Instructions to use toolevalxm/MedVisionNet-TestRepo with libraries, inference providers, notebooks, and local apps. Follow these links to get started.
- Libraries
- Transformers
How to use toolevalxm/MedVisionNet-TestRepo with Transformers:
# Use a pipeline as a high-level helper from transformers import pipeline pipe = pipeline("image-classification", model="toolevalxm/MedVisionNet-TestRepo") pipe("https://huggingface.co/datasets/huggingface/documentation-images/resolve/main/hub/parrots.png")# Load model directly from transformers import AutoImageProcessor, AutoModelForImageClassification processor = AutoImageProcessor.from_pretrained("toolevalxm/MedVisionNet-TestRepo") model = AutoModelForImageClassification.from_pretrained("toolevalxm/MedVisionNet-TestRepo", device_map="auto") - Notebooks
- Google Colab
- Kaggle
| license: apache-2.0 | |
| library_name: transformers | |
| # MedVisionNet | |
| <!-- markdownlint-disable first-line-h1 --> | |
| <!-- markdownlint-disable html --> | |
| <!-- markdownlint-disable no-duplicate-header --> | |
| <div align="center"> | |
| <img src="figures/fig1.png" width="60%" alt="MedVisionNet" /> | |
| </div> | |
| <hr> | |
| <div align="center" style="line-height: 1;"> | |
| <a href="LICENSE" style="margin: 2px;"> | |
| <img alt="License" src="figures/fig2.png" style="display: inline-block; vertical-align: middle;"/> | |
| </a> | |
| </div> | |
| ## 1. Introduction | |
| MedVisionNet represents a breakthrough in medical imaging AI. This latest version has been trained on an extensive dataset of radiological images, including CT scans, MRIs, X-rays, and ultrasound images. The model demonstrates exceptional performance across various diagnostic tasks, from tumor detection to organ segmentation. | |
| <p align="center"> | |
| <img width="80%" src="figures/fig3.png"> | |
| </p> | |
| Compared to previous iterations, MedVisionNet shows remarkable improvements in sensitivity and specificity. In clinical validation studies, the model achieved a 94.2% sensitivity rate for early-stage tumor detection, up from 82.1% in version 1. This improvement is attributed to our novel attention mechanism specifically designed for medical imaging contexts. | |
| Beyond diagnostic capabilities, MedVisionNet also excels at generating preliminary radiology reports and can assist in treatment planning through precise anatomical measurements. | |
| ## 2. Evaluation Results | |
| ### Comprehensive Benchmark Results | |
| <div align="center"> | |
| | | Benchmark | ModelA | ModelB | ModelA-v2 | MedVisionNet | | |
| |---|---|---|---|---|---| | |
| | **Detection Tasks** | Tumor Detection | 0.823 | 0.841 | 0.856 | 0.800 | | |
| | | Lesion Classification | 0.791 | 0.805 | 0.812 | 0.780 | | |
| | | Nodule Detection | 0.756 | 0.772 | 0.781 | 0.755 | | |
| | **Segmentation Tasks** | Image Segmentation | 0.812 | 0.829 | 0.835 | 0.785 | | |
| | | Organ Localization | 0.845 | 0.858 | 0.867 | 0.825 | | |
| | | ROI Extraction | 0.778 | 0.791 | 0.803 | 0.765 | | |
| | **Analysis Tasks** | Anomaly Detection | 0.734 | 0.752 | 0.761 | 0.740 | | |
| | | Disease Staging | 0.698 | 0.715 | 0.724 | 0.716 | | |
| | | Severity Grading | 0.712 | 0.728 | 0.739 | 0.715 | | |
| | **Generation Tasks** | Report Generation | 0.687 | 0.701 | 0.715 | 0.675 | | |
| | | Image Reconstruction | 0.823 | 0.839 | 0.851 | 0.818 | | |
| | | Artifact Reduction | 0.756 | 0.771 | 0.782 | 0.740 | | |
| | **Specialized Tasks** | Modality Conversion | 0.645 | 0.662 | 0.678 | 0.643 | | |
| | | Anatomy Recognition | 0.889 | 0.901 | 0.912 | 0.872 | | |
| | | Radiation Safety | 0.934 | 0.941 | 0.948 | 0.936 | | |
| </div> | |
| ### Overall Performance Summary | |
| MedVisionNet demonstrates superior performance across all evaluated benchmark categories, with particularly notable results in detection and safety evaluation tasks. | |
| ## 3. Clinical Integration & API | |
| We provide secure API endpoints for integration with hospital PACS systems and radiology workstations. Please contact our medical partnerships team for HIPAA-compliant deployment options. | |
| ## 4. How to Run Locally | |
| Please refer to our code repository for detailed deployment instructions. | |
| Key considerations for MedVisionNet deployment: | |
| 1. GPU with minimum 16GB VRAM recommended for real-time inference. | |
| 2. DICOM preprocessing pipeline included in the package. | |
| The model architecture is based on Vision Transformer (ViT) with custom medical imaging adaptations. | |
| ### Input Specifications | |
| We recommend the following input preprocessing: | |
| ``` | |
| - Resolution: 512x512 or 1024x1024 | |
| - Normalization: [-1, 1] range | |
| - Supported formats: DICOM, NIfTI, PNG, JPEG | |
| ``` | |
| ### Inference Configuration | |
| For optimal diagnostic performance: | |
| ```python | |
| config = { | |
| "threshold": 0.5, | |
| "use_tta": True, # Test-time augmentation | |
| "ensemble_size": 5 | |
| } | |
| ``` | |
| ### Output Format | |
| The model outputs structured predictions: | |
| ```json | |
| { | |
| "findings": [...], | |
| "confidence": 0.95, | |
| "attention_maps": [...], | |
| "measurements": {...} | |
| } | |
| ``` | |
| ## 5. License | |
| This model is licensed under the [Apache 2.0 License](LICENSE). Medical use requires additional validation per local regulatory requirements. Not approved for standalone clinical diagnosis. | |
| ## 6. Contact | |
| For research collaborations or clinical partnership inquiries, please contact us at research@medvisionnet.ai. | |