Dataset Viewer
Auto-converted to Parquet Duplicate
id
stringlengths
14
14
split
stringclasses
1 value
regime
stringclasses
3 values
prompt
stringclasses
1 value
public_plant_spec
stringlengths
438
443
nominal_dispatch_curve
listlengths
24
24
initial_board
stringlengths
389
394
reference_dispatch_mwh
float64
4.05k
6.14k
specimen
stringlengths
35
35
xenon-train-00
train
pump_derate
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 3.076e-05, "doppler_pcm_per_k": -2.4064, "moderator_pcm_per_k": -22.4993, "boron_worth_pcm_per_ppm": -7.2295, "rod_bank_worth_pcm": 6591.8, "flux_at_rated_n_cm2_s": 29679383870629.484, "peaking_factor_fq": 2.1629, "initial_boron_ppm": 366.636, "initial_pump_flow_frac": 1.0, "history_equilib...
[ 0.935, 0.935, 0.935, 0.935, 0.7894, 0.623, 0.519, 0.519, 0.519, 0.519, 0.519, 0.519, 0.519, 0.519, 0.519, 0.6565, 0.8138, 0.912, 0.912, 0.912, 0.912, 0.912, 0.912, 0.912 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.934995, "measured_tavg_k": 581.0353, "measured_dnbr": 1.6717, "rod_position_frac": 0.550929, "boron_ppm": 384.592, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.97293, "tripped": false, "next_target_power_frac": 0.935, "live_pump_flow_ca...
4,269.8789
specimens/train/xenon-train-00.json
xenon-train-01
train
demand_surge
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.97e-05, "doppler_pcm_per_k": -3.0532, "moderator_pcm_per_k": -26.1744, "boron_worth_pcm_per_ppm": -7.3244, "rod_bank_worth_pcm": 6643.32, "flux_at_rated_n_cm2_s": 30145470699870.34, "peaking_factor_fq": 2.1587, "initial_boron_ppm": 259.33, "initial_pump_flow_frac": 1.0, "history_equilibri...
[ 0.936, 0.936, 0.936, 0.936, 0.782, 0.606, 0.496, 0.496, 0.496, 0.496, 0.496, 0.496, 0.496, 0.496, 0.496, 0.6395, 0.8035, 0.906, 0.906, 0.906, 0.906, 0.906, 0.906, 0.906 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.936003, "measured_tavg_k": 579.0494, "measured_dnbr": 1.8504, "rod_position_frac": 0.765125, "boron_ppm": 227.605, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.97332, "tripped": false, "next_target_power_frac": 0.936, "live_pump_flow_ca...
5,616.2063
specimens/train/xenon-train-01.json
xenon-train-02
train
deep_curtailment
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.942e-05, "doppler_pcm_per_k": -2.1968, "moderator_pcm_per_k": -30.788, "boron_worth_pcm_per_ppm": -8.8885, "rod_bank_worth_pcm": 7310.16, "flux_at_rated_n_cm2_s": 30767770102525.93, "peaking_factor_fq": 2.2318, "initial_boron_ppm": 289.65, "initial_pump_flow_frac": 1.0, "history_equilibri...
[ 0.886, 0.886, 0.886, 0.886, 0.7835, 0.6663, 0.593, 0.593, 0.593, 0.593, 0.593, 0.593, 0.593, 0.593, 0.593, 0.7036, 0.83, 0.909, 0.909, 0.909, 0.909, 0.909, 0.909, 0.909 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.885998, "measured_tavg_k": 581.597, "measured_dnbr": 1.9339, "rod_position_frac": 0.75988, "boron_ppm": 267.959, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.91199, "tripped": false, "next_target_power_frac": 0.886, "live_pump_flow_cap"...
4,156.1955
specimens/train/xenon-train-02.json
xenon-train-03
train
pump_derate
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.264e-05, "doppler_pcm_per_k": -2.6617, "moderator_pcm_per_k": -24.2143, "boron_worth_pcm_per_ppm": -8.7886, "rod_bank_worth_pcm": 7252.74, "flux_at_rated_n_cm2_s": 30062534590964.047, "peaking_factor_fq": 2.2503, "initial_boron_ppm": 296.737, "initial_pump_flow_frac": 1.0, "history_equili...
[ 0.899, 0.899, 0.899, 0.899, 0.7881, 0.6613, 0.582, 0.582, 0.582, 0.582, 0.582, 0.582, 0.582, 0.582, 0.582, 0.6796, 0.7913, 0.861, 0.861, 0.861, 0.861, 0.861, 0.861, 0.861 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.899001, "measured_tavg_k": 578.5131, "measured_dnbr": 1.7744, "rod_position_frac": 0.823843, "boron_ppm": 331.284, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.87029, "tripped": false, "next_target_power_frac": 0.899, "live_pump_flow_ca...
4,513.9328
specimens/train/xenon-train-03.json
xenon-train-04
train
demand_surge
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 3.02e-05, "doppler_pcm_per_k": -2.1183, "moderator_pcm_per_k": -26.0164, "boron_worth_pcm_per_ppm": -7.4741, "rod_bank_worth_pcm": 7290.41, "flux_at_rated_n_cm2_s": 31709939759040.2, "peaking_factor_fq": 2.3181, "initial_boron_ppm": 307.56, "initial_pump_flow_frac": 1.0, "history_equilibriu...
[ 0.89, 0.89, 0.89, 0.89, 0.7658, 0.6238, 0.535, 0.535, 0.535, 0.535, 0.535, 0.535, 0.535, 0.535, 0.535, 0.6502, 0.7818, 0.864, 0.864, 0.864, 0.864, 0.864, 0.864, 0.864 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.889999, "measured_tavg_k": 580.8695, "measured_dnbr": 2.1607, "rod_position_frac": 0.563621, "boron_ppm": 413.594, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.85613, "tripped": false, "next_target_power_frac": 0.89, "live_pump_flow_cap...
6,067.4442
specimens/train/xenon-train-04.json
xenon-train-05
train
deep_curtailment
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.991e-05, "doppler_pcm_per_k": -2.5787, "moderator_pcm_per_k": -24.4883, "boron_worth_pcm_per_ppm": -8.3662, "rod_bank_worth_pcm": 6505.07, "flux_at_rated_n_cm2_s": 31307365753922.484, "peaking_factor_fq": 2.3662, "initial_boron_ppm": 330.1, "initial_pump_flow_frac": 1.0, "history_equilibr...
[ 0.921, 0.921, 0.921, 0.921, 0.7775, 0.6135, 0.511, 0.511, 0.511, 0.511, 0.511, 0.511, 0.511, 0.511, 0.511, 0.636, 0.7788, 0.868, 0.868, 0.868, 0.868, 0.868, 0.868, 0.868 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.920998, "measured_tavg_k": 578.6276, "measured_dnbr": 1.9546, "rod_position_frac": 0.625393, "boron_ppm": 334.021, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.89579, "tripped": false, "next_target_power_frac": 0.921, "live_pump_flow_ca...
4,537.9207
specimens/train/xenon-train-05.json
xenon-train-06
train
pump_derate
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 3.164e-05, "doppler_pcm_per_k": -2.8669, "moderator_pcm_per_k": -28.5247, "boron_worth_pcm_per_ppm": -8.0343, "rod_bank_worth_pcm": 7034.07, "flux_at_rated_n_cm2_s": 28452334805105.598, "peaking_factor_fq": 2.2961, "initial_boron_ppm": 230.445, "initial_pump_flow_frac": 1.0, "history_equili...
[ 0.877, 0.877, 0.877, 0.877, 0.771, 0.6498, 0.574, 0.574, 0.574, 0.574, 0.574, 0.574, 0.574, 0.574, 0.574, 0.6954, 0.8342, 0.921, 0.921, 0.921, 0.921, 0.921, 0.921, 0.921 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.876995, "measured_tavg_k": 581.0363, "measured_dnbr": 1.823, "rod_position_frac": 0.654009, "boron_ppm": 327.142, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.90609, "tripped": false, "next_target_power_frac": 0.877, "live_pump_flow_cap...
4,735.0566
specimens/train/xenon-train-06.json
xenon-train-07
train
demand_surge
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.589e-05, "doppler_pcm_per_k": -2.8321, "moderator_pcm_per_k": -34.9278, "boron_worth_pcm_per_ppm": -7.9538, "rod_bank_worth_pcm": 7153.98, "flux_at_rated_n_cm2_s": 28192075116931.22, "peaking_factor_fq": 2.3267, "initial_boron_ppm": 294.881, "initial_pump_flow_frac": 1.0, "history_equilib...
[ 0.867, 0.867, 0.867, 0.867, 0.741, 0.597, 0.507, 0.507, 0.507, 0.507, 0.507, 0.507, 0.507, 0.507, 0.507, 0.6347, 0.7808, 0.872, 0.872, 0.872, 0.872, 0.872, 0.872, 0.872 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.867002, "measured_tavg_k": 578.3411, "measured_dnbr": 2.041, "rod_position_frac": 0.661776, "boron_ppm": 247.586, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.90139, "tripped": false, "next_target_power_frac": 0.867, "live_pump_flow_cap...
4,679.2165
specimens/train/xenon-train-07.json
xenon-train-08
train
deep_curtailment
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.128e-05, "doppler_pcm_per_k": -2.5606, "moderator_pcm_per_k": -22.3298, "boron_worth_pcm_per_ppm": -8.8093, "rod_bank_worth_pcm": 6235.19, "flux_at_rated_n_cm2_s": 28067692795782.41, "peaking_factor_fq": 2.376, "initial_boron_ppm": 223.527, "initial_pump_flow_frac": 1.0, "history_equilibr...
[ 0.905, 0.905, 0.905, 0.905, 0.7822, 0.6418, 0.554, 0.554, 0.554, 0.554, 0.554, 0.554, 0.554, 0.554, 0.554, 0.6716, 0.806, 0.89, 0.89, 0.89, 0.89, 0.89, 0.89, 0.89 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.904996, "measured_tavg_k": 581.1773, "measured_dnbr": 2.0956, "rod_position_frac": 0.669137, "boron_ppm": 308.918, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.93715, "tripped": false, "next_target_power_frac": 0.905, "live_pump_flow_ca...
4,325.2275
specimens/train/xenon-train-08.json
xenon-train-09
train
pump_derate
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.323e-05, "doppler_pcm_per_k": -2.9962, "moderator_pcm_per_k": -25.9212, "boron_worth_pcm_per_ppm": -8.5014, "rod_bank_worth_pcm": 6305.2, "flux_at_rated_n_cm2_s": 31412385697333.113, "peaking_factor_fq": 2.2735, "initial_boron_ppm": 222.455, "initial_pump_flow_frac": 1.0, "history_equilib...
[ 0.926, 0.926, 0.926, 0.926, 0.8084, 0.674, 0.59, 0.59, 0.59, 0.59, 0.59, 0.59, 0.59, 0.59, 0.59, 0.7143, 0.8562, 0.945, 0.945, 0.945, 0.945, 0.945, 0.945, 0.945 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.925998, "measured_tavg_k": 578.7098, "measured_dnbr": 1.7236, "rod_position_frac": 0.675753, "boron_ppm": 221.14, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.90175, "tripped": false, "next_target_power_frac": 0.926, "live_pump_flow_cap...
4,488.7889
specimens/train/xenon-train-09.json
xenon-train-10
train
demand_surge
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 1.99e-05, "doppler_pcm_per_k": -2.1731, "moderator_pcm_per_k": -29.7374, "boron_worth_pcm_per_ppm": -8.8217, "rod_bank_worth_pcm": 6451.67, "flux_at_rated_n_cm2_s": 29671669372744.67, "peaking_factor_fq": 2.2383, "initial_boron_ppm": 291.911, "initial_pump_flow_frac": 1.0, "history_equilibr...
[ 0.895, 0.895, 0.895, 0.895, 0.7802, 0.649, 0.567, 0.567, 0.567, 0.567, 0.567, 0.567, 0.567, 0.567, 0.567, 0.6727, 0.7935, 0.869, 0.869, 0.869, 0.869, 0.869, 0.869, 0.869 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.894998, "measured_tavg_k": 581.3843, "measured_dnbr": 1.9691, "rod_position_frac": 0.62181, "boron_ppm": 299.307, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.86012, "tripped": false, "next_target_power_frac": 0.895, "live_pump_flow_cap...
5,193.2294
specimens/train/xenon-train-10.json
xenon-train-11
train
deep_curtailment
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.925e-05, "doppler_pcm_per_k": -2.6538, "moderator_pcm_per_k": -25.5532, "boron_worth_pcm_per_ppm": -7.4734, "rod_bank_worth_pcm": 6552.48, "flux_at_rated_n_cm2_s": 28750441436186.016, "peaking_factor_fq": 2.1688, "initial_boron_ppm": 236.994, "initial_pump_flow_frac": 1.0, "history_equili...
[ 0.883, 0.883, 0.883, 0.883, 0.7801, 0.6625, 0.589, 0.589, 0.589, 0.589, 0.589, 0.589, 0.589, 0.589, 0.589, 0.7087, 0.8455, 0.931, 0.931, 0.931, 0.931, 0.931, 0.931, 0.931 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.882996, "measured_tavg_k": 578.4381, "measured_dnbr": 1.964, "rod_position_frac": 0.716457, "boron_ppm": 188.369, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.85279, "tripped": false, "next_target_power_frac": 0.883, "live_pump_flow_cap...
4,250.1834
specimens/train/xenon-train-11.json
xenon-train-12
train
pump_derate
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 1.962e-05, "doppler_pcm_per_k": -2.2404, "moderator_pcm_per_k": -32.5296, "boron_worth_pcm_per_ppm": -7.7703, "rod_bank_worth_pcm": 6620.64, "flux_at_rated_n_cm2_s": 29025258209004.88, "peaking_factor_fq": 2.3504, "initial_boron_ppm": 354.098, "initial_pump_flow_frac": 1.0, "history_equilib...
[ 0.84, 0.84, 0.84, 0.84, 0.7305, 0.6052, 0.527, 0.527, 0.527, 0.527, 0.527, 0.527, 0.527, 0.527, 0.527, 0.6484, 0.7873, 0.874, 0.874, 0.874, 0.874, 0.874, 0.874, 0.874 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.84, "measured_tavg_k": 581.4272, "measured_dnbr": 1.8612, "rod_position_frac": 0.579381, "boron_ppm": 368.891, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.87583, "tripped": false, "next_target_power_frac": 0.84, "live_pump_flow_cap": 1...
4,514.2057
specimens/train/xenon-train-12.json
xenon-train-13
train
demand_surge
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.752e-05, "doppler_pcm_per_k": -2.8575, "moderator_pcm_per_k": -30.3374, "boron_worth_pcm_per_ppm": -8.6484, "rod_bank_worth_pcm": 6913.47, "flux_at_rated_n_cm2_s": 30983096004948.285, "peaking_factor_fq": 2.3593, "initial_boron_ppm": 348.771, "initial_pump_flow_frac": 1.0, "history_equili...
[ 0.934, 0.934, 0.934, 0.934, 0.78, 0.604, 0.494, 0.494, 0.494, 0.494, 0.494, 0.494, 0.494, 0.494, 0.494, 0.6452, 0.818, 0.926, 0.926, 0.926, 0.926, 0.926, 0.926, 0.926 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.934002, "measured_tavg_k": 578.841, "measured_dnbr": 1.992, "rod_position_frac": 0.565488, "boron_ppm": 354.535, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.96449, "tripped": false, "next_target_power_frac": 0.934, "live_pump_flow_cap"...
5,549.4757
specimens/train/xenon-train-13.json
xenon-train-14
train
deep_curtailment
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.794e-05, "doppler_pcm_per_k": -3.0217, "moderator_pcm_per_k": -33.3946, "boron_worth_pcm_per_ppm": -7.409, "rod_bank_worth_pcm": 6705.98, "flux_at_rated_n_cm2_s": 28938149623894.414, "peaking_factor_fq": 2.3178, "initial_boron_ppm": 228.328, "initial_pump_flow_frac": 1.0, "history_equilib...
[ 0.904, 0.904, 0.904, 0.904, 0.7601, 0.5958, 0.493, 0.493, 0.493, 0.493, 0.493, 0.493, 0.493, 0.493, 0.493, 0.6361, 0.7997, 0.902, 0.902, 0.902, 0.902, 0.902, 0.902, 0.902 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.904, "measured_tavg_k": 581.5977, "measured_dnbr": 1.8767, "rod_position_frac": 0.667441, "boron_ppm": 290.8, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.92898, "tripped": false, "next_target_power_frac": 0.904, "live_pump_flow_cap": 1...
4,073.8029
specimens/train/xenon-train-14.json
xenon-train-15
train
pump_derate
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 3.142e-05, "doppler_pcm_per_k": -2.7329, "moderator_pcm_per_k": -30.2402, "boron_worth_pcm_per_ppm": -8.2045, "rod_bank_worth_pcm": 7301.33, "flux_at_rated_n_cm2_s": 29911037345716.434, "peaking_factor_fq": 2.2815, "initial_boron_ppm": 250.312, "initial_pump_flow_frac": 1.0, "history_equili...
[ 0.91, 0.91, 0.91, 0.91, 0.7654, 0.6003, 0.497, 0.497, 0.497, 0.497, 0.497, 0.497, 0.497, 0.497, 0.497, 0.643, 0.8097, 0.914, 0.914, 0.914, 0.914, 0.914, 0.914, 0.914 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.909997, "measured_tavg_k": 578.546, "measured_dnbr": 1.7632, "rod_position_frac": 0.659104, "boron_ppm": 318.456, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.88679, "tripped": false, "next_target_power_frac": 0.91, "live_pump_flow_cap"...
4,319.9685
specimens/train/xenon-train-15.json
xenon-train-16
train
demand_surge
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.499e-05, "doppler_pcm_per_k": -2.6782, "moderator_pcm_per_k": -22.4743, "boron_worth_pcm_per_ppm": -8.831, "rod_bank_worth_pcm": 6672.99, "flux_at_rated_n_cm2_s": 30072475907854.195, "peaking_factor_fq": 2.1771, "initial_boron_ppm": 283.146, "initial_pump_flow_frac": 1.0, "history_equilib...
[ 0.938, 0.938, 0.938, 0.938, 0.8054, 0.6538, 0.559, 0.559, 0.559, 0.559, 0.559, 0.559, 0.559, 0.559, 0.559, 0.6703, 0.7975, 0.877, 0.877, 0.877, 0.877, 0.877, 0.877, 0.877 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.938003, "measured_tavg_k": 581.3544, "measured_dnbr": 1.8989, "rod_position_frac": 0.573054, "boron_ppm": 347.038, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.91575, "tripped": false, "next_target_power_frac": 0.938, "live_pump_flow_ca...
5,474.1535
specimens/train/xenon-train-16.json
xenon-train-17
train
deep_curtailment
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 1.989e-05, "doppler_pcm_per_k": -3.0947, "moderator_pcm_per_k": -34.0666, "boron_worth_pcm_per_ppm": -8.0811, "rod_bank_worth_pcm": 7001.64, "flux_at_rated_n_cm2_s": 31113007498229.46, "peaking_factor_fq": 2.1751, "initial_boron_ppm": 353.719, "initial_pump_flow_frac": 1.0, "history_equilib...
[ 0.863, 0.863, 0.863, 0.863, 0.7433, 0.6065, 0.521, 0.521, 0.521, 0.521, 0.521, 0.521, 0.521, 0.521, 0.521, 0.6418, 0.7797, 0.866, 0.866, 0.866, 0.866, 0.866, 0.866, 0.866 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.863003, "measured_tavg_k": 578.4429, "measured_dnbr": 2.2933, "rod_position_frac": 0.606414, "boron_ppm": 428.664, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.83803, "tripped": false, "next_target_power_frac": 0.863, "live_pump_flow_ca...
4,113.232
specimens/train/xenon-train-17.json
xenon-train-18
train
pump_derate
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.51e-05, "doppler_pcm_per_k": -2.3452, "moderator_pcm_per_k": -31.423, "boron_worth_pcm_per_ppm": -8.0681, "rod_bank_worth_pcm": 7150.45, "flux_at_rated_n_cm2_s": 30522702252944.094, "peaking_factor_fq": 2.3579, "initial_boron_ppm": 342.663, "initial_pump_flow_frac": 1.0, "history_equilibr...
[ 0.914, 0.914, 0.914, 0.914, 0.788, 0.644, 0.554, 0.554, 0.554, 0.554, 0.554, 0.554, 0.554, 0.554, 0.554, 0.6639, 0.7895, 0.868, 0.868, 0.868, 0.868, 0.868, 0.868, 0.868 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.914001, "measured_tavg_k": 581.1821, "measured_dnbr": 1.7614, "rod_position_frac": 0.730087, "boron_ppm": 435.92, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.95051, "tripped": false, "next_target_power_frac": 0.914, "live_pump_flow_cap...
4,264.7757
specimens/train/xenon-train-18.json
xenon-train-19
train
demand_surge
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 3.058e-05, "doppler_pcm_per_k": -2.5312, "moderator_pcm_per_k": -31.2462, "boron_worth_pcm_per_ppm": -8.2537, "rod_bank_worth_pcm": 7055.77, "flux_at_rated_n_cm2_s": 31465219109078.73, "peaking_factor_fq": 2.3514, "initial_boron_ppm": 357.136, "initial_pump_flow_frac": 1.0, "history_equilib...
[ 0.913, 0.913, 0.913, 0.913, 0.7835, 0.6355, 0.543, 0.543, 0.543, 0.543, 0.543, 0.543, 0.543, 0.543, 0.543, 0.6841, 0.8453, 0.946, 0.946, 0.946, 0.946, 0.946, 0.946, 0.946 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.912999, "measured_tavg_k": 578.203, "measured_dnbr": 1.9357, "rod_position_frac": 0.698142, "boron_ppm": 335.42, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.94144, "tripped": false, "next_target_power_frac": 0.913, "live_pump_flow_cap"...
6,073.0984
specimens/train/xenon-train-19.json
xenon-train-20
train
deep_curtailment
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.361e-05, "doppler_pcm_per_k": -2.5762, "moderator_pcm_per_k": -22.6985, "boron_worth_pcm_per_ppm": -8.2046, "rod_bank_worth_pcm": 7534.37, "flux_at_rated_n_cm2_s": 29317716612889.445, "peaking_factor_fq": 2.2873, "initial_boron_ppm": 286.87, "initial_pump_flow_frac": 1.0, "history_equilib...
[ 0.876, 0.876, 0.876, 0.876, 0.7853, 0.6817, 0.617, 0.617, 0.617, 0.617, 0.617, 0.617, 0.617, 0.617, 0.617, 0.7311, 0.8615, 0.943, 0.943, 0.943, 0.943, 0.943, 0.943, 0.943 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.875997, "measured_tavg_k": 581.5938, "measured_dnbr": 2.1342, "rod_position_frac": 0.716935, "boron_ppm": 349.933, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.91342, "tripped": false, "next_target_power_frac": 0.876, "live_pump_flow_ca...
4,581.5232
specimens/train/xenon-train-20.json
xenon-train-21
train
pump_derate
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.36e-05, "doppler_pcm_per_k": -3.0642, "moderator_pcm_per_k": -32.3612, "boron_worth_pcm_per_ppm": -8.3787, "rod_bank_worth_pcm": 6320.45, "flux_at_rated_n_cm2_s": 31676392729598.46, "peaking_factor_fq": 2.2214, "initial_boron_ppm": 288.39, "initial_pump_flow_frac": 1.0, "history_equilibri...
[ 0.917, 0.917, 0.917, 0.917, 0.7679, 0.5975, 0.491, 0.491, 0.491, 0.491, 0.491, 0.491, 0.491, 0.491, 0.491, 0.6359, 0.8015, 0.905, 0.905, 0.905, 0.905, 0.905, 0.905, 0.905 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.917001, "measured_tavg_k": 578.4898, "measured_dnbr": 1.7173, "rod_position_frac": 0.563306, "boron_ppm": 359.959, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.8843, "tripped": false, "next_target_power_frac": 0.917, "live_pump_flow_cap...
4,048.5325
specimens/train/xenon-train-21.json
xenon-train-22
train
demand_surge
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.586e-05, "doppler_pcm_per_k": -2.1518, "moderator_pcm_per_k": -29.5682, "boron_worth_pcm_per_ppm": -8.7491, "rod_bank_worth_pcm": 6992.89, "flux_at_rated_n_cm2_s": 28655670371666.703, "peaking_factor_fq": 2.368, "initial_boron_ppm": 366.588, "initial_pump_flow_frac": 1.0, "history_equilib...
[ 0.891, 0.891, 0.891, 0.891, 0.7692, 0.63, 0.543, 0.543, 0.543, 0.543, 0.543, 0.543, 0.543, 0.543, 0.543, 0.6694, 0.8138, 0.904, 0.904, 0.904, 0.904, 0.904, 0.904, 0.904 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.891, "measured_tavg_k": 581.4102, "measured_dnbr": 1.9442, "rod_position_frac": 0.640097, "boron_ppm": 351.859, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.85887, "tripped": false, "next_target_power_frac": 0.891, "live_pump_flow_cap":...
5,813.5793
specimens/train/xenon-train-22.json
xenon-train-23
train
deep_curtailment
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 3.192e-05, "doppler_pcm_per_k": -2.964, "moderator_pcm_per_k": -24.7055, "boron_worth_pcm_per_ppm": -8.1543, "rod_bank_worth_pcm": 7374.75, "flux_at_rated_n_cm2_s": 31279692998532.684, "peaking_factor_fq": 2.2144, "initial_boron_ppm": 343.789, "initial_pump_flow_frac": 1.0, "history_equilib...
[ 0.912, 0.912, 0.912, 0.912, 0.8028, 0.678, 0.6, 0.6, 0.6, 0.6, 0.6, 0.6, 0.6, 0.6, 0.6, 0.7204, 0.858, 0.944, 0.944, 0.944, 0.944, 0.944, 0.944, 0.944 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.912004, "measured_tavg_k": 579.147, "measured_dnbr": 2.0444, "rod_position_frac": 0.614891, "boron_ppm": 262.041, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.88033, "tripped": false, "next_target_power_frac": 0.912, "live_pump_flow_cap...
4,465.1993
specimens/train/xenon-train-23.json
xenon-train-24
train
pump_derate
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.573e-05, "doppler_pcm_per_k": -2.4282, "moderator_pcm_per_k": -29.3807, "boron_worth_pcm_per_ppm": -7.2887, "rod_bank_worth_pcm": 6632.0, "flux_at_rated_n_cm2_s": 28161324757644.34, "peaking_factor_fq": 2.3698, "initial_boron_ppm": 265.888, "initial_pump_flow_frac": 1.0, "history_equilibr...
[ 0.936, 0.936, 0.936, 0.936, 0.8145, 0.6757, 0.589, 0.589, 0.589, 0.589, 0.589, 0.589, 0.589, 0.589, 0.589, 0.6999, 0.8267, 0.906, 0.906, 0.906, 0.906, 0.906, 0.906, 0.906 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.935998, "measured_tavg_k": 581.1453, "measured_dnbr": 1.6624, "rod_position_frac": 0.635099, "boron_ppm": 203.276, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.96691, "tripped": false, "next_target_power_frac": 0.936, "live_pump_flow_ca...
4,501.3399
specimens/train/xenon-train-24.json
xenon-train-25
train
demand_surge
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.711e-05, "doppler_pcm_per_k": -2.9369, "moderator_pcm_per_k": -32.5765, "boron_worth_pcm_per_ppm": -8.4833, "rod_bank_worth_pcm": 6247.09, "flux_at_rated_n_cm2_s": 28703791601086.457, "peaking_factor_fq": 2.2279, "initial_boron_ppm": 261.766, "initial_pump_flow_frac": 1.0, "history_equili...
[ 0.929, 0.929, 0.929, 0.929, 0.7823, 0.6148, 0.51, 0.51, 0.51, 0.51, 0.51, 0.51, 0.51, 0.51, 0.51, 0.6542, 0.819, 0.922, 0.922, 0.922, 0.922, 0.922, 0.922, 0.922 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.928996, "measured_tavg_k": 578.9519, "measured_dnbr": 1.8443, "rod_position_frac": 0.792619, "boron_ppm": 226.493, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.95758, "tripped": false, "next_target_power_frac": 0.929, "live_pump_flow_ca...
6,143.5425
specimens/train/xenon-train-25.json
xenon-train-26
train
deep_curtailment
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 1.952e-05, "doppler_pcm_per_k": -2.1996, "moderator_pcm_per_k": -30.6132, "boron_worth_pcm_per_ppm": -8.4427, "rod_bank_worth_pcm": 6855.14, "flux_at_rated_n_cm2_s": 28630975477474.023, "peaking_factor_fq": 2.2756, "initial_boron_ppm": 332.168, "initial_pump_flow_frac": 1.0, "history_equili...
[ 0.902, 0.902, 0.902, 0.902, 0.7795, 0.6395, 0.552, 0.552, 0.552, 0.552, 0.552, 0.552, 0.552, 0.552, 0.552, 0.6885, 0.8445, 0.942, 0.942, 0.942, 0.942, 0.942, 0.942, 0.942 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.902001, "measured_tavg_k": 581.0273, "measured_dnbr": 1.9209, "rod_position_frac": 0.702971, "boron_ppm": 323.64, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.93341, "tripped": false, "next_target_power_frac": 0.902, "live_pump_flow_cap...
5,039.3589
specimens/train/xenon-train-26.json
xenon-train-27
train
pump_derate
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.723e-05, "doppler_pcm_per_k": -2.8702, "moderator_pcm_per_k": -24.2984, "boron_worth_pcm_per_ppm": -8.0507, "rod_bank_worth_pcm": 7544.4, "flux_at_rated_n_cm2_s": 31176082289050.543, "peaking_factor_fq": 2.1897, "initial_boron_ppm": 264.952, "initial_pump_flow_frac": 1.0, "history_equilib...
[ 0.891, 0.891, 0.891, 0.891, 0.7863, 0.6667, 0.592, 0.592, 0.592, 0.592, 0.592, 0.592, 0.592, 0.592, 0.592, 0.7155, 0.8568, 0.945, 0.945, 0.945, 0.945, 0.945, 0.945, 0.945 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.890996, "measured_tavg_k": 578.8345, "measured_dnbr": 1.7892, "rod_position_frac": 0.830889, "boron_ppm": 278.713, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.86785, "tripped": false, "next_target_power_frac": 0.891, "live_pump_flow_ca...
4,596.1532
specimens/train/xenon-train-27.json
xenon-train-28
train
demand_surge
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.271e-05, "doppler_pcm_per_k": -2.3278, "moderator_pcm_per_k": -27.955, "boron_worth_pcm_per_ppm": -7.773, "rod_bank_worth_pcm": 6336.81, "flux_at_rated_n_cm2_s": 30608231539246.285, "peaking_factor_fq": 2.2703, "initial_boron_ppm": 295.724, "initial_pump_flow_frac": 1.0, "history_equilibr...
[ 0.877, 0.877, 0.877, 0.877, 0.765, 0.637, 0.557, 0.557, 0.557, 0.557, 0.557, 0.557, 0.557, 0.557, 0.557, 0.6767, 0.8135, 0.899, 0.899, 0.899, 0.899, 0.899, 0.899, 0.899 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.877001, "measured_tavg_k": 581.1484, "measured_dnbr": 1.9922, "rod_position_frac": 0.66839, "boron_ppm": 280.744, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.85377, "tripped": false, "next_target_power_frac": 0.877, "live_pump_flow_cap...
5,193.5474
specimens/train/xenon-train-28.json
xenon-train-29
train
deep_curtailment
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.198e-05, "doppler_pcm_per_k": -2.1774, "moderator_pcm_per_k": -26.0235, "boron_worth_pcm_per_ppm": -8.9848, "rod_bank_worth_pcm": 6242.41, "flux_at_rated_n_cm2_s": 29469930141346.504, "peaking_factor_fq": 2.2734, "initial_boron_ppm": 269.631, "initial_pump_flow_frac": 1.0, "history_equili...
[ 0.902, 0.902, 0.902, 0.902, 0.7603, 0.5983, 0.497, 0.497, 0.497, 0.497, 0.497, 0.497, 0.497, 0.497, 0.497, 0.6401, 0.8037, 0.906, 0.906, 0.906, 0.906, 0.906, 0.906, 0.906 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.901995, "measured_tavg_k": 578.7928, "measured_dnbr": 2.089, "rod_position_frac": 0.570427, "boron_ppm": 278.583, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.87597, "tripped": false, "next_target_power_frac": 0.902, "live_pump_flow_cap...
4,403.7284
specimens/train/xenon-train-29.json
xenon-train-30
train
pump_derate
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.458e-05, "doppler_pcm_per_k": -2.7113, "moderator_pcm_per_k": -30.8135, "boron_worth_pcm_per_ppm": -7.6885, "rod_bank_worth_pcm": 6403.52, "flux_at_rated_n_cm2_s": 29872523966677.45, "peaking_factor_fq": 2.22, "initial_boron_ppm": 294.229, "initial_pump_flow_frac": 1.0, "history_equilibri...
[ 0.916, 0.916, 0.916, 0.916, 0.7725, 0.6085, 0.506, 0.506, 0.506, 0.506, 0.506, 0.506, 0.506, 0.506, 0.506, 0.6558, 0.827, 0.934, 0.934, 0.934, 0.934, 0.934, 0.934, 0.934 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.915998, "measured_tavg_k": 580.9039, "measured_dnbr": 1.7329, "rod_position_frac": 0.688771, "boron_ppm": 217.178, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.94814, "tripped": false, "next_target_power_frac": 0.916, "live_pump_flow_ca...
4,150.6487
specimens/train/xenon-train-30.json
xenon-train-31
train
demand_surge
You run the shift on a 3411 MWt pressurised water reactor: 24 steps of 15 minutes. The real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. Read the board every step and command rod_target_frac (0 to 1), turbine_demand_frac (0.10 to 1.05), pump_flow_frac (0.72 to 1.0...
{"prompt_generation_time_s": 2.778e-05, "doppler_pcm_per_k": -2.6224, "moderator_pcm_per_k": -25.4327, "boron_worth_pcm_per_ppm": -8.283, "rod_bank_worth_pcm": 7439.33, "flux_at_rated_n_cm2_s": 28788962718364.555, "peaking_factor_fq": 2.1996, "initial_boron_ppm": 333.371, "initial_pump_flow_frac": 1.0, "history_equilib...
[ 0.881, 0.881, 0.881, 0.881, 0.7735, 0.6507, 0.574, 0.574, 0.574, 0.574, 0.574, 0.574, 0.574, 0.574, 0.574, 0.6755, 0.7915, 0.864, 0.864, 0.864, 0.864, 0.864, 0.864, 0.864 ]
{"step_index": 0, "steps_remaining": 24, "time_s": 0.0, "measured_power_frac": 0.880997, "measured_tavg_k": 578.8043, "measured_dnbr": 1.9848, "rod_position_frac": 0.635487, "boron_ppm": 421.547, "pump_flow_frac": 1.0, "turbine_demand_frac": 0.9038, "tripped": false, "next_target_power_frac": 0.881, "live_pump_flow_cap...
5,662.3033
specimens/train/xenon-train-31.json

Reactor Xenon: run a power reactor for six hours, one step at a time

40 closed-loop shifts (32 train, 8 validation) on a 3411 MWt pressurised-water reactor, with the plant and the grader as compiled programs you can run offline. Your model reads a control-room board every 15 minutes and sets four controls. Xenon-135 keeps building for hours after a power cut, the real plant has drifted from its published spec, and at an unannounced step the grid and the pumps change. A program recomputes the whole shift and says pass or fail. No LLM judge, no network.

python3 selftest.py                      # 40 oracle shifts and 40 reference shifts re-graded (10 s on an M4 Pro)
python3 delayed_xenon_shock_demo.py      # before and after, on the same plant

Python 3.9+ and nothing else for those two. Binaries for macOS arm64, Linux arm64 and Linux amd64 are in bin/; the runner restores the executable bit a download can drop.

Before and after, on the same plant

delayed_xenon_shock_demo.py runs one controller twice on xenon-val-02. The only difference is whether it keeps an iodine/xenon balance.

Dispatch, of reference Result
Xenon left at its t = 0 value 42.9% fail: 28.5% of rated power off demand at hour 4.75, coolant 7.4 K low at the end
Xenon tracked 99.4% pass
Xenon tracked, plus feedback 100.0% pass

In the first hour the two look the same (within 0.3% of demand). Over all 40 shifts the three pass 1, 32 and 40. The plant does not trip in this demo; it loses power and temperature. Feedback alone, with no xenon model, also passes 40 of 40, so xenon knowledge is one way to solve a shift and not the only one.

What one shift is

Steps 24 of 15 minutes; 5 MB of binaries, 0.02 s to replay a shift
Actions rod_target_frac 0 to 1, turbine_demand_frac 0.10 to 1.05, pump_flow_frac 0.72 to 1.08, boron_rate_ppm_per_min -5 to 5
Observation measured power, coolant temperature and DNBR (biased, lagged, noisy), rods, boron, pump flow, the next demand, live pump and boron limits
Disturbance at a hidden step from 6 to 15: pump derate, demand surge or deep curtailment
Pass no trip, DNBR at or above 1.30, coolant 565 to 595 K, a ready end state, and at least 92% of the reference dispatch
Reward reward 0 or 1, shaped 0 to 1, ten named checks, and a SHA-384 seal chain over every step
Optional tools four component solvers (kinetics, xenon/iodine, thermal and DNBR, reactivity), up to 28 calls

Measured on these 40, with the binaries in this repository: oracle schedules (rounded to 6 decimals) 40 of 40; the reference policy in policies.py 40 of 40; rods held at the start 0; the published plan followed open-loop with a full plant model 0; the best single oracle schedule replayed on the other shifts 0; a proportional tracker 0.

A sister commercial template with the same plant is saturated for frontier models (two models, 8 of 8 rollouts each, n = 8 per model, wide intervals). That is why this one is open: it is a training ramp. No open-weight model has been measured on it yet; results are welcome at team@zerotrustphysics.com.

Train on it

from reactor_env import ReactorEnv
env = ReactorEnv("xenon-train-00"); board = env.reset()
board = env.step(rod_target_frac=0.60, turbine_demand_frac=0.90, pump_flow_frac=1.0, boron_rate_ppm_per_min=0.0)
report = env.grade()
Framework File Tested on
TRL GRPO (environment_factory, 33 lines) quickstart_trl.py trl 1.19, transformers 5.24; one training step with a tiny model
Prime verifiers (vf.ToolEnv family) verifiers_env.py verifiers 0.1.6 (0.2 and later changed the API)
OpenEnv server openenv_app.py openenv-core 0.3.0, over its own client

The answers are in specimens/ (hidden plant state, oracle schedule). Keep that folder out of your agent's sandbox, and report results on val with the specimens unchanged.

Perturb any physical parameter

Nothing here is locked to the 40 shifts. Change a specimen and grade on the changed plant:

python3 perturb.py xenon-val-00 hidden.organ_spec.boron_worth_pcm_per_ppm 1.05 --out mine.json
python3 perturb.py xenon-val-00 hidden.organ_spec.doppler_pcm_per_k 1.10 --rebalance
python3 perturb.py xenon-val-00 "hidden.live_pump_flow_caps.*" 0.95
python3 delayed_xenon_shock_demo.py mine.json

--rebalance keeps the shift starting critical after a reactivity change. A plant outside the model's bounds is refused by name. reference_dispatch_mwh is the original shift's, so compare a perturbed shift with a reference policy run on the same plant. Example: a 5% higher hot-channel factor makes the reference policy fail its DNBR check on xenon-val-00.

Limits

Simulated, lumped-core physics (six delayed groups, iodine and xenon, primary thermal hydraulics, an engineering DNBR correlation). No axial xenon oscillation. Not validated for operating any real plant.

Licence: LICENSE.txt: free for research, evaluation, academic work, benchmarking, and training or experimenting with open-weight models. Commercial production clusters: team@zerotrustphysics.com. Custom physical systems, custom twins, and frontier-hard unseen suites: https://zerotrustphysics.com/offers/

Protocol Company · zerotrustphysics.com · the same plant runs live, as one shared world, at the Vivarium

Downloads last month
-