Label-to-report assembler (stage 2)

Part of the master's thesis From Scan to Report: Detecting, Segmenting and Reporting Findings in Chest CT (code: https://github.com/Switchharsh/Switchharsh-From_Scan_to_Report_Master_Thesis; thesis: https://github.com/Switchharsh/Switchharsh-From_Scan_to_Report_Master_Thesis/tree/main/thesis).

Stage 2 of the two-stage pipeline. It writes a report from a list of findings and does not see the scan. Prompt: Write the findings and impression for this chest CT. + Findings present: ... Findings absent: ... (the 18 CT-RATE labels).

labels given CRG macro-F1
reference labels (upper bound) 0.8099 0.8948
FlexiCT attention classifier, t=0.60, raw text 0.4968 0.4990
same, clipped + coverage post-processing 0.5176 0.5298
another patient's classifier labels 0.3494 0.2021

How it fits together

  • Input: the 8x8x8 FlexiCT token grid of a chest CT (flexict/tokens8, 864-dim per token) from CT-RATE.
  • projector.pt: MLP (864 -> 2560 -> 2560, LayerNorm) that maps the visual tokens into the LLM embedding space.
  • adapter_model.safetensors + adapter_config.json: LoRA (r=16, alpha=32) on Qwen/Qwen3.5-4B.
  • Loading and generation code (model wrapper, data, evaluation): https://github.com/Switchharsh/Switchharsh-From_Scan_to_Report_Master_Thesis (ctbench/rgen/model.py, evaluate.py). The adapter is not a stand-alone chat model: the projector and the FlexiCT tokens are required.
  • Task instruction used in every run: Write the findings and impression for this chest CT. Greedy decoding, at most 512 new tokens.

Evaluation protocol

1,000 patient-sampled CT-RATE validation cases; CRG (micro) and macro-F1 with the RadBERT label reader (suitch/radbert-english-ctrate-classifier, threshold 0.5). Control = another patient's scan tokens (mismatched). Numbers are from the thesis From Scan to Report: Detecting, Segmenting and Reporting Findings in Chest CT.

Limitations / licence

Research use only, not for clinical use. Trained on CT-RATE (CC BY-NC-SA 4.0), so the weights are released under the same non-commercial terms. Reports can contain false findings; see the thesis for the error analysis.