height
maximum height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(xv) Crossbracing is acceptable in place of a midrail when the crossing point of two braces is between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The end points at each...
https://referencesource.org/osha-scaffold-dimensional-tolerances/crossbrace-as-toprail-maximum-crossing-height/
48 inches
1.3 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform
[ "paragraph", "requirement_id", "requirement_type" ]
crossbrace-as-toprail-minimum-crossing-height
1926.451(g)(4)(xv)
Fall protection
crossbrace-as-toprail-minimum-crossing-height
minimum height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(xv) Crossbracing is acceptable in place of a midrail when the crossing point of two braces is between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The end points at each...
https://referencesource.org/osha-scaffold-dimensional-tolerances/crossbrace-as-toprail-minimum-crossing-height/
38 inches
0.97 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
The end points at each upright
[ "paragraph", "requirement_id", "requirement_type" ]
crossbrace-end-point-maximum-spacing
1926.451(g)(4)(xv)
Fall protection
crossbrace-end-point-maximum-spacing
maximum spacing
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(xv) Crossbracing is acceptable in place of a midrail when the crossing point of two braces is between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The end points at each...
https://referencesource.org/osha-scaffold-dimensional-tolerances/crossbrace-end-point-maximum-spacing/
48 inches
1.3 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Direct access to or from another surface
[ "paragraph", "requirement_id", "requirement_type" ]
direct-access-maximum-horizontal-distance
1926.451(e)(8)
Access
direct-access-maximum-horizontal-distance
maximum distance
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(8) Direct access to or from another surface shall be used only when the scaffold is not more than 14 inches (36 cm) horizontally and not more than 24 inches (61 cm) vertically from the other surface.
https://referencesource.org/osha-scaffold-dimensional-tolerances/direct-access-maximum-horizontal-distance/
14 inches
36 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Direct access to or from another surface
[ "paragraph", "requirement_id", "requirement_type" ]
direct-access-maximum-vertical-distance
1926.451(e)(8)
Access
direct-access-maximum-vertical-distance
maximum distance
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(8) Direct access to or from another surface shall be used only when the scaffold is not more than 14 inches (36 cm) horizontally and not more than 24 inches (61 cm) vertically from the other surface.
https://referencesource.org/osha-scaffold-dimensional-tolerances/direct-access-maximum-vertical-distance/
24 inches
61 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
erecting or dismantling tubular welded frame scaffolds
[ "paragraph", "requirement_id", "requirement_type" ]
end-frame-climbing-maximum-vertical-spacing
1926.451(e)(9)(iii)
Access
end-frame-climbing-maximum-vertical-spacing
maximum spacing
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(iii) When erecting or dismantling tubular welded frame scaffolds, (end) frames, with horizontal members that are parallel, level and are not more than 22 inches apart vertically may be used as climbing devices for access, provided they are erected in a manner that creates a usable ladder and provides good hand hold an...
https://referencesource.org/osha-scaffold-dimensional-tolerances/end-frame-climbing-maximum-vertical-spacing/
22 inches
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Each employee on a scaffold
[ "paragraph", "requirement_id", "requirement_type" ]
fall-protection-trigger-height
1926.451(g)(1)
Fall protection
fall-protection-trigger-height
trigger height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level.
https://referencesource.org/osha-scaffold-dimensional-tolerances/fall-protection-trigger-height/
10 feet
3.1 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
float (ship) scaffolds
[ "paragraph", "requirement_id", "requirement_type" ]
float-scaffold-edging-minimum-dimensions
1926.451(h)(2)(ii)
Falling object protection
float-scaffold-edging-minimum-dimensions
permitted alternative dimensions
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ii) A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, except on float (ship) scaffolds where an edging of 3⁄4 × 11⁄2 inch (2 × 4 cm) wood or equivalent may be used in lieu of toeboards;
https://referencesource.org/osha-scaffold-dimensional-tolerances/float-scaffold-edging-minimum-dimensions/
3⁄4 × 11⁄2 inch
2 × 4 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Handrails, and toprails that are used as handrails
[ "paragraph", "requirement_id", "requirement_type" ]
handrail-minimum-clearance-from-objects
1926.451(e)(4)(vi)
Access
handrail-minimum-clearance-from-objects
minimum clearance
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(vi) Handrails, and toprails that are used as handrails, shall be at least 3 inches (7.6 cm) from other objects.
https://referencesource.org/osha-scaffold-dimensional-tolerances/handrail-minimum-clearance-from-objects/
3 inches
7.6 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1)
[ "paragraph", "requirement_id", "requirement_type" ]
height-to-base-ratio-tying-trigger
1926.451(c)(1)
Criteria for supported scaffolds
height-to-base-ratio-tying-trigger
height-to-base ratio trigger
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:
https://referencesource.org/osha-scaffold-dimensional-tolerances/height-to-base-ratio-tying-trigger/
four to one (4:1)
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
any scaffold hoist
[ "paragraph", "requirement_id", "requirement_type" ]
hoist-stall-load-maximum
1926.451(a)(5)
Capacity
hoist-stall-load-maximum
maximum load
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(5) The stall load of any scaffold hoist shall not exceed 3 times its rated load.
https://referencesource.org/osha-scaffold-dimensional-tolerances/hoist-stall-load-maximum/
3 times its rated load
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Hook-on and attachable ladders
[ "paragraph", "requirement_id", "requirement_type" ]
hook-on-ladder-bottom-rung-maximum-height
1926.451(e)(2)(ii)
Access
hook-on-ladder-bottom-rung-maximum-height
maximum height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ii) Hook-on and attachable ladders shall be positioned so that their bottom rung is not more than 24 inches (61 cm) above the scaffold supporting level;
https://referencesource.org/osha-scaffold-dimensional-tolerances/hook-on-ladder-bottom-rung-maximum-height/
24 inches
61 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Hook-on and attachable ladders
[ "paragraph", "requirement_id", "requirement_type" ]
hook-on-ladder-maximum-rung-spacing
1926.451(e)(2)(vi)
Access
hook-on-ladder-maximum-rung-spacing
maximum spacing
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(vi) Hook-on and attachable ladders shall have uniformly spaced rungs with a maximum spacing between rungs of 163⁄4 inches.
https://referencesource.org/osha-scaffold-dimensional-tolerances/hook-on-ladder-maximum-rung-spacing/
163⁄4 inches
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Hook-on and attachable ladders
[ "paragraph", "requirement_id", "requirement_type" ]
hook-on-ladder-minimum-rung-length
1926.451(e)(2)(v)
Access
hook-on-ladder-minimum-rung-length
minimum length
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(v) Hook-on and attachable ladders shall have a minimum rung length of 111⁄2 inches (29 cm); and
https://referencesource.org/osha-scaffold-dimensional-tolerances/hook-on-ladder-minimum-rung-length/
111⁄2 inches
29 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
hook-on and attachable ladders are used on a supported scaffold more than 35 feet (10.7 m) high
[ "paragraph", "requirement_id", "requirement_type" ]
hook-on-ladder-rest-platform-interval
1926.451(e)(2)(iii)
Access
hook-on-ladder-rest-platform-interval
maximum vertical interval
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(iii) When hook-on and attachable ladders are used on a supported scaffold more than 35 feet (10.7 m) high, they shall have rest platforms at 35-foot (10.7 m) maximum vertical intervals.
https://referencesource.org/osha-scaffold-dimensional-tolerances/hook-on-ladder-rest-platform-interval/
35-foot
10.7 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
intermediate members (such as balusters or additional rails)
[ "paragraph", "requirement_id", "requirement_type" ]
intermediate-member-maximum-spacing
1926.451(g)(4)(vi)
Fall protection
intermediate-member-maximum-spacing
maximum spacing
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(vi) When intermediate members (such as balusters or additional rails) are used, they shall not be more than 19 inches (48 cm) apart.
https://referencesource.org/osha-scaffold-dimensional-tolerances/intermediate-member-maximum-spacing/
19 inches
48 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
each scaffold and scaffold component
[ "paragraph", "requirement_id", "requirement_type" ]
load-safety-factor-scaffold-and-components
1926.451(a)(1)
Capacity
load-safety-factor-scaffold-and-components
load safety factor
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(1) Except as provided in paragraphs (a)(2) , (a)(3) , (a)(4) , (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.
https://referencesource.org/osha-scaffold-dimensional-tolerances/load-safety-factor-scaffold-and-components/
4 times the maximum intended load
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
the front edge of all platforms
[ "paragraph", "requirement_id", "requirement_type" ]
max-distance-to-work-face-general
1926.451(b)(3)
Scaffold platform construction
max-distance-to-work-face-general
maximum gap
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(3) Except as provided in paragraphs (b)(3) (i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this se...
https://referencesource.org/osha-scaffold-dimensional-tolerances/max-distance-to-work-face-general/
14 inches
36 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
outrigger scaffolds
[ "paragraph", "requirement_id", "requirement_type" ]
max-distance-to-work-face-outrigger
1926.451(b)(3)(i)
Scaffold platform construction
max-distance-to-work-face-outrigger
maximum gap
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(i) The maximum distance from the face for outrigger scaffolds shall be 3 inches (8 cm);
https://referencesource.org/osha-scaffold-dimensional-tolerances/max-distance-to-work-face-outrigger/
3 inches
8 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
plastering and lathing operations
[ "paragraph", "requirement_id", "requirement_type" ]
max-distance-to-work-face-plastering-lathing
1926.451(b)(3)(ii)
Scaffold platform construction
max-distance-to-work-face-plastering-lathing
maximum gap
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ii) The maximum distance from the face for plastering and lathing operations shall be 18 inches (46 cm).
https://referencesource.org/osha-scaffold-dimensional-tolerances/max-distance-to-work-face-plastering-lathing/
18 inches
46 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
guardrail systems with a minimum 100 pound toprail capacity
[ "paragraph", "requirement_id", "requirement_type" ]
midrail-minimum-strength-100-pound-systems
1926.451(g)(4)(ix)
Fall protection
midrail-minimum-strength-100-pound-systems
minimum strength
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ix) Midrails, screens, mesh, intermediate vertical members, solid panels, and equivalent structural members of a guardrail system shall be capable of withstanding, without failure, a force applied in any downward or horizontal direction at any point along the midrail or other member of at least 75 pounds (333 n) for g...
https://referencesource.org/osha-scaffold-dimensional-tolerances/midrail-minimum-strength-100-pound-systems/
75 pounds
333 n
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
guardrail systems with a minimum 200 pound toprail capacity
[ "paragraph", "requirement_id", "requirement_type" ]
midrail-minimum-strength-200-pound-systems
1926.451(g)(4)(ix)
Fall protection
midrail-minimum-strength-200-pound-systems
minimum strength
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ix) Midrails, screens, mesh, intermediate vertical members, solid panels, and equivalent structural members of a guardrail system shall be capable of withstanding, without failure, a force applied in any downward or horizontal direction at any point along the midrail or other member of at least 75 pounds (333 n) for g...
https://referencesource.org/osha-scaffold-dimensional-tolerances/midrail-minimum-strength-200-pound-systems/
150 pounds
666 n
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Each ladder jack scaffold, top plate bracket scaffold, roof bracket scaffold, and pump jack scaffold
[ "paragraph", "requirement_id", "requirement_type" ]
min-platform-width-bracket-and-jack-scaffolds
1926.451(b)(2)(i)
Scaffold platform construction
min-platform-width-bracket-and-jack-scaffolds
minimum width
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(i) Each ladder jack scaffold, top plate bracket scaffold, roof bracket scaffold, and pump jack scaffold shall be at least 12 inches (30 cm) wide. There is no minimum width requirement for boatswains' chairs. Note to paragraph (b)(2)(i): Pursuant to an administrative stay effective November 29, 1996 and published in th...
https://referencesource.org/osha-scaffold-dimensional-tolerances/min-platform-width-bracket-and-jack-scaffolds/
12 inches
30 cm
[ "applies_to", "regulation_section", "stay_or_limitation", "value_imperial", "value_metric" ]
Pursuant to an administrative stay effective November 29, 1996 and published in the Federal Register on November 25, 1996, the requirement in paragraph (b)(2)(i) that roof bracket scaffolds be at least 12 inches wide is stayed until November 25, 1997 or until rulemaking regarding the minimum width of roof bracket scaff...
each scaffold platform and walkway
[ "paragraph", "requirement_id", "requirement_type" ]
min-platform-width-general
1926.451(b)(2)
Scaffold platform construction
min-platform-width-general
minimum width
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.
https://referencesource.org/osha-scaffold-dimensional-tolerances/min-platform-width-general/
18 inches
46 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
mobile scaffold stairway-type ladders
[ "paragraph", "requirement_id", "requirement_type" ]
mobile-stairway-type-ladder-minimum-step-width
1926.451(e)(3)(iii)
Access
mobile-stairway-type-ladder-minimum-step-width
minimum width
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(3) Stairway-type ladders shall: (i) Be positioned such that their bottom step is not more than 24 inches (61 cm) above the scaffold supporting level; (ii) Be provided with rest platforms at 12 foot (3.7 m) maximum vertical intervals; (iii) Have a minimum step width of 16 inches (41 cm), except that mobile scaffold sta...
https://referencesource.org/osha-scaffold-dimensional-tolerances/mobile-stairway-type-ladder-minimum-step-width/
111⁄2 inches
30 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform)
[ "paragraph", "requirement_id", "requirement_type" ]
platform-gap-adjacent-units-and-uprights
1926.451(b)(1)(i)
Scaffold platform construction
platform-gap-adjacent-units-and-uprights
maximum gap
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is n...
https://referencesource.org/osha-scaffold-dimensional-tolerances/platform-gap-adjacent-units-and-uprights/
1 inch
2.5 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
the remaining open space between the platform and the uprights
[ "paragraph", "requirement_id", "requirement_type" ]
platform-gap-to-uprights-demonstrated-exception
1926.451(b)(1)(ii)
Scaffold platform construction
platform-gap-to-uprights-demonstrated-exception
maximum gap
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ii) Where the employer makes the demonstration provided for in paragraph (b)(1)(i) of this section, the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 91⁄2 inches (24.1 cm).
https://referencesource.org/osha-scaffold-dimensional-tolerances/platform-gap-to-uprights-demonstrated-exception/
91⁄2 inches
24.1 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Platforms
[ "paragraph", "requirement_id", "requirement_type" ]
platform-maximum-deflection
1926.451(f)(16)
Use
platform-maximum-deflection
maximum deflection
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(16) Platforms shall not deflect more than 1⁄60 of the span when loaded.
https://referencesource.org/osha-scaffold-dimensional-tolerances/platform-maximum-deflection/
1⁄60 of the span
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Each end of a platform 10 feet or less in length
[ "paragraph", "requirement_id", "requirement_type" ]
platform-overhang-maximum-10-feet-or-less
1926.451(b)(5)(i)
Scaffold platform construction
platform-overhang-maximum-10-feet-or-less
maximum overhang
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(i) Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access t...
https://referencesource.org/osha-scaffold-dimensional-tolerances/platform-overhang-maximum-10-feet-or-less/
12 inches
30 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Each platform greater than 10 feet in length
[ "paragraph", "requirement_id", "requirement_type" ]
platform-overhang-maximum-over-10-feet
1926.451(b)(5)(ii)
Scaffold platform construction
platform-overhang-maximum-over-10-feet
maximum overhang
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.
https://referencesource.org/osha-scaffold-dimensional-tolerances/platform-overhang-maximum-over-10-feet/
18 inches
46 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means
[ "paragraph", "requirement_id", "requirement_type" ]
platform-overhang-minimum
1926.451(b)(4)
Scaffold platform construction
platform-overhang-minimum
minimum overhang
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(4) Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm).
https://referencesource.org/osha-scaffold-dimensional-tolerances/platform-overhang-minimum/
6 inches
15 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
scaffolds where platforms are overlapped to create a long platform
[ "paragraph", "requirement_id", "requirement_type" ]
platform-overlap-minimum
1926.451(b)(7)
Scaffold platform construction
platform-overlap-minimum
minimum overlap
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(7) On scaffolds where platforms are overlapped to create a long platform, the overlap shall occur only over supports, and shall not be less than 12 inches (30 cm) unless the platforms are nailed together or otherwise restrained to prevent movement.
https://referencesource.org/osha-scaffold-dimensional-tolerances/platform-overlap-minimum/
12 inches
30 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
300 volts to 50 kv
[ "paragraph", "requirement_id", "requirement_type" ]
powerline-clearance-insulated-300-volts-to-50-kv
1926.451(f)(6)
Use
powerline-clearance-insulated-300-volts-to-50-kv
minimum clearance from insulated power lines
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
Insulated lines voltage | Minimum distance | Alternatives | Less than 300 volts | 3 feet (0.9 m) | | 300 volts to 50 kv | 10 feet (3.1m) |
https://referencesource.org/osha-scaffold-dimensional-tolerances/powerline-clearance-insulated-300-volts-to-50-kv/
10 feet
3.1m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
More than 50 kv
[ "paragraph", "requirement_id", "requirement_type" ]
powerline-clearance-insulated-over-50-kv
1926.451(f)(6)
Use
powerline-clearance-insulated-over-50-kv
minimum clearance from insulated power lines
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
Insulated lines voltage | Minimum distance | Alternatives | Less than 300 volts | 3 feet (0.9 m) | | 300 volts to 50 kv | 10 feet (3.1m) | | More than 50 kv | 10 feet (3.1 m) plus 0.4 inches (1.0 cm) for each 1 kv over 50 kv | 2 times the length of the line insulator, but never less than 10 feet (3.1 m). |
https://referencesource.org/osha-scaffold-dimensional-tolerances/powerline-clearance-insulated-over-50-kv/
10 feet (3.1 m) plus 0.4 inches (1.0 cm) for each 1 kv over 50 kv
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Less than 300 volts
[ "paragraph", "requirement_id", "requirement_type" ]
powerline-clearance-insulated-under-300-volts
1926.451(f)(6)
Use
powerline-clearance-insulated-under-300-volts
minimum clearance from insulated power lines
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
Insulated lines voltage | Minimum distance | Alternatives | Less than 300 volts | 3 feet (0.9 m) |
https://referencesource.org/osha-scaffold-dimensional-tolerances/powerline-clearance-insulated-under-300-volts/
3 feet
0.9 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
More than 50 kv
[ "paragraph", "requirement_id", "requirement_type" ]
powerline-clearance-uninsulated-over-50-kv
1926.451(f)(6)
Use
powerline-clearance-uninsulated-over-50-kv
minimum clearance from uninsulated power lines
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
Uninsulated lines voltage | Minimum distance | Alternatives | Less than 50 kv | 10 feet (3.1 m) | | More than 50 kv | 10 feet (3.1 m) plus 0.4 inches (1.0 cm) for each 1 kv over 50 kv | 2 times the length of the line insulator, but never less than 10 feet (3.1 m). |
https://referencesource.org/osha-scaffold-dimensional-tolerances/powerline-clearance-uninsulated-over-50-kv/
10 feet (3.1 m) plus 0.4 inches (1.0 cm) for each 1 kv over 50 kv
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Less than 50 kv
[ "paragraph", "requirement_id", "requirement_type" ]
powerline-clearance-uninsulated-under-50-kv
1926.451(f)(6)
Use
powerline-clearance-uninsulated-under-50-kv
minimum clearance from uninsulated power lines
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
Uninsulated lines voltage | Minimum distance | Alternatives | Less than 50 kv | 10 feet (3.1 m) |
https://referencesource.org/osha-scaffold-dimensional-tolerances/powerline-clearance-uninsulated-under-50-kv/
10 feet
3.1 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Integral prefabricated scaffold access frames
[ "paragraph", "requirement_id", "requirement_type" ]
prefabricated-access-frame-maximum-rung-spacing
1926.451(e)(6)(vi)
Access
prefabricated-access-frame-maximum-rung-spacing
maximum spacing
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(6) Integral prefabricated scaffold access frames shall: (i) Be specifically designed and constructed for use as ladder rungs; (ii) Have a rung length of at least 8 inches (20 cm); (iii) Not be used as work platforms when rungs are less than 111⁄2 inches in length, unless each affected employee uses fall protection, or...
https://referencesource.org/osha-scaffold-dimensional-tolerances/prefabricated-access-frame-maximum-rung-spacing/
163⁄4 inches
43 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Integral prefabricated scaffold access frames
[ "paragraph", "requirement_id", "requirement_type" ]
prefabricated-access-frame-minimum-rung-length
1926.451(e)(6)(ii)
Access
prefabricated-access-frame-minimum-rung-length
minimum length
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(6) Integral prefabricated scaffold access frames shall: (i) Be specifically designed and constructed for use as ladder rungs; (ii) Have a rung length of at least 8 inches (20 cm);
https://referencesource.org/osha-scaffold-dimensional-tolerances/prefabricated-access-frame-minimum-rung-length/
8 inches
20 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
all supported scaffolds more than 35 feet (10.7 m) high
[ "paragraph", "requirement_id", "requirement_type" ]
prefabricated-access-frame-rest-platform-interval
1926.451(e)(6)(v)
Access
prefabricated-access-frame-rest-platform-interval
maximum vertical interval
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(v) Be provided with rest platforms at 35-foot (10.7 m) maximum vertical intervals on all supported scaffolds more than 35 feet (10.7 m) high; and
https://referencesource.org/osha-scaffold-dimensional-tolerances/prefabricated-access-frame-rest-platform-interval/
35-foot
10.7 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Integral prefabricated scaffold access frames
[ "paragraph", "requirement_id", "requirement_type" ]
prefabricated-access-frame-work-platform-minimum-rung-length
1926.451(e)(6)(iii)
Access
prefabricated-access-frame-work-platform-minimum-rung-length
minimum length
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(6) Integral prefabricated scaffold access frames shall: (i) Be specifically designed and constructed for use as ladder rungs; (ii) Have a rung length of at least 8 inches (20 cm); (iii) Not be used as work platforms when rungs are less than 111⁄2 inches in length
https://referencesource.org/osha-scaffold-dimensional-tolerances/prefabricated-access-frame-work-platform-minimum-rung-length/
111⁄2 inches
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
the slope of a ramp or a walkway is steeper than one (1) vertical in eight (8) horizontal
[ "paragraph", "requirement_id", "requirement_type" ]
ramp-walkway-cleat-maximum-spacing
1926.451(e)(5)(iii)
Access
ramp-walkway-cleat-maximum-spacing
maximum spacing
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(iii) If the slope of a ramp or a walkway is steeper than one (1) vertical in eight (8) horizontal, the ramp or walkway shall have cleats not more than fourteen (14) inches (35 cm) apart which are securely fastened to the planks to provide footing.
https://referencesource.org/osha-scaffold-dimensional-tolerances/ramp-walkway-cleat-maximum-spacing/
fourteen (14) inches
35 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Ramps and walkways
[ "paragraph", "requirement_id", "requirement_type" ]
ramp-walkway-guardrail-trigger-height
1926.451(e)(5)(i)
Access
ramp-walkway-guardrail-trigger-height
trigger height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(i) Ramps and walkways 6 feet (1.8 m) or more above lower levels shall have guardrail systems which comply with subpart M of this part
https://referencesource.org/osha-scaffold-dimensional-tolerances/ramp-walkway-guardrail-trigger-height/
6 feet
1.8 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
ramp or walkway
[ "paragraph", "requirement_id", "requirement_type" ]
ramp-walkway-maximum-slope
1926.451(e)(5)(ii)
Access
ramp-walkway-maximum-slope
maximum slope
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ii) No ramp or walkway shall be inclined more than a slope of one (1) vertical to three (3) horizontal (20 degrees above the horizontal).
https://referencesource.org/osha-scaffold-dimensional-tolerances/ramp-walkway-maximum-slope/
one (1) vertical to three (3) horizontal (20 degrees above the horizontal)
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Ropes
[ "paragraph", "requirement_id", "requirement_type" ]
rope-replacement-broken-wires-per-rope-lay
1926.451(d)(10)(iii)
Criteria for suspension scaffolds
rope-replacement-broken-wires-per-rope-lay
replacement threshold
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(10) Ropes shall be inspected for defects by a competent person prior to each workshift and after every occurrence which could affect a rope's integrity. Ropes shall be replaced if any of the following conditions exist: (i) Any physical damage which impairs the function and strength of the rope. (ii) Kinks that might i...
https://referencesource.org/osha-scaffold-dimensional-tolerances/rope-replacement-broken-wires-per-rope-lay/
Six randomly distributed broken wires in one rope lay
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Ropes
[ "paragraph", "requirement_id", "requirement_type" ]
rope-replacement-broken-wires-per-strand
1926.451(d)(10)(iii)
Criteria for suspension scaffolds
rope-replacement-broken-wires-per-strand
replacement threshold
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(10) Ropes shall be inspected for defects by a competent person prior to each workshift and after every occurrence which could affect a rope's integrity. Ropes shall be replaced if any of the following conditions exist: (i) Any physical damage which impairs the function and strength of the rope. (ii) Kinks that might i...
https://referencesource.org/osha-scaffold-dimensional-tolerances/rope-replacement-broken-wires-per-strand/
three broken wires in one strand in one rope lay
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Ropes
[ "paragraph", "requirement_id", "requirement_type" ]
rope-replacement-outside-wire-diameter-loss
1926.451(d)(10)(iv)
Criteria for suspension scaffolds
rope-replacement-outside-wire-diameter-loss
replacement threshold
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(10) Ropes shall be inspected for defects by a competent person prior to each workshift and after every occurrence which could affect a rope's integrity. Ropes shall be replaced if any of the following conditions exist: (i) Any physical damage which impairs the function and strength of the rope. (ii) Kinks that might i...
https://referencesource.org/osha-scaffold-dimensional-tolerances/rope-replacement-outside-wire-diameter-loss/
more than one-third of the original diameter of the outside wires
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Each suspension rope, including connecting hardware, used on adjustable suspension scaffolds
[ "paragraph", "requirement_id", "requirement_type" ]
rope-safety-factor-adjustable-suspension
1926.451(a)(4)
Capacity
rope-safety-factor-adjustable-suspension
load safety factor
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(4) Each suspension rope, including connecting hardware, used on adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope with the scaffold operating at either the rated load of the hoist, or 2 (minimum) times the sta...
https://referencesource.org/osha-scaffold-dimensional-tolerances/rope-safety-factor-adjustable-suspension/
6 times the maximum intended load
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Each suspension rope, including connecting hardware, used on adjustable suspension scaffolds
[ "paragraph", "requirement_id", "requirement_type" ]
rope-safety-factor-adjustable-suspension-stall-load
1926.451(a)(4)
Capacity
rope-safety-factor-adjustable-suspension-stall-load
load safety factor
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(4) Each suspension rope, including connecting hardware, used on adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope with the scaffold operating at either the rated load of the hoist, or 2 (minimum) times the sta...
https://referencesource.org/osha-scaffold-dimensional-tolerances/rope-safety-factor-adjustable-suspension-stall-load/
2 (minimum) times the stall load of the hoist
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Each suspension rope, including connecting hardware, used on non-adjustable suspension scaffolds
[ "paragraph", "requirement_id", "requirement_type" ]
rope-safety-factor-non-adjustable-suspension
1926.451(a)(3)
Capacity
rope-safety-factor-non-adjustable-suspension
load safety factor
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(3) Each suspension rope, including connecting hardware, used on non-adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope.
https://referencesource.org/osha-scaffold-dimensional-tolerances/rope-safety-factor-non-adjustable-suspension/
6 times the maximum intended load
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Each scaffold stairway
[ "paragraph", "requirement_id", "requirement_type" ]
scaffold-stairway-minimum-width-between-stairrails
1926.451(e)(4)(ix)
Access
scaffold-stairway-minimum-width-between-stairrails
minimum width
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ix) Each scaffold stairway shall be at least 18 inches (45.7 cm) wide between stairrails.
https://referencesource.org/osha-scaffold-dimensional-tolerances/scaffold-stairway-minimum-width-between-stairrails/
18 inches
45.7 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
A landing platform
[ "paragraph", "requirement_id", "requirement_type" ]
stair-landing-platform-minimum-length
1926.451(e)(4)(viii)
Access
stair-landing-platform-minimum-length
minimum length
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(viii) A landing platform at least 18 inches (45.7 cm) wide by at least 18 inches (45.7 cm) long shall be provided at each level.
https://referencesource.org/osha-scaffold-dimensional-tolerances/stair-landing-platform-minimum-length/
18 inches
45.7 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
A landing platform
[ "paragraph", "requirement_id", "requirement_type" ]
stair-landing-platform-minimum-width
1926.451(e)(4)(viii)
Access
stair-landing-platform-minimum-width
minimum width
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(viii) A landing platform at least 18 inches (45.7 cm) wide by at least 18 inches (45.7 cm) long shall be provided at each level.
https://referencesource.org/osha-scaffold-dimensional-tolerances/stair-landing-platform-minimum-width/
18 inches
45.7 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Riser height
[ "paragraph", "requirement_id", "requirement_type" ]
stair-riser-height-maximum-variation
1926.451(e)(4)(xiii)
Access
stair-riser-height-maximum-variation
maximum variation
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(xiii) Riser height shall be uniform, within 1⁄4 inch, (0.6 cm) for each flight of stairs. Greater variations in riser height are allowed for the top and bottom steps of the entire system, not for each flight of stairs.
https://referencesource.org/osha-scaffold-dimensional-tolerances/stair-riser-height-maximum-variation/
1⁄4 inch
0.6 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Tread depth
[ "paragraph", "requirement_id", "requirement_type" ]
stair-tread-depth-maximum-variation
1926.451(e)(4)(xiv)
Access
stair-tread-depth-maximum-variation
maximum variation
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(xiv) Tread depth shall be uniform, within 1⁄4 inch, for each flight of stairs.
https://referencesource.org/osha-scaffold-dimensional-tolerances/stair-tread-depth-maximum-variation/
1⁄4 inch
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Stairrails
[ "paragraph", "requirement_id", "requirement_type" ]
stairrail-maximum-height
1926.451(e)(4)(vii)
Access
stairrail-maximum-height
maximum height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(vii) Stairrails shall be not less than 28 inches (71 cm) nor more than 37 inches (94 cm) from the upper surface of the stairrail to the surface of the tread, in line with the face of the riser at the forward edge of the tread.
https://referencesource.org/osha-scaffold-dimensional-tolerances/stairrail-maximum-height/
37 inches
94 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Stairrails
[ "paragraph", "requirement_id", "requirement_type" ]
stairrail-minimum-height
1926.451(e)(4)(vii)
Access
stairrail-minimum-height
minimum height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(vii) Stairrails shall be not less than 28 inches (71 cm) nor more than 37 inches (94 cm) from the upper surface of the stairrail to the surface of the tread, in line with the face of the riser at the forward edge of the tread.
https://referencesource.org/osha-scaffold-dimensional-tolerances/stairrail-minimum-height/
28 inches
71 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Stairtowers (scaffold stairway/towers)
[ "paragraph", "requirement_id", "requirement_type" ]
stairtower-bottom-step-maximum-height
1926.451(e)(4)
Access
stairtower-bottom-step-maximum-height
maximum height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(4) Stairtowers (scaffold stairway/towers) shall be positioned such that their bottom step is not more than 24 inches (61 cm.) above the scaffold supporting level.
https://referencesource.org/osha-scaffold-dimensional-tolerances/stairtower-bottom-step-maximum-height/
24 inches
61 cm.
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Stairways
[ "paragraph", "requirement_id", "requirement_type" ]
stairway-maximum-angle-from-horizontal
1926.451(e)(4)(xi)
Access
stairway-maximum-angle-from-horizontal
maximum angle
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(xi) Stairways shall be installed between 40 degrees and 60 degrees from the horizontal.
https://referencesource.org/osha-scaffold-dimensional-tolerances/stairway-maximum-angle-from-horizontal/
60 degrees
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Stairways
[ "paragraph", "requirement_id", "requirement_type" ]
stairway-minimum-angle-from-horizontal
1926.451(e)(4)(xi)
Access
stairway-minimum-angle-from-horizontal
minimum angle
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(xi) Stairways shall be installed between 40 degrees and 60 degrees from the horizontal.
https://referencesource.org/osha-scaffold-dimensional-tolerances/stairway-minimum-angle-from-horizontal/
40 degrees
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Stairway-type ladders
[ "paragraph", "requirement_id", "requirement_type" ]
stairway-type-ladder-bottom-step-maximum-height
1926.451(e)(3)(i)
Access
stairway-type-ladder-bottom-step-maximum-height
maximum height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(3) Stairway-type ladders shall: (i) Be positioned such that their bottom step is not more than 24 inches (61 cm) above the scaffold supporting level;
https://referencesource.org/osha-scaffold-dimensional-tolerances/stairway-type-ladder-bottom-step-maximum-height/
24 inches
61 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Stairway-type ladders
[ "paragraph", "requirement_id", "requirement_type" ]
stairway-type-ladder-minimum-step-width
1926.451(e)(3)(iii)
Access
stairway-type-ladder-minimum-step-width
minimum width
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(3) Stairway-type ladders shall: (i) Be positioned such that their bottom step is not more than 24 inches (61 cm) above the scaffold supporting level; (ii) Be provided with rest platforms at 12 foot (3.7 m) maximum vertical intervals; (iii) Have a minimum step width of 16 inches (41 cm), except that mobile scaffold sta...
https://referencesource.org/osha-scaffold-dimensional-tolerances/stairway-type-ladder-minimum-step-width/
16 inches
41 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Stairway-type ladders
[ "paragraph", "requirement_id", "requirement_type" ]
stairway-type-ladder-rest-platform-interval
1926.451(e)(3)(ii)
Access
stairway-type-ladder-rest-platform-interval
maximum vertical interval
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(3) Stairway-type ladders shall: (i) Be positioned such that their bottom step is not more than 24 inches (61 cm) above the scaffold supporting level; (ii) Be provided with rest platforms at 12 foot (3.7 m) maximum vertical intervals;
https://referencesource.org/osha-scaffold-dimensional-tolerances/stairway-type-ladder-rest-platform-interval/
12 foot
3.7 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
All suspension scaffold support devices, such as outrigger beams, cornice hooks, parapet clamps, and similar devices
[ "paragraph", "requirement_id", "requirement_type" ]
support-device-surface-factor-rated-load
1926.451(d)(1)
Criteria for suspension scaffolds
support-device-surface-factor-rated-load
load safety factor
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(1) All suspension scaffold support devices, such as outrigger beams, cornice hooks, parapet clamps, and similar devices, shall rest on surfaces capable of supporting at least 4 times the load imposed on them by the scaffold operating at the rated load of the hoist (or at least 1.5 times the load imposed on them by the...
https://referencesource.org/osha-scaffold-dimensional-tolerances/support-device-surface-factor-rated-load/
4 times the load imposed on them by the scaffold operating at the rated load of the hoist
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
All suspension scaffold support devices, such as outrigger beams, cornice hooks, parapet clamps, and similar devices
[ "paragraph", "requirement_id", "requirement_type" ]
support-device-surface-factor-stall-capacity
1926.451(d)(1)
Criteria for suspension scaffolds
support-device-surface-factor-stall-capacity
load safety factor
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(1) All suspension scaffold support devices, such as outrigger beams, cornice hooks, parapet clamps, and similar devices, shall rest on surfaces capable of supporting at least 4 times the load imposed on them by the scaffold operating at the rated load of the hoist (or at least 1.5 times the load imposed on them by the...
https://referencesource.org/osha-scaffold-dimensional-tolerances/support-device-surface-factor-stall-capacity/
1.5 times the load imposed on them by the scaffold at the stall capacity of the hoist
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Such guys, ties and braces
[ "paragraph", "requirement_id", "requirement_type" ]
tie-horizontal-spacing-maximum
1926.451(c)(1)(ii)
Criteria for supported scaffolds
tie-horizontal-spacing-maximum
maximum spacing
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).
https://referencesource.org/osha-scaffold-dimensional-tolerances/tie-horizontal-spacing-maximum/
30 feet
9.1 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
scaffolds 3 feet (0.91 m) wide or less
[ "paragraph", "requirement_id", "requirement_type" ]
tie-vertical-spacing-narrow-scaffolds
1926.451(c)(1)(ii)
Criteria for supported scaffolds
tie-vertical-spacing-narrow-scaffolds
maximum spacing
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 fe...
https://referencesource.org/osha-scaffold-dimensional-tolerances/tie-vertical-spacing-narrow-scaffolds/
20 feet
6.1 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
scaffolds greater than 3 feet (0.91 m) wide
[ "paragraph", "requirement_id", "requirement_type" ]
tie-vertical-spacing-wide-scaffolds
1926.451(c)(1)(ii)
Criteria for supported scaffolds
tie-vertical-spacing-wide-scaffolds
maximum spacing
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 fe...
https://referencesource.org/osha-scaffold-dimensional-tolerances/tie-vertical-spacing-wide-scaffolds/
26 feet
7.9 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Direct connections to roofs and floors, and counterweights used to balance adjustable suspension scaffolds
[ "paragraph", "requirement_id", "requirement_type" ]
tipping-moment-factor-rated-load
1926.451(a)(2)
Capacity
tipping-moment-factor-rated-load
load safety factor
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(2) Direct connections to roofs and floors, and counterweights used to balance adjustable suspension scaffolds, shall be capable of resisting at least 4 times the tipping moment imposed by the scaffold operating at the rated load of the hoist, or 1.5 (minimum) times the tipping moment imposed by the scaffold operating ...
https://referencesource.org/osha-scaffold-dimensional-tolerances/tipping-moment-factor-rated-load/
4 times the tipping moment imposed by the scaffold operating at the rated load of the hoist
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Direct connections to roofs and floors, and counterweights used to balance adjustable suspension scaffolds
[ "paragraph", "requirement_id", "requirement_type" ]
tipping-moment-factor-stall-load
1926.451(a)(2)
Capacity
tipping-moment-factor-stall-load
load safety factor
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(2) Direct connections to roofs and floors, and counterweights used to balance adjustable suspension scaffolds, shall be capable of resisting at least 4 times the tipping moment imposed by the scaffold operating at the rated load of the hoist, or 1.5 (minimum) times the tipping moment imposed by the scaffold operating ...
https://referencesource.org/osha-scaffold-dimensional-tolerances/tipping-moment-factor-stall-load/
1.5 (minimum) times the tipping moment imposed by the scaffold operating at the stall load of the hoist
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
Toeboards
[ "paragraph", "requirement_id", "requirement_type" ]
toeboard-maximum-clearance-above-walking-surface
1926.451(h)(4)(ii)
Falling object protection
toeboard-maximum-clearance-above-walking-surface
maximum clearance
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ii) At least three and one-half inches (9 cm) high from the top edge of the toeboard to the level of the walking/working surface. Toeboards shall be securely fastened in place at the outermost edge of the platform and have not more than 1⁄4 inch (0.7 cm) clearance above the walking/working surface. Toeboards shall be ...
https://referencesource.org/osha-scaffold-dimensional-tolerances/toeboard-maximum-clearance-above-walking-surface/
1⁄4 inch
0.7 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Toeboards
[ "paragraph", "requirement_id", "requirement_type" ]
toeboard-maximum-opening-size
1926.451(h)(4)(ii)
Falling object protection
toeboard-maximum-opening-size
maximum opening
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ii) At least three and one-half inches (9 cm) high from the top edge of the toeboard to the level of the walking/working surface. Toeboards shall be securely fastened in place at the outermost edge of the platform and have not more than 1⁄4 inch (0.7 cm) clearance above the walking/working surface. Toeboards shall be ...
https://referencesource.org/osha-scaffold-dimensional-tolerances/toeboard-maximum-opening-size/
one inch
2.5 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Toeboards
[ "paragraph", "requirement_id", "requirement_type" ]
toeboard-minimum-height
1926.451(h)(4)(ii)
Falling object protection
toeboard-minimum-height
minimum height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ii) At least three and one-half inches (9 cm) high from the top edge of the toeboard to the level of the walking/working surface. Toeboards shall be securely fastened in place at the outermost edge of the platform and have not more than 1⁄4 inch (0.7 cm) clearance above the walking/working surface. Toeboards shall be ...
https://referencesource.org/osha-scaffold-dimensional-tolerances/toeboard-minimum-height/
three and one-half inches
9 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
toeboards
[ "paragraph", "requirement_id", "requirement_type" ]
toeboard-minimum-strength
1926.451(h)(4)(i)
Falling object protection
toeboard-minimum-strength
minimum strength
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(4) Where used, toeboards shall be: (i) Capable of withstanding, without failure, a force of at least 50 pounds (222 n) applied in any downward or horizontal direction at any point along the toeboard (toeboards built in accordance with appendix A to this subpart will be deemed to meet this requirement); and
https://referencesource.org/osha-scaffold-dimensional-tolerances/toeboard-minimum-strength/
50 pounds
222 n
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
platforms more than 10 feet (3.1 m) above lower levels
[ "paragraph", "requirement_id", "requirement_type" ]
toeboard-trigger-height
1926.451(h)(2)(ii)
Falling object protection
toeboard-trigger-height
trigger height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ii) A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, except on float (ship) scaffolds where an edging of 3⁄4 × 11⁄2 inch (2 × 4 cm) wood or equivalent may be used in lieu of toeboards;
https://referencesource.org/osha-scaffold-dimensional-tolerances/toeboard-trigger-height/
10 feet
3.1 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
The top guy, tie or brace of completed scaffolds
[ "paragraph", "requirement_id", "requirement_type" ]
top-tie-maximum-distance-from-top
1926.451(c)(1)(ii)
Criteria for supported scaffolds
top-tie-maximum-distance-from-top
maximum distance
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top.
https://referencesource.org/osha-scaffold-dimensional-tolerances/top-tie-maximum-distance-from-top/
the 4:1 height
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
supported scaffolds manufactured or placed in service after January 1, 2000
[ "paragraph", "requirement_id", "requirement_type" ]
toprail-maximum-height-supported-after-2000
1926.451(g)(4)(ii)
Fall protection
toprail-maximum-height-supported-after-2000
maximum height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ii) The top edge height of toprails or equivalent member on supported scaffolds manufactured or placed in service after January 1, 2000 shall be installed between 38 inches (0.97 m) and 45 inches (1.2 m) above the platform surface.
https://referencesource.org/osha-scaffold-dimensional-tolerances/toprail-maximum-height-supported-after-2000/
45 inches
1.2 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
supported scaffolds manufactured and placed in service before January 1, 2000, and on all suspended scaffolds where both a guardrail and a personal fall arrest system are required
[ "paragraph", "requirement_id", "requirement_type" ]
toprail-maximum-height-supported-before-2000-and-suspended
1926.451(g)(4)(ii)
Fall protection
toprail-maximum-height-supported-before-2000-and-suspended
maximum height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
The top edge height on supported scaffolds manufactured and placed in service before January 1, 2000, and on all suspended scaffolds where both a guardrail and a personal fall arrest system are required shall be between 36 inches (0.9 m) and 45 inches (1.2 m).
https://referencesource.org/osha-scaffold-dimensional-tolerances/toprail-maximum-height-supported-before-2000-and-suspended/
45 inches
1.2 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
supported scaffolds manufactured or placed in service after January 1, 2000
[ "paragraph", "requirement_id", "requirement_type" ]
toprail-minimum-height-supported-after-2000
1926.451(g)(4)(ii)
Fall protection
toprail-minimum-height-supported-after-2000
minimum height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(ii) The top edge height of toprails or equivalent member on supported scaffolds manufactured or placed in service after January 1, 2000 shall be installed between 38 inches (0.97 m) and 45 inches (1.2 m) above the platform surface.
https://referencesource.org/osha-scaffold-dimensional-tolerances/toprail-minimum-height-supported-after-2000/
38 inches
0.97 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
supported scaffolds manufactured and placed in service before January 1, 2000, and on all suspended scaffolds where both a guardrail and a personal fall arrest system are required
[ "paragraph", "requirement_id", "requirement_type" ]
toprail-minimum-height-supported-before-2000-and-suspended
1926.451(g)(4)(ii)
Fall protection
toprail-minimum-height-supported-before-2000-and-suspended
minimum height
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
The top edge height on supported scaffolds manufactured and placed in service before January 1, 2000, and on all suspended scaffolds where both a guardrail and a personal fall arrest system are required shall be between 36 inches (0.9 m) and 45 inches (1.2 m).
https://referencesource.org/osha-scaffold-dimensional-tolerances/toprail-minimum-height-supported-before-2000-and-suspended/
36 inches
0.9 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
guardrail systems installed on all other scaffolds
[ "paragraph", "requirement_id", "requirement_type" ]
toprail-minimum-strength-all-other-scaffolds
1926.451(g)(4)(vii)
Fall protection
toprail-minimum-strength-all-other-scaffolds
minimum strength
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(vii) Each toprail or equivalent member of a guardrail system shall be capable of withstanding, without failure, a force applied in any downward or horizontal direction at any point along its top edge of at least 100 pounds (445 n) for guardrail systems installed on single-point adjustable suspension scaffolds or two-p...
https://referencesource.org/osha-scaffold-dimensional-tolerances/toprail-minimum-strength-all-other-scaffolds/
200 pounds
890 n
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
guardrail systems installed on single-point adjustable suspension scaffolds or two-point adjustable suspension scaffolds
[ "paragraph", "requirement_id", "requirement_type" ]
toprail-minimum-strength-suspension-scaffolds
1926.451(g)(4)(vii)
Fall protection
toprail-minimum-strength-suspension-scaffolds
minimum strength
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(vii) Each toprail or equivalent member of a guardrail system shall be capable of withstanding, without failure, a force applied in any downward or horizontal direction at any point along its top edge of at least 100 pounds (445 n) for guardrail systems installed on single-point adjustable suspension scaffolds or two-p...
https://referencesource.org/osha-scaffold-dimensional-tolerances/toprail-minimum-strength-suspension-scaffolds/
100 pounds
445 n
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
Each employee on a walkway located within a scaffold
[ "paragraph", "requirement_id", "requirement_type" ]
walkway-guardrail-maximum-distance
1926.451(g)(1)(v)
Fall protection
walkway-guardrail-maximum-distance
maximum distance
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(v) Each employee on a walkway located within a scaffold shall be protected by a guardrail system (with minimum 200 pound toprail capacity) installed within 91⁄2 inches (24.1 cm) of and along at least one side of the walkway.
https://referencesource.org/osha-scaffold-dimensional-tolerances/walkway-guardrail-maximum-distance/
91⁄2 inches
24.1 cm
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
the suspension wire rope when performing welding from suspended scaffolds
[ "paragraph", "requirement_id", "requirement_type" ]
welding-suspension-rope-insulation-minimum-extent
1926.451(f)(17)(ii)
Use
welding-suspension-rope-insulation-minimum-extent
minimum length
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(17) To reduce the possibility of welding current arcing through the suspension wire rope when performing welding from suspended scaffolds, the following precautions shall be taken, as applicable: (i) An insulated thimble shall be used to attach each suspension wire rope to its hanging support (such as cornice hook or ...
https://referencesource.org/osha-scaffold-dimensional-tolerances/welding-suspension-rope-insulation-minimum-extent/
4 feet
1.2 m
[ "applies_to", "regulation_section", "value_imperial", "value_metric" ]
null
winding drum hoists
[ "paragraph", "requirement_id", "requirement_type" ]
winding-drum-hoist-minimum-rope-wraps
1926.451(d)(6)
Criteria for suspension scaffolds
winding-drum-hoist-minimum-rope-wraps
minimum wraps
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(6) When winding drum hoists are used on a suspension scaffold, they shall contain not less than four wraps of the suspension rope at the lowest point of scaffold travel.
https://referencesource.org/osha-scaffold-dimensional-tolerances/winding-drum-hoist-minimum-rope-wraps/
four wraps of the suspension rope
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
wire rope clips are used on suspension scaffolds
[ "paragraph", "requirement_id", "requirement_type" ]
wire-rope-clip-minimum-spacing
1926.451(d)(12)(i)
Criteria for suspension scaffolds
wire-rope-clip-minimum-spacing
minimum spacing
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(12) When wire rope clips are used on suspension scaffolds: (i) There shall be a minimum of 3 wire rope clips installed, with the clips a minimum of 6 rope diameters apart;
https://referencesource.org/osha-scaffold-dimensional-tolerances/wire-rope-clip-minimum-spacing/
a minimum of 6 rope diameters apart
null
[ "applies_to", "regulation_section", "value_imperial" ]
null
wire rope clips are used on suspension scaffolds
[ "paragraph", "requirement_id", "requirement_type" ]
wire-rope-clips-minimum-number
1926.451(d)(12)(i)
Criteria for suspension scaffolds
wire-rope-clips-minimum-number
minimum count
https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451
(12) When wire rope clips are used on suspension scaffolds: (i) There shall be a minimum of 3 wire rope clips installed, with the clips a minimum of 6 rope diameters apart;
https://referencesource.org/osha-scaffold-dimensional-tolerances/wire-rope-clips-minimum-number/
a minimum of 3 wire rope clips
null
[ "applies_to", "regulation_section", "value_imperial" ]
null

Every numeric dimensional tolerance and safety factor in OSHA's scaffold general requirements (29 CFR 1926.451)

Canonical, always-current version: https://referencesource.org/osha-scaffold-dimensional-tolerances/ Machine-readable: https://referencesource.org/osha-scaffold-dimensional-tolerances/data.json — this mirror is a point-in-time copy.

  • Last verified: 2026-10-03
  • Stale after: 2027-08-31 (past this date, prefer the canonical copy — it re-verifies on a cadence this snapshot does not)
  • Records: 91

All of the specific numeric dimensional tolerances, clearances, safety factors, and spacing requirements stated in 29 CFR 1926.451 (General requirements for scaffolds), extracted from the eCFR text and tabulated so a scaffold erector or safety inspector can look up any measurement without reading the full 60,000-character regulation. Each record is one specific tolerance or requirement with its exact value in both imperial and metric units, the paragraph citation, and the condition or scaffold type it applies to. Answers 'what is the maximum gap between scaffold planks', 'how far can a scaffold plank overhang its support', 'what is the minimum platform width for a scaffold', 'at what height-to-base ratio must a scaffold be tied', 'what is the load safety factor for scaffold suspension ropes', 'what is the maximum distance from scaffold platform to work face for plastering'. Scaffolding is among OSHA's top 10 most cited standards every year (6th in FY 2025) and the numeric values are scattered across paragraphs (a) through (h) of a long regulation -- a tabulation that puts them all in one place with their paragraph citations is genuinely useful and does not exist as a structured page anywhere found.

Provenance — what every record carries

Every record carries source (the URL the value was read from) and source_quote (a verbatim quote from that page stating it). A value you cannot check against its page is indistinguishable from an invented one; these can all be checked. Each record is also individually addressable on the canonical site at its url.

Licence position

US federal regulation -- 17 USC 105, no copyright.

Facts are not copyrightable; what this dataset takes from each source is a fact plus a short attributed quote linking back to the page that states it.

Sources

Fields

See any record in data/records.jsonl — field names are self-describing, and the canonical page for each record renders them with labels: https://referencesource.org/osha-scaffold-dimensional-tolerances/

Downloads last month
63