Instructions to use suitch/scan2report-decoder-weighted-oversampled with libraries, inference providers, notebooks, and local apps. Follow these links to get started.
- Libraries
- PEFT
How to use suitch/scan2report-decoder-weighted-oversampled with PEFT:
from peft import PeftModel from transformers import AutoModelForCausalLM base_model = AutoModelForCausalLM.from_pretrained("Qwen/Qwen3.5-4B") model = PeftModel.from_pretrained(base_model, "suitch/scan2report-decoder-weighted-oversampled") - Notebooks
- Google Colab
- Kaggle
Positive weighting + oversampling decoder
Part of the master's thesis From Scan to Report: Detecting, Segmenting and Reporting Findings in Chest CT (code: https://github.com/Switchharsh/Switchharsh-From_Scan_to_Report_Master_Thesis; thesis: https://github.com/Switchharsh/Switchharsh-From_Scan_to_Report_Master_Thesis/tree/main/thesis).
Decoder trained with affirmative-only content weighting (weight 7.6) and label-balanced oversampling (power 1.0, cap 25), 24k samples / 1500 steps, embedding-norm matching and projector lr 1e-3. The best supervised training recipe in the thesis.
| condition | CRG | macro-F1 |
|---|---|---|
| real scan | 0.3957 | 0.2524 |
| another patient's scan | 0.3622 | 0.1391 |
Three-seed mean: CRG 0.3946 +- 0.0215, real-minus-mismatched gap +0.0325 +- 0.0209. The weighting only helps together with oversampling (matched-budget 2x2: interaction +0.0585 CRG, single seed per cell).
How it fits together
- Input: the 8x8x8 FlexiCT token grid of a chest CT (
flexict/tokens8, 864-dim per token) from CT-RATE. projector.pt: MLP (864 -> 2560 -> 2560, LayerNorm) that maps the visual tokens into the LLM embedding space.adapter_model.safetensors+adapter_config.json: LoRA (r=16, alpha=32) on Qwen/Qwen3.5-4B.- Loading and generation code (model wrapper, data, evaluation): https://github.com/Switchharsh/Switchharsh-From_Scan_to_Report_Master_Thesis (
ctbench/rgen/model.py,evaluate.py). The adapter is not a stand-alone chat model: the projector and the FlexiCT tokens are required. - Task instruction used in every run:
Write the findings and impression for this chest CT.Greedy decoding, at most 512 new tokens.
Evaluation protocol
1,000 patient-sampled CT-RATE validation cases; CRG (micro) and macro-F1 with the RadBERT label reader (suitch/radbert-english-ctrate-classifier, threshold 0.5). Control = another patient's scan tokens (mismatched). Numbers are from the thesis From Scan to Report: Detecting, Segmenting and Reporting Findings in Chest CT.
Limitations / licence
Research use only, not for clinical use. Trained on CT-RATE (CC BY-NC-SA 4.0), so the weights are released under the same non-commercial terms. Reports can contain false findings; see the thesis for the error analysis.
- Downloads last month
- -