Instructions to use MedMLX/musclemap-mlx with libraries, inference providers, notebooks, and local apps. Follow these links to get started.
- Libraries
- MLX
How to use MedMLX/musclemap-mlx with MLX:
# Download the model from the Hub pip install huggingface_hub[hf_xet] hf download MedMLX/musclemap-mlx --local-dir musclemap-mlx
- Notebooks
- Google Colab
- Kaggle
- Local Apps Settings
- LM Studio
- Atomic Chat
|
Download technical.md from MedMLX/musclemap-mlx: direct link, hf CLI and curl.
- Browser
- Download file 8.04 kB
-
https://huggingface.co/MedMLX/musclemap-mlx/resolve/main/technical.md
- Command line
-
hf download hf://MedMLX/musclemap-mlx/technical.md
-
curl -L -o technical.md https://huggingface.co/MedMLX/musclemap-mlx/resolve/main/technical.md
8.04 kB
| # MuscleMap v1.4 implementation and qualification | |
| ## Reference contract | |
| The source reference is [MuscleMap/MuscleMap at | |
| 35a2138](https://github.com/MuscleMap/MuscleMap/tree/35a2138a4a3a63be713bae5584632ffc6433b960), | |
| with the contrast-agnostic wholebody v1.4 checkpoint and JSON configuration from | |
| [Zenodo record 21929873](https://zenodo.org/records/21929873). Both source and | |
| publisher assets carry the MIT grant. Attribution and the complete license travel | |
| with the converted bundle. Conversion uses `torch.load(weights_only=True)` and | |
| the standard safetensors writer, followed by exact tensor comparisons. | |
| The network is MONAI's 2D residual UNet: one input, 114 outputs, channels | |
| (64, 128, 256, 512, 1024), strides (2, 2, 2, 2), two residual units, instance | |
| normalization with epsilon 1e-5 and no affine parameters, LeakyReLU slope 0.01, | |
| and the upstream residual and transposed-convolution ordering. All 46 float32 | |
| checkpoint tensors retain their original names and values. The complete publisher | |
| label table is checked against the runtime: all 113 IDs, names, sides, regions and | |
| channel order must match. Background is channel/ID 0; anatomical IDs are not | |
| renumbered in the saved mask. | |
| Preprocessing follows `mm_segment.py`: apply NIfTI scaling, orient to RAS, | |
| resample to `[1, 1, -1]` mm (retain source slice spacing), normalize nonzero | |
| voxels, crop positive foreground with margin 20, then pad at the end to at least | |
| 256x256x1. The slice inferer uses 256x256 windows, batch size 1, Gaussian sigma | |
| scale 0.125 and 90% overlap. Inverse pad/crop, bilinear spacing restoration and | |
| orientation run on logits before argmax and anatomical remapping. Largest | |
| 6-connected components are selected after assembling all chunks. | |
| Chunking follows `mm_util.run_inference`: slice the last source storage axis, | |
| write each float32 chunk using the source NIfTI header, then preprocess each | |
| chunk independently. NiBabel rescales float32 data stored with an integer header; | |
| this can change zeros and therefore nonzero normalization. The native runtime | |
| reproduces that round trip using a private temporary directory. Skipping it | |
| initially caused 228 CT and 190 MRI final-voxel differences in these examples. | |
| The default is eight source slices; a chunk size at least the depth skips chunk | |
| serialization and processes the whole image. Comparisons require the same | |
| chunk size. | |
| Network operations run through MLX on Metal in float32. NIfTI I/O, geometry, | |
| Gaussian accumulation, argmax and connected components run on the host. An | |
| unavailable Metal device fails explicitly. Stored output is int16, with the | |
| original affine, distinct qform/sform matrices and codes, and unit metadata. | |
| Unknown spatial units are interpreted as mm while retaining the original unit | |
| field; explicitly different units are rejected. | |
| ## Real inputs and acceptance criteria | |
| The complete compact CT and MRI test volumes are from | |
| [TotalSegmentator at d89e47f](https://github.com/wasserth/TotalSegmentator/tree/d89e47f73d24f5fba732a715aeb6fdc0ae34526b/tests/reference_files). | |
| Its [official test commands](https://github.com/wasserth/TotalSegmentator/blob/d89e47f73d24f5fba732a715aeb6fdc0ae34526b/tests/tests.sh) | |
| supply the CT input to CT inference and the MRI input to `total_mr`; modality | |
| comes from that source definition. These are real | |
| images supplied as compact test examples, rather than newly synthesized images. | |
| Their NIfTI affines define 3 mm voxels; both have unspecified unit fields, qform | |
| code 0 and sform code 2. No header fields were altered for the experiment. | |
| | Input | Shape | Orientation | Foreground IDs present | | |
| | --- | --- | --- | --- | | |
| | `example_ct_sm.nii.gz` | 122x101x30 | RAS | 10 | | |
| | `example_mr_sm.nii.gz` | 117x91x20 | LPS | 10 | | |
| Acceptance was fixed before comparison: finite float32 network and restored | |
| logits within `atol=5e-4, rtol=1e-5`; exact final anatomical masks after component | |
| filtering; equal output shape, affine, spatial forms/codes and units; int16 | |
| storage. The same tensor windows are used for network comparisons. Restored-logit | |
| comparisons include native preprocessing, Gaussian aggregation and inverse | |
| geometry. CPU reduction rounding is reported separately. | |
| ## Results | |
| Qualification on 2026-11-13 used Python 3.13, MLX 0.32.4 and float32 on an Apple | |
| Silicon Mac. The independent reference used Python 3.11, | |
| PyTorch 2.4.1, MONAI 1.3.2, NumPy 1.24.4, NiBabel 5.2.1 and SciPy 1.11.4, | |
| with one CPU thread. Reference execution completed both on the Mac and on a | |
| DGX Spark GB10 using its CPU with the same pinned dependencies. Both examples | |
| used eight-slice chunks and 90% overlap. The table reports the largest error | |
| across these two independent reference executions. | |
| | Measurement | CT | MRI | | |
| | --- | --- | --- | | |
| | Maximum network-logit absolute error | 1.47e-4 | 1.36e-4 | | |
| | Maximum restored-logit absolute error | 1.15e-4 | 1.03e-4 | | |
| | Final mismatched voxels | 0 / 369,660 | 0 / 212,940 | | |
| | Dice for every foreground ID present | 1.0 | 1.0 | | |
| | Output grid, forms and units | Preserved | Preserved | | |
| CT preprocessing differed by at most 4.77e-7 from the reference after float32 | |
| normalization; MRI preprocessing matched exactly. Reference reader pixels were | |
| checked independently with pinned NiBabel. The complete public package runner | |
| also produced the exact reference masks. These measurements establish parity on | |
| two compact examples, without measuring manual-label accuracy or every one of | |
| the 113 anatomical structures. | |
| ## Reproduce | |
| Install the published runtime and download the public qualification tools at their | |
| reviewed revision. The reference uses Python 3.11; native execution uses Python | |
| 3.13 on Apple Silicon. The source distribution supplies the configuration parser | |
| for the reference environment, without installing an MLX runtime there. | |
| ```sh | |
| uv venv --python 3.13 | |
| source .venv/bin/activate | |
| uv pip install musclemap-mlx==0.1.1 | |
| hf download MedMLX/musclemap-mlx --revision 05fa11f1f13ded18d2efdb7a8e1dab77bd600234 --include 'qualification/*' --local-dir validation | |
| # Obtain the same published source used by the installed runtime. | |
| python - <<'PYCODE' | |
| import json, urllib.request | |
| metadata = json.load(urllib.request.urlopen("https://pypi.org/pypi/musclemap-mlx/0.1.1/json")) | |
| url = next(item["url"] for item in metadata["urls"] if item["packagetype"] == "sdist") | |
| urllib.request.urlretrieve(url, "musclemap_mlx-0.1.1.tar.gz") | |
| PYCODE | |
| tar -xf musclemap_mlx-0.1.1.tar.gz | |
| uv venv --python 3.11 oracle-env | |
| uv pip install --python oracle-env/bin/python -r validation/qualification/requirements.txt | |
| mkdir -p weights results | |
| curl -L https://zenodo.org/records/21929873/files/contrast_agnostic_wholebody_model.pth -o weights/contrast_agnostic_wholebody_model.pth | |
| curl -L https://zenodo.org/records/21929873/files/contrast_agnostic_wholebody_model.json -o weights/contrast_agnostic_wholebody_model.json | |
| curl -L https://zenodo.org/records/21929873/files/LICENSE -o weights/LICENSE | |
| curl -L https://raw.githubusercontent.com/wasserth/TotalSegmentator/d89e47f73d24f5fba732a715aeb6fdc0ae34526b/tests/reference_files/example_ct_sm.nii.gz -o ct.nii.gz | |
| curl -L https://raw.githubusercontent.com/wasserth/TotalSegmentator/d89e47f73d24f5fba732a715aeb6fdc0ae34526b/tests/reference_files/example_mr_sm.nii.gz -o mr.nii.gz | |
| PYTHONPATH=musclemap_mlx-0.1.1/src OMP_NUM_THREADS=1 OPENBLAS_NUM_THREADS=1 \ | |
| oracle-env/bin/python validation/qualification/make_reference_fixtures.py \ | |
| --assets weights --image ct.nii.gz --output results/ct-reference | |
| musclemap-mlx download --model-dir converted | |
| python validation/qualification/qualify_real.py \ | |
| --reference results/ct-reference --weights converted --output results/ct-parity.json | |
| ``` | |
| Repeat the last reference and comparison commands with `mr.nii.gz` and separate | |
| MRI result paths. The recorder can run on Linux; copy its result folder to the | |
| Mac for native comparison. `qualify_real.py` exits unsuccessfully for logit | |
| failures or any final mask mismatch and records per-chunk errors and per-label | |
| Dice. Generated images, weights, reference arrays and run output stay outside Git. | |