MikyLanfra's picture
ffdamage-xbd: int8 ONNX, checkpoint, model card
c34fbfa verified
|
Raw History Blame
5.07 kB
metadata
license: cc-by-nc-sa-4.0
library_name: onnxruntime
pipeline_tag: object-detection
tags:
  - building-damage
  - disaster-response
  - remote-sensing
  - dinov3
  - lora
  - centernet
  - fair

ffdamage-xbd

Footprint-free building damage detection from a single post-event satellite image. The model returns one point per building with a detection score and the probability p_damaged that the building is damaged (minor, major or destroyed in xBD terms, against no damage). It needs no building footprints and no pre-event image.

Code, fine-tuning and the HOT fAIr adapter: github.com/MikyLanfra/ffdamage (tag v0.1.0).

Files

file what it is
ffdamage_xbd.onnx serving model, 245 MB: int8 weights on MatMul/Gemm (per channel), convolutions fp32
ffdamage_xbd.pt full PyTorch checkpoint, 810 MB (LoRA merged), used for fine-tuning
meta.json input resolution (gsd_m 0.5), normalisation, stride, default thresholds, licence
SHA256SUMS checksums

Architecture

RGB image, resampled to 0.5 m/px, sides padded to a multiple of 32
  -> DINOv3 ConvNeXt-L encoder (frozen), LoRA rank 16 on the two pointwise (MLP) layers of every block
  -> stage outputs at stride 8, 16, 32, each projected to 256 channels (1x1 conv + GroupNorm + 3x3 conv + GroupNorm)
  -> top-down fusion to stride 8 (upsample + add + 3x3 conv), two 3x3 conv + GroupNorm + GELU layers
  -> three heads on the stride-8 grid:
       heat     1 channel, sigmoid: building-centre heatmap
       offset   2 channels: sub-cell position of the centre
       damage   2-layer MLP on the cell feature, sigmoid: p_damaged
  -> decode: 3x3 max-pool peak finding, top 600 peaks, score cutoff -> points (x, y, score, p_damaged)
  • Encoder: facebook/dinov3-convnext-large-pretrain-lvd1689m. About 200 M parameters in total, almost all in the encoder. The LoRA adapters are merged into the encoder weights in both released files, so they add no inference cost.
  • Training targets follow CenterNet: a Gaussian at each building's centre (polygon centroid, or an interior point when the centroid falls outside), penalty-reduced focal loss on the heatmap, L1 on the offset, and binary cross-entropy on p_damaged at the centre cell. Buildings with unknown damage train detection only.
  • Large images are processed in 1024 px windows with 128 px overlap; each point is kept only from the core of the window that found it, so there are no duplicates across windows.

Training

xBD (xView2), all events, post-event images only, binary damage labels. 1024 px crops at native resolution (about 0.5 m), random flips and 90-degree rotations, batch 4, AdamW at learning rate 1e-4, LoRA rank 16 (alpha 32), 12 epochs with early stopping on validation (patience 4), one L40S GPU, about 2.6 h.

Evaluation (xBD test split, released int8 model)

2,184 test tiles, 80,400 buildings, 19,123 of them damaged. A point counts as a hit when it lies inside a building footprint buffered by 1.5 m; matching is one-to-one by descending score. Cutoffs are chosen on the validation split.

operating point building recall precision damaged recall (p >= 0.5) damage AUROC
best F1 on validation (cutoff 0.30) 0.713 0.775 0.565 0.979

The fp32 model scores the same within 0.01 on every metric (recall 0.707, precision 0.782, AUROC 0.979). The default confidence_threshold 0.306 is the best-F1 cutoff of the fp32 validation run.

Inference cost (ONNX Runtime, CPU, 2 threads): about 3.2 s per 1024 x 1024 window (about 12 s/km² at 0.5 m), peak memory under 2 GB.

Intended use and limits

  • Rapid post-disaster triage on satellite or aerial RGB at about 0.3 to 0.6 m. Points mark buildings to inspect; they are not a damage assessment by themselves.
  • Not trained on drone imagery. For drone data, fine-tune at the drone resolution (gsd_m, lora_rank in the fAIr adapter).
  • Damage is binary; severity levels are not predicted.
  • Harder cases (recall at the best-F1 cutoff, xBD test): dense areas 0.51 against 0.84 in sparse ones, small buildings 0.48 against 0.90 for large ones, and destroyed buildings 0.51 against about 0.73 for the other damage classes. Recall per event ranges from 0.51 (Hurricane Matthew) to 0.90 (Moore tornado).
  • Clouds and haze hide buildings; the model cannot see through them.

Licence

Weights: CC BY-NC-SA 4.0, inherited from the xBD training data (non-commercial). The encoder weights are under the DINOv3 License (see facebook/dinov3-convnext-large-pretrain-lvd1689m). Code: AGPL-3.0-only.

Citation

Developed as part of an EPFL master's thesis (VITA lab), in collaboration with the Humanitarian OpenStreetMap Team (fAIr). Training data: Gupta et al., 2019, xBD: A Dataset for Assessing Building Damage from Satellite Imagery. Encoder: Siméoni et al., 2025, DINOv3.