baseball-engine / docs /SAM_BATTING_API.md
github-actions[bot]
Automated Deploy: 5f5a7796b033a641e2d36ba6ab13a6325199a1a5
ae695bd
|
Raw History Blame Contribute Delete
17.2 kB

Corrected SAM batting API

Test page: /sam-batting. Existing Swing Lab and its endpoints keep their own contracts.

One video runs through person-box tracking, one SAM 3D Body pose model (body and hand decoders), temporal correction, calculations, four annotated videos, and the existing coach service's per-measurement review. The person detector chooses the athlete crop; it does not supply a second skeleton. No bat/ball or Gemini image review runs in this flow. Coaching receives calculated numbers only.

Requests

All /v1/ calls require Authorization: Bearer <BASEBALL_API_KEY>. Keep this key in the app's backend, not in a distributed mobile app. The HTML page accepts it for testing, holds it in memory and sends it only to this server.

Method and path Purpose
GET /v1/sam-batting/capabilities Configuration, queue readiness, limits and schema links
POST /v1/sam-batting/analyses Multipart video file plus one JSON-text options field; returns HTTP 202 and a job ID
GET /v1/sam-batting/analyses/{job_id} Poll status/progress; completed jobs include result_url
GET /v1/sam-batting/analyses/{job_id}/result Four groups, per-swing measurements/coaching, quality flags and video links
GET or HEAD /v1/sam-batting/analyses/{job_id}/videos/{group} Authenticated MP4; supports byte ranges
POST /v1/sam-batting/group-reviews Add/refresh four group scores and coaching from existing measurement groups; no GPU/video upload required
GET /v1/sam-batting/group-review-schema Input/output schemas for refreshing group reviews
DELETE /v1/sam-batting/analyses/{job_id} Cancel and remove the retained recording/results

Group keys: rotation, timing, posture, stance.

Postman: Body → form-data → video type File and options type Text. Example options only if these declarations describe the actual recording:

{
  "timing": {"kind": "unretimed", "source": "Original camera recording; no speed changes"},
  "camera_stability": "fixed_verified",
  "up_vector": [0, -1, 0],
  "up_source": "Camera verified upright and level; approximate vertical",
  "handedness": "right",
  "single_swing": true,
  "coaching": true
}

Image-up is not automatically gravity. An upright, level camera declaration is an explicit approximation, not recovered calibration. Leave vertical unknown for a tilted camera unless you can supply a reliable vector in SAM camera axes. When vertical is known but 3D pitcher direction is unknown, headings use the fixed starting hip axis. Field-forward/lateral stride remain unavailable. An image-left or image-right label cannot supply a full 3D field direction.

Optional fields:

  • camera: fx, fy, cx, cy, source, in upright decoded pixels.
  • pitcher_vector and pitcher_source: a known 3D direction in camera axes.
  • scale_factor and scale_source: a documented uniform correction of SAM's metre-scale estimates. Changing scale alone does not validate depth.
  • lead_foot: left or right; otherwise handedness supplies the conventional lead.
  • athlete_box: [x1,y1,x2,y2] in upright pixels to disambiguate multiple people.
  • windows: up to twenty reviewed, ordered, nonoverlapping swing windows.
  • correction and measurement: explicit algorithm settings; defaults appear in the input schema and the result. They are engineering defaults, not validated universal thresholds or coaching standards.

Reviewed window example (replace every frame number with reviewed values):

{
  "windows": [{
    "start_frame": 0,
    "end_frame": 240,
    "baseline_frame": 20,
    "forward_start_frame": 140,
    "forward_end_frame": 220,
    "stride_start_frame": 90,
    "landing_frame": 150,
    "source": "Reviewed original video"
  }]
}

Without windows, hand-motion peaks propose automatic windows. These are explicitly unreviewed candidates, not verified swing/foot-contact labels. Reviewed stride-start and landing frames are required for stride calculations. A heading or settled pose does not prove ground contact. Corrected-point retention permits forensic review; the current API accepts reviewed windows on a new upload, not an in-place edit.

Set single_swing: true only when the recording contains exactly one swing. This keeps one complete recording window and selects the strongest hand-motion candidate for its estimated forward interval, rather than counting preparation/recovery movements as additional repetitions. This declaration does not validate the forward start/end events. With the default false, the page labels unreviewed intervals motion candidates, not confirmed swings. For a reliable per-swing count in a multi-swing recording, supply reviewed windows. Rotation from baseline ends at the selected window boundary; that boundary is not automatically actual swing completion.

Result contract

Schemas: /v1/sam-batting/input-schema and /v1/sam-batting/output-schema. Published copies: sam-batting-input.schema.json, sam-batting-result.schema.json.

schema_version: "1.1"           # Reads previous 1.0 results too
algorithm_version: "batting-corrected-points-v1"
session_id
model                       # pinned SAM source, weight hashes, precision
correction                  # version, settings, rejection/smoothing counts, bad sections
calculation_settings
coordinates                 # axes, origin, scale and reference sources
capture                     # frame count, clock known, local cadence summary
quality_flags
groups[]
  key, label
  score                       # Estimated coaching score, 0–10; graded aspects and evidence
  coaching                    # Summary, what_went_well, what_needs_work, next_step
  annotated_video           # status, url, checksum, dimensions and duration
  swings[]
    rep, start_frame, end_frame, baseline_frame, window_source
    forward_rotation_sign, lead_foot
    movement_peak_order, peak_order_reason_code
    measurements[]
      key, label, value, unit, statistic, reference
      status                # estimated, partial or unavailable
      reason_code, quality_flags, source_frame_ids, sample_spacing_ms
      formula, accuracy_validated: false
      coaching
        explanation, review, source, model, assessment, reason_code

No raw/corrected joint arrays or per-frame timestamps are returned. Private source-timed trajectories and metric curves drive calculations and video overlays. Frame IDs, scalar movement timing measurements, and cadence metadata remain in the public result so values can be interpreted and inspected. Playback preserves original video timing, including slow motion; physical calculations use declared capture timing. An unknown capture clock withholds physical speeds and durations.

Every metric states its statistic. Hip/shoulder headings are sampled at maximum absolute observed separation; rotation-from-start uses the end of the selected window; lean/head excursions report maximum absolute values, marking incomplete windows partial; stance is sampled at baseline and foot headings at reviewed landing or baseline. Speeds and peak delays require usable continuous forward-window data. Peak order is sorted from observed sampled peak times, never forced into a hip-first pattern. Identical-frame peaks leave order unresolved. Local sample spacing is not an accuracy bound; millisecond formatting does not create finer capture resolution.

Missing data is per metric. Missing wrists do not invalidate usable foot geometry. Return null, not zero, for unavailable measurements. Zero is a valid value. Do not hide an entire group merely because one of its values is unavailable. Show the exact reason and its coaching explanation.

Each group has its own version of the complete recording, without audio, with relevant skeleton markings over the original picture. No bottom information panel or measurement text is added; values remain in the JSON and page cards. The videos use the same corrected 3D points, projected through the matching SAM camera model. Native prediction coordinates never replace failed corrected coordinates. Videos resize to at most 1280 pixels on the longest side.

Correction, geometry and conditional values

SAM's first seventy pred_keypoints_3d points use the pinned MHR-70 mapping. The model's axes/metre conversion is already applied. Camera translation is applied once for rendering, not interpreted as ground displacement. A projection convention check must pass before using a frame. SAM supplies no calibrated per-joint confidence; it stays unknown.

Correction checks finite points, image visibility, consistent person tracking, timestamp gaps, and isolated reversals corroborated by unusual bone length for that recording. It does not reject a point merely for moving quickly. A centered quadratic fit narrows its time support during faster motion. Gaps remain gaps; there is no interpolation. Raw predictions, corrected points, point-validity bits and filter boundaries remain private. Derivatives use the nonuniform three-point formula at the middle sample and never cross gaps or filter boundaries.

The reference definitions are supplied in SAM3D_Batting_Measurements_From_Corrected_Points.md (14 October 2026). We implement line headings/separation, angular and hip-relative wrist speeds, peak timing, torso centerline lean, ear-midpoint displacement, stance/foot headings, and relative stride. A shoulder-line separation is not a clinical spine angle; hand speed is not bat speed; head excursion is not path length or foot pressure.

Ground-relative head/pelvis displacement and absolute stride return missing_ground_reference: this API does not reconstruct validated ground translation. Whole-body center of mass returns missing_mass_model: no complete, population-appropriate segment mass model was supplied. Vertical, pitch direction, capture clock and reviewed stride events have their own missing-data reasons.

The existing coach service is extended for this contract rather than relabelling new metrics as legacy measurements with different definitions. It uses the shared provider configuration and daily usage ledger. Every metric gets a deterministic explanation; optional Gemini text adds short descriptive interpretation for usable values. Invalid/provider-failed notes fall back independently without losing any numbers. Per-measurement explanations remain descriptive. Separate group coaching now gives an estimated AI score out of ten, strengths, points to work on and a next action, using the available values. These are POC coaching judgments, not validated numerical performance benchmarks. The HTML page marks the distinction.

Four group scores and coaching (result version 1.1)

For the app, display groups[i].score.value with score.max_value (ten), then groups[i].coaching.summary, what_went_well, what_needs_work, and next_step. Each coaching point is { "text": "...", "evidence": [...], "source": "coach_agent" }. The backend supplies the exact measurement value, unit, rep, statistic, reference and frame IDs in each evidence item. Do not interpret a null individual metric as a missing group score. Do not display unavailable individual measurements in the player’s main cards; they remain in the complete API result for diagnostics. Zero is a valid score.

The sam-groups-v3 rubric has named aspects for each group:

Group Aspects
Hips and shoulders Hip/shoulder differentiation; rotation through the selected interval
Movement timing Relationships between movement speed peaks; hip-relative hand movement
Posture and head Torso position; hip-relative head movement; ground displacement only if supplied
Stance and stride Starting base geometry; foot orientation; stride only if supplied

Gemini grades each assessable aspect from zero to four: priority for practice, substantial work, developing/mixed, useful pattern with a refinement, or strong pattern to preserve. Python computes round(10 * sum(grades) / (4 * aspect_count), 1). The rubric version, individual grades and supporting evidence are returned. A grade is an AI coaching opinion about the measured pattern, not a population percentile, age comparison, diagnosis, player-ability rating or objective proof of a fault. Temporal claims such as acceleration, deceleration, maintained posture and repeatability cannot be inferred from scalar summaries. Strengths describe supplied geometry/peak relationships; improvement points are practical refinements. Different toe headings are not a proven fault or a demand for matching angles. There are no invented ideal angle/speed bands. More separation, faster movement or smaller head motion is not automatically better. Suggestions can be refinements to try; the agent must not invent a mistake simply to fill a list.

Only non-null available values enter the provider input and cache key. Missing measurements/aspects add neither zeros nor penalties. The remaining aspects are weighted equally. All four groups in the verified example have usable evidence, so all four can receive a score while the twelve missing measurements stay unchanged. Every strength, improvement point and next step cites evidence from its own group; the server resolves those IDs to the original numbers. Cross-group evidence, invented evidence IDs and changed aspect IDs are rejected and retried once. Prose is checked independently: an unsupported paragraph is replaced with a source-defined factual explanation or practical rehearsal suggestion, while valid grades and other paragraphs remain. summary_source, point source, and aspect explanation_source identify coach_agent or rules; the group coaching source is mixed when both occur. This fallback does not invent grades or measurements.

Use the same Bearer key to refresh a saved result without running SAM again:

POST /v1/sam-batting/group-reviews
Content-Type: application/json
Body: { "groups": <groups array from a SAM result> }
Response: { "schema_version": "1.0", "groups": [{ "key": ..., "score": ..., "coaching": ... }, ...] }

Merge those returned fields into the matching original group by key; videos and measurements are unchanged. The HTML page has a refresh button and can open a saved result JSON. Refresh is a measurement-only Gemini call, uses the shared daily budget/cache, and is capped at four MiB, four groups and twenty windows per group. An already configured GPU is not needed for this route. The API never fetches submitted video URLs. The page accepts API media URLs only on its own origin. The preserved 1.0 fields remain usable; new jobs produce the additive 1.1 result.

A provider/key/budget failure does not create a fabricated default score or erase the measurements. Its score stays pending and the refresh route returns a retriable 503 for affected groups with evidence. coaching: false makes no Gemini calls. An entirely empty group cannot support a truthful assessment; that exceptional case is separate from the normal partial-data scoring described above.

Qualitative background, not validation of this scoring rubric: USA Baseball on individual stance choices, MLB’s stance definitions and variation, and WRSSBA’s coaching discussion of stance and turning. These sources do not supply or validate the out-of-ten scoring formula above.

Deployment

The default Docker build includes an isolated Python 3.11/Torch CUDA SAM runtime and the pinned source. It does not embed gated weights or credentials. At startup, tools.start_api prepares normally approved assets using the Space's HF_TOKEN, records their revision/checksums, then starts the API. A configured external BASEBALL_SAM_WORKER_RECORD can reuse an existing worker. BASEBALL_SAM_SKIP_SETUP=1 skips automatic setup. Optional BASEBALL_SAM_MODEL_REVISION pins the provider model commit; otherwise its resolved commit is recorded. Missing access leaves the old API usable and the new upload route returns an explicit 503.

All jobs share the existing single-GPU queue, upload limits, cancellation, timeouts and retention. The default job timeout is 1800 seconds. Full-recording SAM can be slower than sparse event inference; benchmark your GPU and recordings. Source uploads are removed when a job terminates; private arrays, JSON and videos are removed on cancellation or normal retention expiry. Space disk is ephemeral unless persistent storage is enabled. Download results you need to retain.

Verification covers analytic angle/stride/velocity examples, nonuniform timing, translation invariance, missing joints, ambiguous peaks, fast-motion preservation, four-video source timing, API authentication/ranges/integrity and legacy regression checks. These verify implementation behavior; they do not establish real-video measurement accuracy.