# OrthoCeph Pro v3.4 β€” Accuracy-First Cephalometric Suite
Single-file, browser-based lateral cephalometric tracing. Everything runs
client-side: patient radiographs never leave the browser; the only network
calls are the ONNX Runtime library and the landmark models (browser-cached
after the first download).
## Models
- **Engine A** β€” HRNet-W32 cepha29 (Aariz dataset), INT8, ~28 MB, loaded
automatically from a public model repo. Published validation:
MRE 1.24 mm, 83.1% of landmarks within 2 mm. All 29 output channels used.
- **Engine B (optional)** β€” HRNet-W48 converted from
MFouda128/Cephalometric-AI-Models, weight-INT8, 63 MB
(`orthoceph_engine_b_int8.onnx`). The checkpoint's own recorded validation:
MRE 1.10 mm, 87.6% within 2 mm. Its undocumented channel order was verified
landmark-by-landmark against Engine A on two real films before integration
(molar channels split by upper/lower position; R/LPM/UPM unused).
To enable: upload `orthoceph_engine_b_int8.onnx` into this Space next to
`index.html` β€” the app then finds it automatically. Or paste any direct
.onnx URL in the app, or load the file per session. When loaded,
Auto-Trace averages both engines per landmark and lowers confidence where
they disagree (shown as A↔B Ξ” in the landmark list). Engine B expects
grayscale input; the app grayscales automatically.
- **Steady mode (TTA)** β€” Engine A runs normal + mirrored passes, averaged;
disagreement lowers confidence.
## Accuracy rules
- **No fake numbers** β€” a measurement is shown only when every landmark it
needs exists. Wits uses a real functional occlusal plane.
- **Calibration gate** β€” mm values are flagged UNCALIBRATED until a 10 mm
ruler calibration is done; calibration recalculates all mm values live.
- **Confidence + verification** β€” per-landmark confidence, Review Queue
(worst first), Verified workflow, JSON records storing AI-vs-final
positions as a validation dataset.
- **Analyses** β€” ABO Focus, Steiner, Downs, Tweed, McNamara, Ricketts,
Holdaway, Jarabak (~48 measurements, 30 landmarks).
- **Print report** β€” clean black-and-white report: patient header,
diagnosis, traced film, all analysis tables.
- **T1/T2 superimposition** β€” cranial base, maxillary, mandibular.
- **DICOM** β€” uncompressed DICOM supported.
## Note
Open this Space over its https address. Opening the file directly from a
phone's file manager (content:// / file://) can restrict WebAssembly and
model downloads β€” manual tracing still works there.