omniroute / docs /architecture /RESILIENCE_GUIDE.md
rais133's picture
Deploy OmniRoute to HF Space
923b5bb verified
|
Raw History Blame Contribute Delete
6 kB
---
title: "Resilience Guide"
version: 3.8.18
lastUpdated: 2026-06-09
---
# Resilience Guide
OmniRoute has three distinct but related resilience mechanisms. Each has a different scope and purpose. Keep them separate when debugging routing behavior.
![3-layer resilience model](../diagrams/exported/resilience-3layers.svg)
> Source: [diagrams/resilience-3layers.mmd](../diagrams/resilience-3layers.mmd)
## 1. Provider Circuit Breaker
**Scope:** entire provider (e.g., `glm`, `openai`, `anthropic`).
**Purpose:** stop sending traffic to a provider that is repeatedly failing at the upstream/service level.
**Implementation:**
- Core class: `src/shared/utils/circuitBreaker.ts`
- Wiring: `src/sse/handlers/chatHelpers.ts`, `src/sse/handlers/chat.ts`
- Status API: `GET /api/monitoring/health`
- Reset API: `POST /api/resilience/reset`
- Wrappers: `open-sse/services/accountFallback.ts`
- DB table: `domain_circuit_breakers`
**States:**
- `CLOSED` β€” normal traffic allowed
- `DEGRADED` β€” traffic still allowed, but elevated provider failures are being tracked
- `OPEN` β€” provider temporarily blocked; combo routing skips it
- `HALF_OPEN` β€” reset timeout elapsed; probe request allowed
**Configurable defaults (`open-sse/config/constants.ts`, exposed in Dashboard β†’ Settings β†’ Resilience):**
| Class | Degraded at | Opens at | Reset timeout |
| ------- | ----------- | ----------- | ------------- |
| OAuth | 5 failures | 8 failures | 60s |
| API-key | 7 failures | 12 failures | 30s |
| Local | derived | 2 failures | 15s |
`degradationThreshold` controls when a provider enters `DEGRADED`; `failureThreshold` controls when it opens and is skipped. Local provider profiles are not exposed on the Resilience settings page yet.
**Trip codes:** only provider-level statuses `[408, 500, 502, 503, 504]`. Do NOT trip for account-level errors (most 401/403/429 β€” those belong to cooldown or lockout).
**Lazy recovery:** when `OPEN` expires, `getStatus()`, `canExecute()`, `getRetryAfterMs()` refresh state to `HALF_OPEN`. No background timer needed.
---
## 2. Connection Cooldown
**Scope:** single provider connection/account/key.
**Purpose:** skip one bad key while other connections for the same provider keep serving.
**Implementation:**
- Mark unavailable: `src/sse/services/auth.ts::markAccountUnavailable()`
- Selection: `getProviderCredentials*` in same file
- Cooldown calc: `open-sse/services/accountFallback.ts::checkFallbackError()`
- Settings: `src/lib/resilience/settings.ts`
**Fields per connection:**
- `rateLimitedUntil` β€” timestamp until cooldown expires
- `testStatus: "unavailable"`
- `lastError`, `lastErrorType`, `errorCode`
- `backoffLevel` β€” exponential backoff counter
**Default cooldowns:**
- OAuth base: 5s
- API-key base: 3s
- API-key 429: prefers upstream `Retry-After`/reset headers/parseable reset text
- Backoff: `baseCooldownMs * 2 ** failureIndex`
**Anti-thundering-herd guard:** prevents concurrent failures from over-extending cooldown or double-incrementing `backoffLevel`.
**Terminal states (NOT cooldowns):**
- `banned`
- `expired`
- `credits_exhausted`
These persist until credentials change or an operator resets them. Do not overwrite terminal states with transient cooldown state.
**Lazy recovery:** when `rateLimitedUntil` is past, connection becomes eligible again. On successful use, `clearAccountError()` clears all error fields.
---
## 3. Model Lockout
**Scope:** provider + connection + model triple.
**Purpose:** avoid disabling a whole connection when only one model is unavailable or quota-limited.
**Examples:**
- Per-model quota providers returning 429
- Local providers returning 404 for one missing model
- Provider-specific mode/model permission failures (e.g., Grok modes)
**Implementation:** `open-sse/services/accountFallback.ts` β€” `lockModel()`, `clearModelLock()`, `getAllModelLockouts()`.
### Model Cooldowns Dashboard (v3.8.0)
UI: Settings β†’ Model Cooldowns (`src/app/(dashboard)/dashboard/settings/components/ModelCooldownsCard.tsx`)
Lists active lockouts with: provider, connection, model, reason, expiresAt. Operators can manually re-enable a model from the card.
**REST API:**
- `GET /api/resilience/model-cooldowns` β€” list active lockouts
- `DELETE /api/resilience/model-cooldowns` β€” manual re-enable. Body: `{provider, connection, model}`. Auth: management.
---
## Other Resilience Features
- **14 routing strategies** (priority, weighted, round-robin, context-relay, fill-first, p2c, random, least-used, cost-optimized, reset-aware, strict-random, auto, lkgp, context-optimized) β€” see [AUTO-COMBO.md](../routing/AUTO-COMBO.md).
- **Reset-aware routing** (v3.8.0) β€” prioritizes connections by quota reset time.
- **Background mode degradation** β€” Responses API `background: true` degraded to sync with warning.
- **Dynamic tool limit detection** β€” backs off providers when tool count limits hit.
---
## Debugging
- All keys for a provider skipped β†’ check both circuit breaker state AND each connection's `rateLimitedUntil`/`testStatus`.
- Provider permanently excluded after reset window β†’ code reading raw `state` instead of `getStatus()`/`canExecute()`.
- One key fails, others should work β†’ prefer connection cooldown over circuit breaker.
- Only one model fails β†’ prefer model lockout over connection cooldown.
- State should self-recover but doesn't β†’ check for future timestamp + read path that refreshes expired state. Permanent statuses require manual changes.
---
## TLS Fingerprinting & Stealth
Provider-specific stealth (JA3/JA4, CCH, obfuscation) is separately documented β€” see [STEALTH_GUIDE.md](../security/STEALTH_GUIDE.md).
---
## See Also
- [Architecture Guide](./ARCHITECTURE.md) β€” System architecture and internals
- [User Guide](../guides/USER_GUIDE.md) β€” Providers, combos, CLI integration
- [Auto-Combo Engine](../routing/AUTO-COMBO.md) β€” 6-factor scoring, mode packs