baseball-engine / docs /MOTION_PLAYER_API.md
github-actions[bot]
Automated Deploy: 3ea2037ab7d55d5b498f7e2ea0336818fc24f725
fe40b87
|
Raw History Blame
22.1 kB

Motion-player backend API

Contract 1.0 · SAM and GVHMR adapters · native-body refinement · 23 October 2026

For app implementation, start with the frontend integration guide, updated 19 October 2026. It covers migration, authenticated video playback, multi-swing range playback, measurement cards and skeleton/graph synchronization.

Base URL: https://modventures-baseball-engine.hf.space. Use the existing server Bearer key for every /v1/ request. Keep that shared credential in your app's backend. This separate API preserves the current engine/product/SAM contracts. It exports actual corrected motion for an interactive skeleton player, using SAM 3D Body or GVHMR through the same routes. A client frontend and animated body mesh are outside this version. Existing callers continue to default to SAM.

For the AI coach's strict three-measurement payload, see single-swing coach export. Add player information and an optional reviewed contact_frame to the existing request; previous options and motion artifacts are preserved.

Choose the model

Set model inside the existing form-data options JSON:

{"model": "sam3d", "annotated_videos": true}

or:

{"model": "gvhmr", "annotated_videos": true}

Every recording fact, polling route and artifact format stays the same. Read GET /v1/motion-analyses/capabilities: models lists both adapters with their individual configured status and setup reason. One unavailable model does not disable the other. An unconfigured selection returns 503 before reserving a job. Unknown model names return 422. There is no silent fallback to another model. GVHMR needs a licensed SMPL-X neutral file; see GVHMR setup.

To compare the same recording, first run either model, then submit a new analysis with the completed manifest's source_video.asset_id in the source_asset_id form field and the other model in options. This reuses the original bytes without another upload. Alternatively change model through /revisions; it creates a new immutable revision and runs fresh inference. The parent artifacts remain unchanged. This API does not use Gemini.

Both adapters declare the same 20 canonical names. Their native anatomical definitions differ: SAM uses MHR70 landmarks; GVHMR uses SMPL-X joint centers and its explicitly documented ear/foot surface landmarks. The SMPL-X adapter has its own batting-corrected-points-smplx-v1 measurement definition revision, retaining the companion document's formulas. Do not pool numbers from different models as interchangeable measurements or use a model switch as evidence of player improvement. Each manifest records the actual native indices/definitions.

Routes

Method and path Purpose
POST /v1/motion-analyses Multipart video or existing source asset; returns 202.
GET /v1/motion-analyses/{job_id} Status, progress, immutable revision and failure reason.
GET /v1/motion-analyses/{job_id}/result Completed manifest and artifact URLs.
GET /v1/motion-analyses/{job_id}/coach-payload Opt-in single-swing measurement payload matching the coach's contract 1.0.
GET / HEAD /v1/motion-analyses/{job_id}/artifacts/{name} Authenticated, checksummed artifact; byte ranges supported.
POST /v1/motion-analyses/{job_id}/revisions Recording-fact/correction/event patch into a new immutable revision.
DELETE /v1/motion-analyses/{job_id} Cancel/delete this execution and its retained files.
GET /v1/motion-analyses/capabilities Model/configuration, limits and retention.
GET /v1/motion-analyses/input-schema Recording options schema.
GET /v1/motion-analyses/output-schema Manifest, motion-frame, projection-frame and coach-payload schemas.

Upload and polling

In form-data, video is a File and options is Text containing JSON. Alternatively omit video and send source_asset_id from a completed motion manifest. Exactly one source is required; remote URLs and server paths are not accepted.

Example options, only when these recording facts are known:

{
  "model": "sam3d",
  "handedness": "right",
  "handedness_source": "Uploader supplied",
  "camera_stability": "fixed_verified",
  "timing": {"kind": "unretimed", "source": "Original speed verified by uploader"},
  "single_swing": false,
  "annotated_videos": true
}

Other options reuse the SAM input: upright-image camera intrinsics; documented up_vector and pitcher_vector; uniform scale_factor and its source; lead_foot, athlete_box, correction settings and reviewed windows in decoded source-frame indices. scale_status defaults to model_estimated; calibrated requires a calibration source; unknown exports model units and disables absolute distances/linear speeds. Height alone is not camera calibration. source_mirrored records the source information; the adapter does not silently flip/relabel it. camera.distortion optionally supplies five Brown–Conrady coefficients in [k1,k2,p1,p2,k3] order, calibrated in the upright displayed image convention. Fitting and projections use the same distortion model; the source video is not warped. With no coefficients the pinhole assumption remains explicit. Calibrated ground translation is not supplied. Missing calibration does not prevent motion export. Coaching/LLM calls are disabled on this path.

When up_vector is omitted/null, the shared pipeline estimates it from sampled video frames using GeoCalib. Reliable estimates populate effective calculation inputs, with up_source and diagnostics in coordinates.up_estimation; submitted inputs stay unchanged. Explicit vectors take priority. Unreliable estimates stay unknown, and camera stability, scale and timing checks still apply. A declared pitcher direction may be supplied before vertical is resolved. See automatic camera-up estimation for coordinates, acceptance checks, FE labels and the up_estimation.enabled opt-out.

When no pitcher vector or floor points are supplied, both models automatically estimate hitting direction from a stable batting setup followed by hand and torso movement (automatic_body_swing_direction_v2). No plate, field markings, handedness, camera intrinsics, or user direction input is required. The existing automatic up estimate is used. Missing or conflicting evidence leaves direction unknown without stopping the job. This is an approximate batting direction based on the setup hip line, not a measurement of an unseen pitcher's location. The output names this reference estimated_batting_axes, records the supporting frames in coordinates.pitcher_estimation, and flags affected measurements with pitcher_reference_estimated_from_body_motion and target_alignment_unverified. Accuracy on real labelled videos has not been validated.

For an optional manual override, send pitcher_floor_points with source_frame_index, near_batter and toward_pitcher in upright source pixels. This uses supplied camera calibration marked camera.calibration_status: "calibrated" and supplied or accepted estimated up. Explicit pitcher vectors take priority. Returned coordinates.pitcher_estimation records the source, assumptions and rejection reasons. See floor-point direction and FE integration.

Native-body refinement

New motion jobs enable refinement.enabled by default. Existing engine and SAM coaching APIs retain their processing paths. To compare against the previous correction, create a revision with {"refinement":{"enabled":false}}; the native model outputs are reused when their integrity and recording facts still match.

Processing is: native reconstruction → independent RTMW image observations and forward/backward optical-flow checks → native-rig fitting → acceptance checks → one corrected sequence for motion, measurements, projections, and annotation. SAM now retains its native shape/motion parameters and exact MHR landmark regressor. GVHMR fits SMPL-X parameters in its own isolated interpreter. Their anatomical definitions remain separate; model outputs are never averaged.

Each continuous identity/model segment uses a shared robust body-shape estimate. The optimizer changes native pose and camera translation, using soft image constraints, initializer priors and timestamp-aware temporal penalties. RTMW landmarks are homologous observations, not asserted identical anatomical joint centres or calibrated visibility/depth scores. LK checks both neighboring images; only reliable forward/backward cycles can contradict a detector, and either neighbor can corroborate it. A tracking failure alone does not invalidate a 2D observation. These checks adjust weights and never create a missing landmark. Shape/scale priors do not establish physical calibration. Native rig constraints and initializer priors apply; no unsupported anatomical angle limits are invented.

Fitting optimizes one continuous native-parameter trajectory per valid segment. Native rig evaluation and gradient recomputation use batches of eight frames, bounding mesh activation memory without splicing separately fitted trajectories. Vector–Jacobian products use the full trajectory's point gradients, including temporal terms across batch boundaries; this is the same gradient as one complete native evaluation, verified by a cross-boundary gradient-equivalence test. Overlapping quality windows accept/reject regions of that same fit; they do not introduce processing seams or derivative gaps by themselves. Missing observations, identity/model boundaries, clock gaps and actual raw/refined switches remain derivative boundaries. No pose is generated through a missing interval. Rapid movement receives weaker temporal regularization. Image-supported fast hand peaks are checked for timing and speed distortion. Accepted fitted points bypass the old independent-joint filter so their rig geometry is preserved. Rejected windows retain native predictions; strong image disagreement additionally disables the conflicting joints.

pipeline.refinement (also in quality.correction.whole_body_refinement) records accepted/fallback frame counts, per-window reasons, settings, implementation hash, image evidence and diagnostics. Each frame reports whole_body_refinement_accepted; joint reasons distinguish an accepted fit from native fallback. Fallback is not presented as verified motion. Native parameters, fitting candidates, evidence and raw debug arrays remain private.

Robust background image displacement checks a declared static camera. Multiple contradictory observations set declared_static_camera_conflict; calculation inputs then use moving/uncertain camera semantics and dependent measurements are withheld. Original submitted inputs and effective calculation_inputs are both recorded, so measurements remain reproducible. Background displacement is not a calibrated camera trajectory or ground frame. No unsupported foot locking or field direction is inferred.

Each supported continuous trajectory is fitted again with temporal-weight factors 0.5 and 2.0. Summary stability gives the resulting minimum/maximum in the metric's own units only when both alternative fits and the complete swing are supported. Otherwise it supplies not_evaluated with a reason. This is sensitivity to regularization, not a confidence interval or independent accuracy validation. No numerical uncertainty is fabricated for unsupported sections. Acceptance defaults are configurable engineering gates, not established biomechanical error limits.

Defaults are eight native frames/batch, 48 frames/quality window, eight context frames/side and 25 optimizer steps per continuous fit. Three fits are performed for each supported continuous segment. This adds GPU work; the actual inference/refinement runtime must be evaluated on the deployed GPU. Options and bounds are published in /input-schema. Progress includes image_motion_evidence, loading_native_refinement, and whole_body_refinement.

The 3D initializer anchor has an explicit body-relative scale (initializer_scale_body_fraction, default 0.03), rather than an implicit metre of uncertainty. This is a regularization parameter, not a measured accuracy bound. Candidate selection respects the pose-adjustment trust region throughout optimization. Shared-shape normalization and subsequent pose adjustment are reported separately; long-limb diagnostics compare the same pose's normalized body, not a constant shoulder/torso span. Native MHR parameters must reproduce every fitted source frame within the arithmetic tolerance before fitting.

Short person-detection losses can be recovered through consistent predicted box motion, size and torso appearance. Maximum recovery gap defaults to 0.2 s of video time. Ambiguous overlapping people are never recovered on clothing alone. Lost frames remain gaps. tracking settings are versioned native-inference inputs.

The 202 response includes analysis_id, job_id, analysis_revision, parent_job_id, status_url, result_url and retention_hours. The first analysis ID equals its job ID. Poll the supplied status URL until completed or failed; active work reports processing. Queued/uploading/cancelled states are explicit. Completed results can contain unavailable individual measurements. No usable motion, fewer than four decoded frames, invalid timestamps, ambiguous athlete selection or inference failure produces a failed job with a reason.

Multiple plausible athletes require athlete_box. Tracking uses conservative box, motion and appearance agreement, not biometric identity recognition. Bounded short losses may be recovered; ambiguous crossings and uncertain frames remain unusable.

Manifest and artifacts

The manifest declares the ordered 20-joint anatomical skeleton, actual native mapping, bones, fixed coordinates, scale interpretation, source orientation, timing map, model/checkpoint hashes, adapter/correction revisions and settings, measurement-definition version, quality segments and artifact integrity details.

Artifact name Content
motion motion.jsonl: one corrected joint record per decoded source frame.
source Original uploaded video bytes, with orientation/display dimensions.
measurements measurements.json: four groups' summaries and graph series.
events events.json: windows, baseline, stride/foot plant and speed peaks.
quality quality.json: segments, corrections and identity/accuracy limitations.
projections projections.jsonl: projections of the same corrected joints, when valid.
annotated_rotation, annotated_timing, annotated_posture, annotated_stance Optional MP4s with group skeleton overlays; no bottom panel.
mesh Unavailable with reason animated_mesh_second_phase.

Each artifact includes status, format, media type, authenticated relative URL, size, SHA-256 and expires_at, or an unavailable reason. All referenced files are ready before completion. Only allowlisted artifacts are downloadable; raw inference/debugging arrays remain private. Follow returned URLs with the Bearer header. Source videos and artifacts expire after the configured retention (24 hours by default), cancellation or deletion. Ephemeral hosting can lose jobs on redeployment; configure persistent BASEBALL_DATA_ROOT for durable replay.

Replay and alignment

Every frame includes source-frame index, original PTS/time base, elapsed video_time_s, elapsed capture_time_s or null, segment_id, every declared joint, separate root translation and frame quality. Every joint has a finite position or explicit null, status, null confidence when the model supplies none, and reason codes. Gaps and filter boundaries remain explicit; there is no intentional source-frame skipping, invented confidence or gap interpolation.

GVHMR additionally records its 30-Hz temporal conditioning grid and source-time mapping. The grid uses physical capture time when known, otherwise playback time. Rotation parameters use SO(3) interpolation back to source timestamps; affected joints carry interpolated status and explicit provenance, and dependent metrics record interpolated input. This does not fill missing athlete tracks or source clock gaps. Long sequences use bounded windows with context; window boundaries start new segments and are excluded from derivative evidence. The effective GVHMR timing sample spacing is at least 33.333 ms even when the source has more frames; resampling does not invent high-speed timing evidence. The gvhmr options expose batch size, window/context sizes and input-2D quality thresholds. These scores gate model inputs; they are not calibrated 3D confidence. Background camera-rotation failures remain unusable frames. Camera rotation and the model's native global prediction do not become calibrated ground coordinates.

Use video time to synchronize with the original recording, including variable cadence. Capture time is for physical rates; constant slowdown and explicit maps are recorded. Never assume index divided by nominal FPS is the timeline. Never interpolate replay across segment/gap boundaries. Client playback interpolation must not become measurement evidence.

Positions are hip-relative, in a fixed right-handed orientation. With supplied field vectors, X is toward the pitcher, Z is declared up and Y = Z × X. With only up, the starting hip axis supplies the fixed horizontal reference. Otherwise the real camera axes (right/down/away) are exported without claiming gravity or field direction. Native model scale remains estimated unless calibrated.

root_translation_included is false. The separate root is a model-estimated camera root in the same export axes/units, not ground motion. For projection:

camera_point = (joint.position + frame.root_translation) @ camera_to_export_rotation
pixel = project(camera_point, projection_frame.camera_intrinsics, optional_camera_distortion)

Add root exactly once. Uniform scale cancels in perspective division. Projections include source IDs/times, per-frame camera intrinsics, upright image dimensions, validity and in-frame flags. Apply declared source orientation once. Raw detected 2D points are not substituted for corrected projections. Overlay videos use those same projections and original playback timing, at most 1280 pixels on the longest side, without audio.

Measurements and events

The existing sam_measurements.py calculator implements the supplied companion document's definitions. Summaries contain metric ID, definition version, value, unit, reference, statistic, baseline, window, exact source samples/times, reasons and interpolation provenance. Series contain shared definitions/units/references and timestamped samples. Event-only values remain summaries; their curve samples use event_summary_only rather than repeating a summary as continuous motion.

Head movement uses the ear midpoint; hand speed uses the wrist midpoint relative to hips. Neither is bat speed, eye tracking or foot pressure. Sampled peak order does not prove onset order/energy transfer. Body points alone do not establish ball contact. Missing ground translation or a segment-mass model leaves ground displacement/COM unavailable. Unknown scale disables cm and m/s values; unknown physical timing disables rates/durations. Joint gaps and correction boundaries block derivative evidence.

The backend exposes a reproduction helper using only public artifacts:

from baseball_batting.motion_export import reproduce_measurements
groups = reproduce_measurements(manifest_dict, "motion.jsonl")

Events identify type, status, source, start/end source samples, revision and reasons. Sources distinguish manual review, pose-estimated windows and sampled speed peaks. Automatic windows remain candidates. An unavailable foot-plant event does not prove that no step occurred.

For one swing, a supplied contact_frame creates a reviewed ball_contact event; without it contact remains unavailable. Player information under athlete enables the separate coach payload, sampled at the reviewed stride/landing/contact frames. It does not change the existing maximum-separation summary. See the request, event definitions and reliability mapping.

Immutable reviewed revisions

Send a JSON patch to the parent's /revisions endpoint. Unchanged options are inherited. Example:

{
  "options": {
    "windows": [{
      "start_frame": 20,
      "end_frame": 150,
      "baseline_frame": 25,
      "forward_start_frame": 75,
      "forward_end_frame": 115,
      "stride_start_frame": 45,
      "landing_frame": 70,
      "source": "Coach reviewed source recording"
    }]
  }
}

The response retains the analysis ID, allocates a new job ID/revision and supplies new URLs. The parent is unchanged. Native inference is reusable after integrity checks when camera/crop/orientation/adapter inputs match. Changing the athlete requires a new analysis using source_asset_id, giving it a new person ID. Changing the reconstruction model, checkpoint, or GVHMR temporal conditioning (clock, camera stability, gap threshold, native settings) prevents inference reuse. Correction-only changes can reuse the selected model's verified native output.

Verification limits

Tests cover joint completeness/mapping, axes/scale, variable cadence/retiming, source/overlay synchronization, public-point reprojection, measurement reproduction, explicit gaps/identity uncertainty, missing wrists, unknown camera/clock/scale, immutable concurrent revisions, source retention, cancellation, authentication, artifact checksums and byte ranges. These check implementation behavior. Hidden depth, anatomical assignment in arbitrary real clips and real-world measurement accuracy still need independent reference data. Smooth replay and image alignment alone do not prove accurate 3D motion.