Dataset Viewer
Auto-converted to Parquet Duplicate
record_type
stringclasses
1 value
plant_name
stringlengths
4
22
owner_entity
stringlengths
16
39
state
stringlengths
2
2
balancing_authority
stringclasses
10 values
technology
stringclasses
3 values
nameplate_mw
float64
84.5
1.3k
planned_retirement_year
float64
2.03k
2.03k
plant_nameplate_mw
float64
892
3.29k
plant_retiring_mw
float64
892
2.6k
plant_retiring_share
float64
0.37
1
latitude
float64
29.3
45.4
longitude
float64
-119.17
-76.54
planned retirement
Rockport
Indiana Michigan Power Co
IN
PJM
Conventional Steam Coal
1,300
2,028
2,600
2,600
1
37.9256
-87.0372
planned retirement
Gallatin (TN)
Tennessee Valley Authority
TN
TVA
Natural Gas Fired Combustion Turbine
84.5
2,031
1,918.4
1,918.4
1
36.3156
-86.4006
planned retirement
Sherburne County
Northern States Power Co - Minnesota
MN
MISO
Conventional Steam Coal
938.7
2,030
1,704
1,704
1
45.3808
-93.8931
planned retirement
Monroe (MI)
DTE Electric Company
MI
MISO
Conventional Steam Coal
817.2
2,028
3,293.1
1,639.8
0.498
41.8906
-83.3464
planned retirement
Four Corners
Arizona Public Service Co
NM
AZPS
Conventional Steam Coal
818.1
2,031
1,636.2
1,636.2
1
36.69
-108.4814
planned retirement
Ormond Beach
Ormond Beach Power, LLC
CA
CISO
Natural Gas Steam Turbine
806
2,027
1,612
1,612
1
34.1292
-119.1689
planned retirement
J H Campbell
Consumers Energy Co - (MI)
MI
MISO
Conventional Steam Coal
265.2
2,026
1,560.8
1,560.8
1
42.910296
-86.20074
planned retirement
Craig (CO)
Tri-State G & T Assn, Inc
CO
WACM
Conventional Steam Coal
534.8
2,029
1,427.6
1,427.6
1
40.4627
-107.5912
planned retirement
Belle River
DTE Electric Company
MI
MISO
Conventional Steam Coal
697.5
2,028
1,664.4
1,395
0.838
42.7756
-82.495
planned retirement
Brandon Shores
Brandon Shores LLC
MD
PJM
Conventional Steam Coal
685.1
2,029
1,370.2
1,370.2
1
39.182073
-76.53715
planned retirement
Kincaid Generation LLC
Dynegy Kincaid Generation
IL
PJM
Conventional Steam Coal
659.5
2,027
1,319
1,319
1
39.590556
-89.49639
planned retirement
Sabine
Entergy Texas Inc.
TX
MISO
Natural Gas Steam Turbine
473.4
2,026
1,811.8
1,304.4
0.72
30.0242
-93.878
planned retirement
Cumberland (TN)
Tennessee Valley Authority
TN
TVA
Conventional Steam Coal
1,300
2,028
2,600
1,300
0.5
36.3903
-87.6539
planned retirement
Winyah
South Carolina Public Service Authority
SC
SC
Conventional Steam Coal
315
2,030
1,275.8
1,275.8
1
33.33184
-79.35724
planned retirement
Baldwin Energy Complex
Dynegy Midwest Generation Inc
IL
MISO
Conventional Steam Coal
625.1
2,027
1,259.6
1,259.6
1
38.205
-89.8544
planned retirement
Comanche (CO)
Public Service Co of Colorado
CO
WACM
Conventional Steam Coal
396
2,026
1,252.8
1,252.8
1
38.2081
-104.5747
planned retirement
Tolk
Southwestern Public Service Co
TX
SWPP
Conventional Steam Coal
567.9
2,028
1,135.8
1,135.8
1
34.186494
-102.57
planned retirement
AES Alamitos LLC
AES Alamitos LLC
CA
CISO
Natural Gas Steam Turbine
310
2,026
1,115
1,115
1
33.7688
-118.1009
planned retirement
Columbia (WI)
Wisconsin Power & Light Co
WI
MISO
Conventional Steam Coal
556
2,029
1,112
1,112
1
43.4864
-89.4203
planned retirement
Kingston
Tennessee Valley Authority
TN
TVA
Conventional Steam Coal
200
2,027
1,700
1,100
0.647
35.8992
-84.5194
planned retirement
Sioux
Union Electric Co - (MO)
MO
MISO
Conventional Steam Coal
549.7
2,028
1,099.4
1,099.4
1
38.915479
-90.29025
planned retirement
Victor J Daniel Jr
Mississippi Power Co
MS
SOCO
Conventional Steam Coal
548.3
2,027
2,229
1,096.6
0.492
30.5322
-88.5553
planned retirement
Little Gypsy
Entergy Louisiana LLC
LA
MISO
Natural Gas Steam Turbine
420.7
2,029
1,002.9
1,002.9
1
30.005067
-90.46169
planned retirement
Nine Mile Point
Entergy Louisiana LLC
LA
MISO
Natural Gas Steam Turbine
895.1
2,031
2,439.7
895.1
0.367
29.9472
-90.1458
planned retirement
O W Sommers
City of San Antonio - (TX)
TX
ERCO
Natural Gas Steam Turbine
446
2,027
892
892
1
29.308056
-98.3242

Retiring Power Plant Sites: free sample (Tensorust LLC)

Every U.S. generator scheduled to retire through 2031, and every one that retired since 2022, with the site, owner and grid.

Headline: 53,153 MW of operating U.S. generating capacity, 285 generators at 132 plants, carries a planned retirement date between 2026 and 2031 in EIA's September 2026 860M, and another 54,411 MW retired from 2022 on.

This repository is a free teaser, not the dataset. It holds 25 example rows and a summary table with no names in it. The full file has 1,648 rows and is sold by Tensorust LLC: https://tensorust.com/datasets/eia860-retirements/.

Files here

file what it is
sample.csv 25 rows of the full file (the same sample shown on tensorust.com)
summary_by_state.csv row counts and totals by state across the full file, no entity names (groups with fewer than 3 rows are folded into "Other")

Summary by state (largest groups)

State rows Nameplate capacity (MW)
CA 255 5,750
VA 138 2,518
NY 81 1,367
OH 75 4,651
TX 71 8,336
IL 67 10,389
NJ 67 1,511
NC 62 1,992
MN 60 4,593
TN 59 6,951
AK 51 54
CO 45 5,101
TOTAL 1,648 107,561

Full table: summary_by_state.csv.

What the full file has

  • 1,648 rows
  • Key fields: record_type, plant_id, plant_name, generator_id, owner_entity_id, owner_entity, state, county, latitude, longitude
  • Parquet and CSV, a README with sources, method and limits, and the build script
  • Free 25-row sample (no personal contact data)

Coverage: All U.S. generators of 1 MW or more reported on EIA-860M: 1,648 generator rows at 662 plants, 107,564 MW. EIA-860M September 2026 release; built Nov 6 2026

Columns in the full file

column meaning
record_type planned retirement (still operating) or retired since 2022
plant_id EIA plant code
plant_name Plant name
generator_id EIA generator id
owner_entity_id EIA entity id of the reporting owner or operator
owner_entity Reporting entity name
state Plant state
county Plant county
latitude Plant latitude
longitude Plant longitude
balancing_authority Balancing authority code (PJM, MISO, CISO and so on)
sector EIA sector (utility, IPP, CHP and so on)
technology EIA technology
fuel_code Energy source code
prime_mover Prime mover code
nameplate_mw Generator nameplate MW
summer_mw Net summer capacity MW
operating_year Year the generator went into service
planned_retirement_year Planned (or actual, for retired rows) retirement year
planned_retirement_month Planned or actual retirement month
years_in_service_at_retirement Retirement year minus operating year
status EIA status code, or retired
plant_nameplate_mw Plant's total operating nameplate MW now (0 when the plant is fully retired)
plant_generators Operating generators at the plant
plant_retiring_mw Plant MW with a planned retirement 2026 to 2031
plant_retiring_share plant_retiring_mw over plant_nameplate_mw
plant_retired_since_2022_mw Plant MW retired 2022 on
plant_fully_closed True when the plant has no operating capacity left
owner_oid Tensorust ontology organization id for the owner
owner_sources Public sources the owner appears in
owner_federal_awards_fy25plus Owner's federal awards FY2025 on, USD (ontology)

Get the full file

tier price includes
Grid region file $750 Every planned and recent retirement in one balancing authority or up to 3 states, with coordinates, plant shares and owners. CSV, Excel and a map-ready GeoJSON on request.
National site list $3,500 All 1,648 generators at 662 plants nationwide, plant roll-ups, owner ontology links.
Monthly tracker $9,000 a year The national list re-run on every monthly EIA-860M release, with retirement dates that moved, new announcements and plants that fully closed marked. Internal use, unlimited seats.

Email mattbusel@tensorust.com with the tier and a billing contact, and we will send a proper invoice (ACH or card). The file is delivered once the invoice is paid. Details and the live sample: https://tensorust.com/datasets/eia860-retirements/. All datasets: https://tensorust.com/datasets/

Method and limits

Read the EIA-860M September 2026 generator workbook, keep Operating generators with a planned retirement year 2026 to 2031 and Retired generators with a retirement year of 2022 or later, sum each plant's operating nameplate, compute the plant's retiring MW and share, flag plants with no operating capacity left, and join the owner name to the Tensorust ontology (111 of 455 owners matched).

Not a list of sites for sale, not a firm retirement (owners move planned dates, and EIA reports what owners file), and not interconnection rights (reusing a point of interconnection depends on the grid operator's rules). Owner is the EIA reporting entity, not every co-owner.

Sources

License

The sample and summary here are free to view, analyze and cite with attribution to "Tensorust LLC, https://tensorust.com/datasets/eia860-retirements/". The full dataset is licensed separately per tier. No resale or redistribution of Tensorust data without a written license.

Tensorust LLC, Tuckahoe NY. mattbusel@tensorust.com | https://tensorust.com

Downloads last month
45