Datasets:
UMI Plus Manipulation Tasks
LeRobot v2.1 dataset containing 483 demonstrations, 66,838 frames, and eight tasks at 20 Hz. All task instructions are in English. The test-tube task uses a test tube brush, which is inserted into a test tube in the orange rack on the right.
| Task index | Instruction | Episodes |
|---|---|---|
| 0 | Pick up the power adapter and insert its plug into a socket on the power strip. | 67 |
| 1 | Pick up the USB connector and insert it into a USB port on the power strip. | 56 |
| 2 | Pick up the black perforated plate, align its holes with the two pegs, and fit the plate onto the pegs. | 58 |
| 3 | Fold the brown towel in half by bringing one short edge over to the opposite short edge. | 59 |
| 4 | Fold the brown towel diagonally by bringing one corner over to the opposite corner to form a triangle. | 60 |
| 5 | Pick up the light-colored lid, align it with the gray box, and press it into place to close the box. | 57 |
| 6 | Grasp the cap of the blue bottle, twist it, and remove it from the bottle. | 59 |
| 7 | Pick up the test tube brush and insert it into the test tube in the orange rack on the right. | 67 |
Data representation
image,wrist_image, andtactile_image: embedded 224 x 224 RGB PNG images.state: seven float32 values (position, rotation vector, and gripper opening).actions: thirteen float32 values (next-step state and bilateral XYZ force).tactile_gripper_force: eight samples of bilateral XYZ force, shape (8, 6).tactile_marker_motion: initial bilateral markers followed by eight history samples, shape (9, 440, 2).
The final action repeats the last target. History windows are padded with the first sample.
The current left and right tactile images are placed side by side (current_lr).
Images are embedded in Parquet; external video files are not required.
Conversion
This dataset uses the same UMI conversion implementation as realworld_taskumi,
with the sampling rate set to 20 Hz. It retains UMI relative-pose reconstruction, unit normalization,
the existing tactile-force filter, and the standard Tabero EEF mapping.
The SDK reference pose is [251.542175, -5.547043, 207.964020, 82.510735, -88.606949, 97.333672]
in millimetres and XYZ Euler degrees. Gripper calibration maps -2.828831921873807 radians
to fully open (1) and 0.1195925841153578 radians to closed (0).
Position features use metres and rotation vectors use radians.
The pose is reconstructed from hand-held UMI recordings; it is not an independently
measured robot joint/EEF state. The original recordings remain unchanged.
Ten recordings with major trajectory interruptions, missing starts, or a large position
jump were excluded before conversion. The remaining recordings are cut per episode to remove the task-end return to the start pose.
All modalities are clipped by the same third-camera cutoff timestamp before rebuilding a fixed 20 Hz clock.
Release-based boundaries retain towel settling; cap-removal boundaries are reviewed separately.
Cutoff provenance is in meta/episode_sources.jsonl. Numeric inference and sampled visual review
were used for seven tasks, with every cap-removal boundary visually reviewed. Marker sampling gaps present
in the recordings are retained and handled by the original timestamp-alignment method.
Successful parsing and conversion do not constitute a per-episode task-success label.
- Downloads last month
- 446