Spaces:
Paused
Download HANDOFF.md from Rachel7/hvac_fable: direct link, hf CLI and curl.
- Browser
- Download file 33 kB
-
https://huggingface.co/spaces/Rachel7/hvac_fable/resolve/main/HANDOFF.md
- Command line
-
hf download hf://spaces/Rachel7/hvac_fable/HANDOFF.md
-
curl -L -o HANDOFF.md https://huggingface.co/spaces/Rachel7/hvac_fable/resolve/main/HANDOFF.md
HVAC Blueprint Analyzer β Handoff
Updated: 2026-07-09 (supersedes all earlier versions of this file). Paste this whole file into a new session so the agent has full context instantly.
Read order for a new agent: (1) this file, top to bottom; (2) PLAN.md
(operative plan β Β§4bβ4j are the running progress log; Β§4i/Β§4j are newest); (3)
analyzer_b/results/error_taxonomy_notes.md (failure families). Ignore
.gsd/ (dead planning system), PUBLICATION_ROADMAP.md / INTEGRATED_PLAN.md
(parallel paper track), and SPRINT_BRIEF.md's day-calendar (rationale valid,
calendar superseded).
0b. SESSION STATE (2026-07-10) β bake-off A/D + snap (read first)
New self-contained bench harness in analyzer_b/hvac_pipeline/:
bench_common.py (logged multi-model calls Anthropic+Gemini, thinking OFF; render
/resize; recipe primitives; strict/loose scorer), run_bakeoff.py (Tracks A+D on
5 gold pages, parallel), snap_experiment.py (local tesseract OCR-snap, no API),
run_track_a_ablation.py (Track-A levers one-at-a-time). Scoring is full-page
300-DPI center-match, strict 0.7x / loose 1.5x unit size (loose ~= recall after
grounding). Full detail: analyzer_b/results/bakeoff_2026_07_10.md; raw under
bakeoff_out/ (summary*.csv, SNAP_SUMMARY.md, TRACK_A_ABLATION.md, per-cell
JSON+PNG, calls/ log = every call+image+cost+time). ~$6 total spent this session.
5 gold pages: 1326 p1 (hard), carroll p8 (dense), carroll p13 (leader-callout),
lewis p2 (VRF), 23042 p8 (clean).
Findings:
- Track D (copy Fable's recipe with a cheap driver, Gemini-flash/Haiku) β SHELVE. Recipe = whole-page + tile-sweep + self gap-hunt. Ceiling ~0.4-0.5 loose on easy pages, ~0 on hard/leader-callout, strict ~0, 30-100 FP/page, erratic (4x4 tiles helped p8/lewis but HURT 23042). Cheap vision on downscaled plans is the wall, not the scaffold. PDF-text/notes-prior steps won't save it.
- Track A (gap-hunt on REAL v31 base) β keep FABLE hunter, DROP Opus. Fable moved recall where it mattered; Opus too conservative (added 0 on hard pages β base FP red boxes made it say "nothing missing"). Base = v31 detections.json, reproduces official v31 recall (1326 p1 = 0/11).
- Track A ablation (add Fable's missing steps ONE AT A TIME) β the useful part:
- A1 = hide the base's ungrounded (non-green) red boxes = THE winner. 1326 p1 loose 0.55->1.0 (found all 11), lewis ->1.0/1.0, ~0 added FP (38->39), cheapest. Root cause: the current track's own FPs were BLINDING the hunter.
- A4 = hi-res per-region hunt = the STRICT lever (only thing that moved 1326 strict, 0->0.36; reads tags at full res). 6x cost; hard/sparse pages only.
- A3 = schedule/"read-the-document-first" checklist = MINOR (+0.09 loose on the hard page, flat else). Keep as ~free prompt line, not a headline lever.
- A2 = snap gap-hunt proposals = no effect (snap helps the BASE, not props).
- carroll p13 stays 0.33/1.0 under EVERY lever = leader-callout body-vs-tag-circle OFFSET (needs leader-line following / body-centering, not hunt/OCR).
- Best config (not yet run combined): A1 + A4(hard pages) + A3(free).
- A1 generalizes WITHOUT gold (the key question): it filters red boxes on the engine's own OCR-GROUNDED flag (= green tier), not truth. Grounded-only precision measured 0.50-1.00 vs 0.16-0.43 raw base -> grounding IS a real gold-free FP signal (matches tier calibration). And it's RECALL-SAFE by construction: filtering only changes what the hunter is SHOWN; all base boxes stay in the output; a hidden true box gets re-proposed + deduped. Worst case degrades to A0, never below. Breaks only where grounding breaks (leader-callout). Deployable form: draw only GREEN boxes as "found", re-hunt yellow/gray. NOT yet validated on a true unseen building (all 5 pages are tuned gold) β first-contact run is the honest next check.
- OCR-snap β helps sometimes, GUARD it. +0.13 strict on lewis (tag on body); NO help on carroll p13 (1/35 grounded); HURT carroll p8 (0.95->0.90, grounded onto wrong text) unless guarded (exact-tag + bounded move). Grounding 25-35%.
- Track C (fable_propose) held per user β highest upside (Fable as clean proposer likely beats all; 0.64-0.73 loose as a mere HUNTER on the hardest page). B stays dead. Next threads: (1) fold A1 green-filter into the ship gap-hunt + validate on an unseen first-contact building; (2) run combined A1+A4; (3) Track C.
0. SESSION STATE (2026-07-08/09) β read this first
Git: on branch session/2026-07-08-thinkfix-validation-withers. PR #1
MERGED to main (v31 scoring, editor delete-persist, Track B kill-switch, first
thinking work). PR #2 OPEN (this branch: thinking-fix + validation, rotate
boxes, Withers, harvest) β do NOT merge until the gold regression finishes
clean (below). Everything committed & pushed.
THE session win β verify thinking-truncation fix (SHIPPED). Gemini 2.5 ran
thinking ON with a 512-tok verify budget β thinking ate the budget β JSON
truncated before tag_text β engine silently kept the schedule-echo guess tag.
Root-caused with a new offline crop bench (verify_crop_bench.py) on 38 E082
units: thinking ON = 0/38 tag reads; thinking OFF = 38/38 family-token correct.
Fixed thinking_budget=0 on _refine_hit_box + title-block reader
(HVAC_VERIFY_THINK=1 reverts). Impact: E082 as-detected tag accuracy 32%β91%,
recall held. This is why the two levers behave now and why Withers was clean.
Levers: Lever B (adaptive-UNKNOWN) SHIPPED default-on (replay danger=0 on
945 boxes). Lever A (pattern re-read) OPT-IN (HVAC_TAG_PATTERN=1) β E082
full-stack ship-check with all fixes on was danger=0, but keep opt-in until
re-validated on the other buildings' FRESH (thinking-fixed) detections.
First-contact ledger grew (all the honest product metric):
- Row 4 E082: 100% recall / 29.7% prec (pre-thinking-fix; 28 relabels needed).
- Row 5 5 Withers: BEST YET β 100% recall, 0.80 prec, 0 relabels, 0 yellow pile (near-zero-touch on unseen bldg; the fixed stack working).
- Row 6 150 Lawrence: RUN DONE, AWAITING USER REVIEW β p2 Cellar + p7 6th
Fl in
outputs\24-0610 - 150 Lawrence St - Mechanical Set\(_prereview\snapshot taken). Preview: p2 = 2 grn/6 ylw/4 gry (harder cellar, has CDU condensers); p7 = 11 grn/1 ylw/8 gry. After review: score indoor-only (CU/ERV/CDU are real equipment but NOT indoor β keep, don't count), ledger row 6, harvest.
BIG new direction β Fable-as-proposer (PLAN.md Β§4j). User showed Claude
Fable one-pass (chat, no tiling/schedule) marking whole floors at ~100%
recall+precision with correct tags+categories. Tested blind on the 2 gold
floors that most broke Gemini: 1326 p1 = 11/11 (Gemini 0/11); Carroll p13
leader-callout = 6/6 (Gemini 4/6 only w/ special code) β all tags correct, 0
FP, correct exclusion of exhaust/vent callouts. PROVEN: recall+tag-ID. NOT yet
measured: coordinate precision (my scores used EYEBALLED centers β strict-center
failed; that's measurement error, loose tol = 11/11 & 6/6). Built
analyzer_b/hvac_pipeline/fable_propose.py (pre-resizes to Claude's high-res
tier per Anthropic's coordinate docs so emitted PIXEL coords map 1:1, asks for
absolute-pixel boxes, scores vs gold). BLOCKED: needs ANTHROPIC_API_KEY in
.env (missing; OpenRouter is set but may lack claude-fable-5 + small cap).
Next: run it on hard+dense+clean floors β measure real precision+cost β Fable
becomes a Track-C proposer (Fable proposes β OCR-snap grounds), maybe deleting
tiling/consensus/verify.
Gold regression (thinking-fix safety gate) β INCOMPLETE, must finish. A
background agent re-ran gold with thinking-fix (levers off, isolate) but STOPPED
after only Lewis. Lewis: 73.3% recall (v31 baseline 60.0%) β UP +13pts, FP
51β23, 0 mistag. No regression; improvement. Carroll/1326/23042 NOT run
(outputs\_gold_thinkfix_carroll empty). MUST finish: re-run those 3 with
HVAC_TAG_PATTERN=0 HVAC_ADAPTIVE_UNKNOWN=0 + --refresh-detections into
outputs\_gold_thinkfix_<b>, score with run_render_failures.py vs the gold
dirs, compare to baseline (Carroll 90.4/1326 70.4/23042 92.1). Only after all 4
hold is the thinking-fix fully cleared and PR #2 mergeable.
Rotatable review boxes SHIPPED (script.js v17). Editor can rotate a box
(circle handle above it, or [/] keys, Shift=15Β°) for angled units. Additive
(angle 0 = unchanged); angle round-trips via a new review-CSV column. GUI needs
server restart + hard-refresh to load.
Stopped background agents (this session): gold-regression (finish it, above) and the old lever-implementation agent (SUPERSEDED β Lever B already shipped; ignore). Two Sonnet harvest agents completed fine (E082+Withers merged to bank, queue at 418).
1. WHAT THIS IS AND WHAT THE USER WANTS
A pipeline that reads mechanical-blueprint PDFs and finds every HVAC indoor unit (tag, location, capacity), plus a FastAPI web GUI (the actual product).
- Commercial product; the web app IS the product. Contractors upload a PDF β units/capacities/CSVs out β review flagged boxes in the browser.
- North star: zero-touch. Review is a maturing-phase crutch.
- RECALL-FIRST, cardinal rule: a missed unit costs trust/money; a false positive costs one glance. NO code path may silently delete a candidate β suspects become flagged review rows (yellow) or gray "noise" rows.
- Decision rule: max center-recall (nearest-center within 0.7Γ unit size); cost + review-rate break ties within ~2 points.
- A/B/C bake-off (~to 2026-07-29): A = Gemini prompts+guardrails (ship path), B = local YOLO, C = cascade (proposer + Flash patch-verify β the cost/zero-touch bet).
- Budget is NOT a constraint but log every paid run (~$50 spent so far, logged in PLAN.md / ledger notes).
- The user reviews boxes personally; her verification is what makes any score real. She runs Kaggle GPU training on her account. Agents may be used for well-specified implementation tasks β use model "sonnet" for those (her request, saves usage); keep diagnosis/vision work in the main session.
2. RESULTS SO FAR (all human-verified)
Gold set (regression testing β NEVER train/harvest/tune on these)
4 buildings, 245 units: Lewis (p2,5 = 15u), Carroll (p4,6,8,11,13,19 = 83u),
1326 (p1,3,5,7 = 71u), 23042 (p3,4,5,8,10 = 76u). CSVs in
analyzer_b/ground_truth/_gold_*/; no-train list analyzer_b/gold_buildings.txt
(also bars 355/Dean β old tuning set, NOT valid unseen gold).
| Config (17 gold pages) | Lewis | Carroll | 1326 | 23042 | TOTAL | FP | F1 | $ |
|---|---|---|---|---|---|---|---|---|
| strict v26-era | 13.3% | 51.8% | 66.2% | 3.9% | 39% | 29 | 0.52 | $6.13 |
| v30_inclusive | 60.0% | 90.4% | 80.3% | 69.7% | 79.2% | 445 | 0.44 | $14.66 |
| v31 taxonomy prompts (SHIP) | 60.0% | 90.4% | 70.4% | 92.1% | 83.3% | 499 | 0.43 | ~$13.65 |
v31 scored 2026-07-05 (PLAN.md Β§4e) and independently re-scored 2026-07-07 with identical numbers. 23042 solid-bar clause worked (+22.4 pts, p3/p8 100%). β 1326 p1 (Cellar) collapsed 80.3%β0/11 despite 31 preds on the page β now 27% of all gold FNs, THE top diagnosis target. F1 β₯0.52 commitment still unmet (0.43): levers = 1326-p1 diagnosis, mistag hardening, Track C.
Standing commitment: precision work must bring F1 back β₯0.52 at ~79% recall. β The 23042 solid-bar prompt clause was derived from gold β gold is no longer pristine for Track A prompt tuning; the first-contact ledger (below) is the honest generalization metric now.
First-contact ledger (analyzer_b/results/first_contact_ledger.csv) β THE product metric
Every NEW building is scored once, human-verified, BEFORE any fix derives from it; then it joins the training pool. Never re-score after fixes.
| Building | Config | Recall | Precision | Notes |
|---|---|---|---|---|
| 72-01 Queens Blvd (18 fl) | v26-era | 92.9% | 57.2% | 22 units missed; 216 FPs deleted |
| 554 W 46th (2 pg) | v31 ship | 100% | 29.6% | green tier PERFECT (8/8); all junk contained in yellow/gray |
| 527 Grand Ave (2 pg) | v26-era CACHE | 100% | ~100% | easy building, June cache β old-config datapoint |
Tier calibration (the zero-touch pathway β evidence to date)
GREEN (OCR-grounded) boxes are ~99β100% precise everywhere measured. Green COVERAGE varies: 100% on well-labeled buildings (554), incomplete where labels are odd (Queens fl28 had 7 real units in yellow). Policy: auto-accept green, review yellow, skim/bulk-delete gray. Proposed next lever (designed, not built): pages with HIGH snap-rate β demote UNKNOWN bodies to gray (adaptive-UNKNOWN, error_taxonomy_notes.md).
3. ENGINE/GUI STATE (all fixes live; GUI engine IS analyzer_b/analyze_blueprint_b.py)
Fix series F1βF8 + later work β details in PLAN.md 4bβ4g and file comments:
- F1 flag-don't-drop (verify rejects β status
noise, conf 0.3, gray dashed; GUI "Delete noise (N)" button; Approve-all & bulk-yellows SKIP noise). - F2 two-question verify (
_refine_hit_box: unit-present? + read-the-tag; mismatch never rejects). FP-family negatives mined from Queens deletes are in that prompt (grilles "(250) SG-1", room text, keynote circles, shafts, bare "A/C", fixtures). - F3/F8
_schedule_quarantine(junk entries leave vocabulary; >30% junk β whole schedule distrusted + auto-switch to inclusive prompt). - F6 UNKNOWN unit bodies (leader-callout plans; skips snap; verify reads tag).
- Solid-bar clause (23042-style small dark bars, stacked dual-floor labels).
- Outdoor guardrail wired in-engine: ACCU-/AC-CU-/CUH- demoted to noise
(
_nonindoor_family), measured FP β20 recall Β±0 on Carroll. - Prefix-aware snap (
_match_wanted_tag): schedule 'AC-C' grounds on printed 'AC-C-8', adopts fuller tag, lands orange. Unit-tested. - F7 multi-floor sheets, end-to-end: titles "3RD-4TH", "10TH & 11TH",
"THIRD THRU SIXTH" β plan pages with
floors_covered/floors_listmanifest columns (_parse_floors_covered, 11 patterns tested); engine summary multiplies (ΓN shown); GUIbuild_resultEXPANDS a multi-floor sheet into one row per real floor (verified: 554 p6 β floors 3β7 Γ7 units; 527 p5 β floors 2β4 Γ18); manifest floor_name beats stale CSV names; floor_number parsed from name not page. - Title-block reader v2 (the user's 3-step plan, VALIDATED): (1) 350-DPI
fitz-CLIP OCR of right strip + bottom-right corner + bottom strip;
(2) sheet-number parsing (
M-303.00) β newsheet_nomanifest column; (3) Gemini-Flash fallback on the title-block strip when no INFORMATIVE standard title (bare "MECHANICAL (PLAN) (FILED)" = uninformative β_UNINFORMATIVE_TITLE; that gate bug initially masked the fallback).HVAC_CLASSIFY_LLM=0disables. Result on 554 W 46th: 0 β 12 plan pages, all floors correct, p6 auto-detected "3RD TO 7TH" Γ5. ~$0.01/failing page. - Floor-name fallback no longer glues FLOOR to numbers across newlines (527 "Floor 44" ghost) and "PARTIAL 5TH" parses fine ("Page 35" explained).
- GUI: upload β
loadReview(uploadTaskId)surfaces cached results instantly;_out_dir_forstrips the<uuid>_upload prefix (ends the 270-Bergen fragmented-dirs bug β re-uploads reconnect to their results). - Symbol Bank tab complete (approve/reject/skip, box adjust, keyboard
a/r/s, progress): types incl.
multi_position_ahu; "Other" β custom type text persisted toanalyzer_b/symbol_types.jsonand future dropdowns. Queueanalyzer_b/harvest/bank_queue.json(352 entries / 34 exemplars from Queens + 554 + 527); decisions inbank_decisions.json; approved crops βanalyzer_b/symbol_crops/<type>/+symbol_library.json. User approved Queens+554 exemplars; 12 from 527 possibly still pending β check bank_decisions.json. - Track B dataset SHIPPED:
analyzer_b/hvac_pipeline/build_dataset_typed.pyβC:\hvac_work\dataset_typed_v1(949 tiles + 3368 flip-n-slide augmented; floor-level split; hard negatives; class 0=indoor_unit, ids 1β3 reserved; type-metadata sidecar) +C:\hvac_work\kaggle_upload_v1.zip(434.7 MB, REBUILT with POSIX zip paths β Kaggle rejects backslashes) +kaggle_run_v1.py(trains yolov8n COCO control vs yolov8n-doclaynet main; "YOLO26n" does not exist in ultralytics 8.4.54). User is uploading/running it on Kaggle T4 β expect backruns/{ctrl_yolov8n,main_doclaynet}/weights/best.pt.
4. IMMEDIATE QUEUE FOR THE NEXT SESSION (in order)
NEW as of 2026-07-09 (do these first β details in Β§0):
- A. Finish the gold regression (Carroll/1326/23042 with thinking-fix, levers off) β confirm no recall drop β clears the thinking-fix β PR #2 mergeable. Lewis already improved (60β73.3%).
- B. Score 150 Lawrence (row 6) once the user reviews it (indoor-only). Then harvest.
- C. Fable-as-proposer: get
ANTHROPIC_API_KEY, runfable_propose.pyon 1326 p1 / Carroll p13 / a dense floor (Carroll p8) / a clean floor β measure real coordinate precision + $/floor β decide if it becomes the Track-C proposer. This is the highest-upside open thread. - D. Then the queued precision work: verify crop-tightness (exact-seq reads were 18/38 β 1800px crop holds neighbor tags), schedule template-row parser, 1326-p1 dense-cluster diagnosis (unique-instance-label prompt test), Track C.
Historical DONE items (this + prior sessions) below for context:
- β
DONE 2026-07-07 β v31 scored (turned out a 2026-07-05 session had already
scored it and logged to PLAN.md Β§4e; re-run reproduced identical numbers,
Β§2 table updated,
_v31_engine_frozen.pydeleted). Original instructions kept below for the command pattern:outputs/_v31_lewis|_v31_carroll|_v31_1326|_v31_23042hold 2/6/4/5 detection jsons. Per building:(PDFs:.\.venv\Scripts\python.exe analyzer_b\hvac_pipeline\run_render_failures.py ` --pred "outputs\_v31_carroll" ` --gold analyzer_b\ground_truth\_gold_417_carroll ` --pdf "raw_pdfs\23092024 - 417 CARROLL ST. - MECHANICAL.pdf" ` --use-json --out "outputs\_failure_sheets\v31_carroll"11 Lewis Ave HVAC Design - DOB 8-9-22.pdfβ two spaces β,1326 Mechanical Plans Received 2,5,2016(1) (2).pdf,New plan - 23042 - Mechanical(06.28.24).pdf.) Fill the Β§2 table, update PLAN.md Β§4e; expect 23042 recall to jump (solid-bar clause) and F1 β β₯0.52. NOTE the v31 runs used the frozen snapshotanalyzer_b/_v31_engine_frozen.pyβ delete it after scoring. - β
DONE 2026-07-07 β task #10 shipped: script.js delete paths (button,
Del/d key, delete-noise) now MARK
action='delete', deleted=trueinstead of splice; drawEditor/boxAt/updateNoiseCount/approveAll skip deleted; save payload carries them; index.html bumped to ?v=15; review_mining.py mines corrections_log.csvresult=deletedrows (deduped by page/id/x/y). Verified: py_compile + node --check pass; live mining run unchanged on existing data (no deleted rows exist yet). NOTE: no bulk-approve-yellows handler exists in script.js (server endpoint exists, frontend never calls it). Needs a hard-refresh + server restart to take effect. Original spec: already writes anyactionsent). In public/script.js:deleteSelBtn, Delete/d-key, anddeleteNoiseBtnmust MARK boxes (action='delete', deleted=true) instead ofsplice;drawEditor+boxAt+updateNoiseCountskipb.deleted;approveAllBtnmust skip deleted; save then carries delete rows β engine--apply-reviewrecords them in corrections_log.csv (the durable FP evidence β review CSVs get rewritten to survivors). Bump script.js?v= in index.html (currently 14). ALSO: extend review_mining.py to mine corrections_log.csvresult=deletedrows (dedupe by page/id/x/y β the log appends per save) since CSVs lose delete rows after apply. - β
DONE 2026-07-07 β E082 reviewed by user + scored: ledger row 4 = 100%
recall / 29.7% precision (38 real, 90 deleted, 0 added). Tiers: green 9/9,
orange 4/4, noise 11/11 junk β auto-accept-green evidence now 4-for-4.
Delete persistence worked live (90 delete rows). NEW LEVER DISCOVERED:
per-floor sequential tag pattern (AC-10-1..31 / AC-C-1..6) β see Β§4 item 5
and error_taxonomy_notes. Harvest/bank-merge ran same day. Was:
β³ RUN DONE 2026-07-07, AWAITING USER REVIEW β E082 first-contact executed
on p13 (Cellar) + p18 (10th Fl), $1.74, out dir = GUI stem dir
outputs\20260415-E08201001-...(NOT_fc_e082β classify artifacts copied over so the GUI reconnects;_prereview/snapshot taken). p13 = 39 boxes, p18 = 89 boxes. After her review: score via review_mining β ledger row 4 β harvest + bank merge. Original spec: First-contact on "20260415-E08201001-Mechanical_100% Construction Documents.pdf" (never analyzed; 2026-era set). CLASSIFY IS DONE (2026-07-07): the new title reader found 30 plan pages of 46, every floor named, multi-floor sheets auto-detected (p16 "6TH-8TH TYPICAL" Γ3, p23 "16TH-17TH" Γ2, piping twins p30/p37). β NEW STRUCTURAL PATTERN: duplicate floor series β every floor appears TWICE: a DUCTWORK plan (M-5xx, pages 13β26) AND a PIPING plan (M-6xx, pages 27β40), plus a stray M-219 "19TH" (p6). Counting units across both series would DOUBLE the building; the pipeline has no concept of this yet. The product eventually needs series de-duplication or user series selection. RECOMMENDED first-contact pages: p16 (6TH-8TH ductwork Γ3 β typical + exercises F7) and p32 (10TH piping) β one per series also reveals which series carries the unit tags, informing the de-dup design. Manifest ready β checkoutputs/_fc_e082/classify_log.txt+ pages_manifest.csv. Pick 2 plan pages (one typical + one dense/weird), run v31 ship config:(~$2). BEFORE the user reviews: snapshot the pre-review CSVs (copy$env:HVAC_TILE_WORKERS='12'; $env:HVAC_FAST_OCR='1'; $env:HVAC_VERIFY_DEBUG='1'; $env:PYTHONIOENCODING='utf-8' .\.venv\Scripts\python.exe analyzer_b\analyze_blueprint_b.py "raw_pdfs\20260415-E08201001-Mechanical_100% Construction Documents.pdf" ` --pages "<p1>,<p2>" --dpi 300 --tile-size 1800 --runs 2 --consensus 2 ` --all-tags --recall-prompt --no-yolo -y --out-dir "outputs\_fc_e082"floor_*_review.csvto a_prereview/subdir) so deletes are reconstructable until #2 lands. User verifies in the GUI β score with review_mining logic β ledger row 4 β then harvest (harvest_review_crops.py --pdf ... --reviews ...) +prep_bank_candidates --csv <new harvest csv> --out <temp>+ append-merge into bank_queue.json (see the merge snippet pattern in this session: namespace colliding ids). - β
DONE 2026-07-07 β KILL-SWITCH FIRED: Track B shelved (pending user
sign-off). Gold tile set built (
build_gold_tiles.pyβ C:\hvac_work
gold_tiles_v1, 3,136 tiles, 245/245 GT sanity-checked, overlay-verified). bench_detectors on both Kaggle checkpoints (best_ctrl_yolov8n.pt / best_main_doclaynet.pt in C:\hvac_work), center-match, imgsz 1024:model R@.25 P propR@.05 propFP ctrl_yolov8n 0.14 0.34 0.20 530 main_doclaynet 0.05 0.07 0.14 967 vs same-corpus Kaggle holdout 0.94/0.98 β catastrophic cross-building generalization cliff, NOT a harness bug (labels sanity-checked; models simply don't fire on unseen drafting styles). Per-tile scoring double- counts overlap-tile GT (430 tile-instances of 245 units) so unit-level propR might reach ~0.3 with SAHI fusion β still nowhere near the 0.85 kill-switch. **Track C falls back to "Gemini proposes, Flash patch-verifies"** per plan. Retraining with much more data (public datasets + auto-labeled own plans, per recalibration memory) is the only revival path β not this sprint. Original spec: When the user delivers Kaggle weights ( best.ptΓ2, likely inC:\hvac_work): score proposal-recall on gold β `bench_detectors.py --model "name=path\best.pt" --center-match --proposal-recall` with a YOLO-format gold test set (may need building gold tiles first β check bench_detectors --test-images expectations). Kill-switch: proposal-recall@0.05 < ~0.85 β shelve B; C falls back to "Gemini proposes, Flash patch-verifies". - LEVER STATUS 2026-07-08: implemented (tag_pattern.py + engine
_apply_review_burden_levers+ replay_demotion_rules.py; 37 unit tests pass) but replay gate FAILED on E082: danger=17 β Lever A's local-OCR re-read fails on exactly the labels live snap already failed on (rescued=0), so demote-on-failed-reread graybins real units. Both levers flipped to OPT-IN (HVAC_TAG_PATTERN=1 / HVAC_ADAPTIVE_UNKNOWN=1 to enable; default OFF). Upside real: 65 junk pre-demoted on E082. Fix path: (1) β DONE 2026-07-08 β crop bench (verify_crop_bench.py) DISPROVED anchor-echo; REAL bug = Gemini-2.5 thinking-ON truncates the 512-tok verify JSON before tag_text β engine keeps the schedule-echo guess. Bench/38 units: thinking OFF 38/38 family-token, 18/38 exact, 0/28 echoed; thinking ON 0/38. FIXED thinking_budget=0 on _refine_hit_box + title reader (HVAC_VERIFY_THINK=1 restores); kept anchor prompt. E082 re-run validation β outputs_e082_thinkfix. Next: re-run replay β Lever A danger should collapse (correct tags ground before levers) β un-bench Lever A. (2) verify_debug still logs only boxes/outcome, add tag_text/unit_present; (3) similarity-score protection before demotion; (4) exact-seq reads 18/38 β 1800px crop holds neighbor tags, TIGHTEN verify radius; (5) Flash-Lite A/B on the bench; (6) title reader needs re-verification (same fix, no bench). LEVER B ISOLATED REPLAY (2026-07-08): danger=0 on ALL 17 pages / 945 boxes (win=51). SHIPPED default-ON (HVAC_ADAPTIVE_UNKNOWN=0 to disable); Lever A stays opt-in. Follow-up: replayinertcolumn shows 1 on every page yet win>0 on some β display/accounting inconsistency, verify win magnitudes before trusting them (danger=0 is trustworthy: harness cleanly split A's 17 vs B's 0). Then, in order: (a0) schedule TEMPLATE-ROW parser (user-identified on E082's schedule: designation "AC-FLOOR-#" = explicit per-floor tag grammar- uniform wall-mounted model/capacity; parse placeholder designations into
a
tag_templatecache entry β per-page wanted-tag prefixes for snap + verify + pattern-lever seeding + type/capacity metadata; kills the AC-A schedule-echo at the source β full design in error_taxonomy_notes.md); (a) tag-pattern conformance lever (NEW, from E082: mine grounded tags per page for<FAM>-<floor-token>-<seq>patterns; when β₯3 grounded tags fit β demote non-conforming yellows/UNKNOWN to gray, keep/boost conforming, and report sequence GAPS as possible-miss flags β on E082 p18 this alone would have cut yellows ~75% and flagged the AC-10-21 gap); (b) adaptive-UNKNOWN rule (E082 adds UNKNOWNΓ37 deleted / 0 kept evidence); (c) "covers floors N-M" GUI input; (d) Track C cascade assembly (Gemini proposes + Flash patch-verifies β YOLO proposer is dead per item 4); bake-off = A vs C.
- uniform wall-mounted model/capacity; parse placeholder designations into
a
5. ENVIRONMENT GOTCHAS (read before running anything)
- Windows 11, PowerShell (no
&&; backtick continuation; quote spaced paths; multi-linepython -cafter;fails β write scratchpad .py files). Engine output piped through Select-Object may exit 255 benignly β redirect to a log file instead (*> log.txt). - Engine python:
.venv\Scripts\python.exe. GUI server: SYSTEM python (python server.py, port 8000, browse http://localhost:8000 β NOT 0.0.0.0). Split is intentional. - After editing public/: bump
script.js?v=Nin index.html + hard-refresh. After editing server.py/modules/: restart the server. - Heavy IO β
C:\hvac_work(OneDrive Errno 22), foreground. .envhas GEMINI_API_KEY (monthly cap raised) + OPENROUTER (small daily cap). β Repo root junkHVAC-Blueprint-Analyzer*(U+F05C filenames) includes a stray.envwith LIVE keys (GROQ/FEATHERLESS possibly unique) β gitignored; do NOT delete without the user; NEVER git add.- Git: everything is uncommitted and a STALE
.git/index.lockfrom 2026-07-01 blocks writes. User paused committing ("hold off on git") β when she asks: remove the stale lock (verify no git process first),git add -A, scan staged for.env|pdf|png|zip|pt, commit with the Claude co-author trailer. - Session limits kill background agents/runs silently β on any resume, VERIFY artifacts (not reports) before assuming work landed.
- Costs: full-page detection ~$0.35β0.90/page; 2-page first-contact ~$1β2; gold sweep ~$10β15; Flash title reads ~$0.01/page. Log in PLAN.md.
- Detection caches: re-running WITHOUT
--refresh-detectionsreuses per-floor caches (free). The GUI reuses caches too β 527's "first contact" accidentally measured June's cache; NOTE the config in every ledger row.
6. FILE MAP
PLAN.mdβ operative plan + progress log (Β§4bβ4g) + costs. Source of truth.analyzer_b/analyze_blueprint_b.pyβ THE engine (GUI runs it via modules/pipeline.py ENGINE). Key fns:_detection_prompt_inclusive,_refine_hit_box,_qwen_verify_refine,_schedule_quarantine,_local_ocr_snap+_match_wanted_tag,_review_status,_dedupe_cross_location,_parse_floors_covered,_ocr_titleblock_text,_sheet_number_from_text,_llm_titleblock_title,_UNINFORMATIVE_TITLE,_nonindoor_familydemotion at final-assembly.analyzer_b/versions.pyβ config registry;v30_inclusive= ship knobs (v31 = same knobs + current prompts; prompts live in the engine).analyzer_b/hvac_pipeline/β review_mining.py (is_human_verified= THE shared human-touched rule), harvest_review_crops.py, prep_bank_candidates.py, run_render_failures.py (gold scorer), ab_guardrails.py, bench_detectors.py, build_dataset_typed.py, flip_n_slide.py, error_taxonomy.py.analyzer_b/results/β first_contact_ledger.csv (PRODUCT METRIC), error_taxonomy_notes.md, review_mining.csv, LEADERBOARD.md (OLD tuning-set numbers, don't trust for generalization).analyzer_b/harvest/β fp_crops/, bank_candidates/, bank_queue.json, bank_decisions.json, harvest_*.csv, contact sheets.modules/pipeline.pyβ DEFAULT_RECIPE (recall_prompt: True = ship),build_result(multi-floor expansion),_out_dir_for(uuid strip),_manifest_floor_info.modules/symbol_bank.pyβ bank backend.server.py+public/β FastAPI + frontend (Review tab: box editor, noise band; Bank tab). script.js cache-bust currently ?v=14.outputs/<building>/β review CSVs (human edits live here; apply-review rewrites them to survivors), detections.json (rewritten on apply too!), corrections_log.csv (DURABLE human-decision record), pages_manifest.csv (now with floors_covered/floors_list/sheet_no), schedule cache.raw_pdfs/β ~24 buildings. Verified: Queens, 554 W 46th, 527 Grand. Next candidates: E08201001 (in flight), 5 Withers, 150 Lawrence (note: those two have June-era caches β fresh--refresh-detectionsruns needed for v31 ledger rows). Skip 270 Bergen fragments + 355/Dean.
7. WHAT THE USER DOES (never do these for her)
- Verify boxes (first-contact reviews, bank approvals). No score is real until she confirms. Her conventions: box = unit body + tag when adjacent (body only on leader-callout plans); product boxes need not be pixel-tight, training boxes should be.
- Kaggle GPU runs (in progress β kaggle_upload_v1.zip; steps: attach dataset, GPU T4, Internet ON, paste kaggle_run_v1.py, set INPUT slug line, Run All; bring back both best.pt + printed recalls).
- Decisions: git commits, junk-dir deletion, ship sign-offs, big spends.
- Pending user follow-ups she flagged: wall-mounted units exist on 554's unreviewed pages (review one page later for type diversity in training); 12 bank exemplars from 527 may be pending approval.