Pneumonia detection from chest X-rays (ConvNeXt-Tiny, ONNX)
Binary classifier (pneumonia vs. no pneumonia) for frontal chest radiographs. The ONNX graph includes input normalisation, temperature scaling and a closed-form Grad-CAM, so a single forward pass returns both the calibrated probability and the explanation map. It runs in ONNX Runtime on a server or in the browser.
Live demo (runs in your browser): emir-mutlu/pneumonia-cxr-detection Code, training and evaluation: github.com/emir-mutlu/pneumonia-cxr-detection
Not a medical device. Research and education only; not for diagnosis, triage or treatment.
Files
| File | Content |
|---|---|
model_browser.onnx |
inputs image float32 (N, 1, 224, 224) in [0, 1]; outputs probability (N,) and cam (N, 224, 224) in [0, 1] |
model_meta.json |
decision threshold (0.576), temperature, pre-processing sizes, test metrics |
Weights are stored in float16 and cast to float32 when the session is created. All computation runs in float32, and test AUROC is identical to the float32 model.
Pre-processing
Convert to 8-bit grayscale, then resize the whole image (no crop) to 256 Γ 256 and to
224 Γ 224 with anti-aliased bilinear interpolation (Pillow BILINEAR), and scale to [0, 1].
Predict pneumonia when probability >= threshold from model_meta.json.
import json, numpy as np, onnxruntime as ort
from PIL import Image
meta = json.load(open("model_meta.json"))
img = Image.open("cxr.png").convert("L").resize((256, 256), Image.BILINEAR).resize((224, 224), Image.BILINEAR)
x = (np.asarray(img, dtype=np.float32) / 255)[None, None]
prob, cam = ort.InferenceSession("model_browser.onnx").run(None, {"image": x})
print(prob[0], prob[0] >= meta["threshold"])
Training data and evaluation
Fine-tuned from ConvNeXt-Tiny (ImageNet-22k) on 24,928 images. Two independent sources were combined, with patient-level splits:
- Kermany et al. pediatric chest X-rays (Guangzhou, CC BY 4.0).
- RSNA Pneumonia Detection Challenge 2018 adult chest X-rays (NIH Clinical Center). This set's images map to only 12,233 patients; the splits use the true NIH patient id.
| Held-out test set | Images (patients) | AUROC (95 % CI) | Sensitivity | Specificity | ECE |
|---|---|---|---|---|---|
| Kermany, pediatric | 624 (427) | 0.990 (0.982β0.995) | 0.995 | 0.838 | 0.068 |
| RSNA, adult | 6,133 (2,446) | 0.890 (0.877β0.903) | 0.691 | 0.878 | 0.068 |
CIs come from a patient-clustered bootstrap. Grad-CAM peaks fall inside radiologist boxes for 76.5 % of RSNA test pneumonia images (random point: 12.4 %).
Limitations
- Two hospitals only. Performance elsewhere is unknown; models trained on one hospital lost 0.15β0.21 AUROC on the other.
- One global threshold: sensitivity is much lower in adults (0.69) than in children (0.995). Lower still in patients aged 60+ and on PA views.
- AP (bedside) views carry more disease; part of the adult AUROC comes from view-related cues.
- Labels differ between sources (clinical pneumonia vs. radiographic lung opacity).
Full model card: MODEL_CARD.md.
Citations
Kermany et al., Cell 2018 (doi:10.17632/rscbjbr9sj.2); Wang et al., ChestX-ray8, CVPR 2017; Shih et al., Radiology: AI 2019 (doi:10.1148/ryai.2019180041); Liu et al., ConvNeXt, CVPR 2022.