EpiClock: A family of transformer epigenetic clocks
EpiClock is a family of five transformer models that estimate age from DNA methylation (Illumina 450K / EPIC beta values). All five were trained on an audited set of healthy-control profiles and tested on 40 studies that were never used for training.
These are research models. They are not a medical device and are not validated for clinical decisions.
Results
Test set: 2,830 healthy controls from 40 held-out ComputAge Bench studies (2,699 of them blood). Lower error is better. The interval is a 95% bootstrap over whole studies.
| Model | Parameters | Median abs. error (years) | Mean abs. error | r |
|---|---|---|---|---|
| EpiClock-T | 2.1 M | 3.49 [2.69, 5.07] | 4.85 | 0.917 |
| EpiClock-S | 3.2 M | 3.44 [2.64, 5.05] | 4.83 | 0.919 |
| EpiClock-B | 6.3 M | 3.38 [2.63, 4.94] | 4.84 | 0.917 |
| EpiClock-L | 11.2 M | 3.34 [2.57, 4.86] | 4.78 | 0.918 |
| EpiClock-XL | 48.0 M | 3.42 [2.55, 4.99] | 4.89 | 0.915 |
| Elastic net, same training data | 9,098 weights | 3.27 [2.57, 4.76] | 4.62 | 0.921 |
| Ridge, same training data | 9,098 weights | 3.56 [2.73, 5.19] | 4.89 | 0.917 |
Published clocks on the same test samples, restricted to the same 9,098-CpG panel:
| Clock | Median abs. error (years) |
|---|---|
| Horvath V2 (skin and blood) | 4.18 |
| Horvath V1 (pan-tissue) | 5.37 |
| Lin | 7.57 |
| PhenoAge (83% of its CpGs are in the panel) | 8.03 |
| Hannum | 8.38 |
What these numbers mean
- The family is more accurate than the published clocks in this benchmark. The published clocks are handicapped here: CpGs they need that are outside the panel are filled with reference values.
- The family does not beat an elastic net trained on the same data. Elastic net scores 3.27 y; the best family member scores 3.34 y.
- Model size made no measurable difference. The five intervals overlap almost completely, and each size was trained once.
- Age accuracy is not biological-age usefulness. In our tests, age acceleration from these models separated patients from same-study controls about as weakly as ridge and Horvath V2 did (AUC around 0.56).
The full comparison, including paired differences and the data audit, is in report.md.
How the models work
- Each CpG is a token: a learned identity, genome context (chromosome, CpG-island relation, regulatory class, position), and its beta value.
- A sample is a random subset of its measured CpGs. Predictions over several subsets are averaged.
- Pre-training hides 25% of the CpGs and reconstructs them, without labels.
- Fine-tuning predicts age as a linear clock over all CpGs (initialised from ridge) plus a correction learned by the transformer.
Training data
- 25,765 profiles with an age and 11,526 without, on a fixed panel of 9,098 CpGs.
- Sources: ComputAge Bench training studies, public GEO series, and the public MethylGPT / EWAS Data Hub collection.
- Every profile passed an audit: no cancer, no other disease, no cell cultures, no study shared with the test set, no copy of a test sample. Counts for every exclusion are at the end of
report.md. - 16,508 of the labelled profiles measure only 3,709 of the 9,098 panel CpGs.
Use
Download epiclock.py and a model folder from this repository, then:
from epiclock import epiclock_predict
# rows = samples, columns = CpG ids (cg...), values = beta in [0, 1]; missing values are allowed
res = epiclock_predict("EpiClock-B/model.pt", betas_dataframe)
ages = res["epigenetic_age"]
The weight files are standard PyTorch checkpoints saved with pickle. Load them only from this repository.
Limitations
- Restricted to a 9,098-CpG panel.
- Trained and tested mostly on blood, and mostly on adults.
- Trained on chronological age in healthy people; it is not a predictor of disease or mortality.
- Expects beta values from 450K or EPIC arrays that have already been processed.
Files
EpiClock-T/โฆEpiClock-XL/: weights (model.pt), configuration and a short card for each model.FAMILY.md: the family table.report.md: the full study report and data audit.epiclock.py: the training and prediction script.
Licence
Released under CC BY-SA 4.0, the same licence as ComputAge Bench, whose studies are the test set and part of the training data.
Data terms
The training data came from many public studies, each with its own terms. Check the terms of ComputAge Bench and of the individual GEO series before redistributing derived data.