Card: predictions are an AI model's output; add intended use
Browse files
README.md
CHANGED
|
@@ -80,6 +80,16 @@ differ (other scanners, thick slices, different labelling rules, repeat patients
|
|
| 80 |
eligibility rule, 6 have no measurable infrarenal diameter, 1 is a thorax CT). Scans the
|
| 81 |
baseline model fails on (for example Dice 0) are kept: a real cohort contains them.
|
| 82 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 83 |
## How the values were made
|
| 84 |
|
| 85 |
- **Ground-truth masks:** the segmentations distributed with TotalSegmentator v2.0.1,
|
|
@@ -89,9 +99,11 @@ baseline model fails on (for example Dice 0) are kept: a real cohort contains th
|
|
| 89 |
measured perpendicular to the centerline of the ground-truth aorta mask. `aaa` is
|
| 90 |
diameter >= 30 mm; `aaa_size_class` is `none`, `30-54mm` or `>=55mm`. These are
|
| 91 |
measurement-derived labels, not radiologist reads.
|
| 92 |
-
- **Predictions (baseline model):**
|
| 93 |
-
`total` task) on each CT and applied
|
| 94 |
-
|
|
|
|
|
|
|
| 95 |
`_pred` columns the model's.
|
| 96 |
- **The baseline model has seen most of these scans.** TotalSegmentator was trained on
|
| 97 |
this dataset: of the 567 scans, its own split (`totalsegmentator_split` in
|
|
|
|
| 80 |
eligibility rule, 6 have no measurable infrarenal diameter, 1 is a thorax CT). Scans the
|
| 81 |
baseline model fails on (for example Dice 0) are kept: a real cohort contains them.
|
| 82 |
|
| 83 |
+
## Intended use
|
| 84 |
+
|
| 85 |
+
A test harness for checking how an imaging AI model behaves at a new site, not a
|
| 86 |
+
leaderboard. The ground-truth masks are independent of any one model, so you can train
|
| 87 |
+
your own classifiers or segmenters (AAA, enlarged kidneys, organ volumes) on one part of the
|
| 88 |
+
data, apply them to another, and see how shifts in scanners, slice thickness, phase, age or
|
| 89 |
+
case mix, or hidden subgroups, change their results. The aim is to show the difference
|
| 90 |
+
between a model's results on clean development data and on a site's own data, not to
|
| 91 |
+
build the best model.
|
| 92 |
+
|
| 93 |
## How the values were made
|
| 94 |
|
| 95 |
- **Ground-truth masks:** the segmentations distributed with TotalSegmentator v2.0.1,
|
|
|
|
| 99 |
measured perpendicular to the centerline of the ground-truth aorta mask. `aaa` is
|
| 100 |
diameter >= 30 mm; `aaa_size_class` is `none`, `30-54mm` or `>=55mm`. These are
|
| 101 |
measurement-derived labels, not radiologist reads.
|
| 102 |
+
- **Predictions (baseline model):** the output of an AI model, not a second ground truth.
|
| 103 |
+
We ran the public TotalSegmentator model (v2.18.0, `total` task) on each CT and applied
|
| 104 |
+
the same measurement and 30 mm rule to its aorta mask. It stands in for the kind of
|
| 105 |
+
nnU-Net-based segmentation found in commercial imaging AI products. Null means the
|
| 106 |
+
model gave no answer. `_ref` columns use the ground-truth masks,
|
| 107 |
`_pred` columns the model's.
|
| 108 |
- **The baseline model has seen most of these scans.** TotalSegmentator was trained on
|
| 109 |
this dataset: of the 567 scans, its own split (`totalsegmentator_split` in
|