Download README.md from CaptureData/11_13_26_dataset: direct link, hf CLI and curl.
- Browser
- Download file 6.51 kB
-
https://huggingface.co/datasets/CaptureData/11_13_26_dataset/resolve/main/README.md
- Command line
-
hf download hf://datasets/CaptureData/11_13_26_dataset/README.md
-
curl -L -o README.md https://huggingface.co/datasets/CaptureData/11_13_26_dataset/resolve/main/README.md
6.51 kB
| pretty_name: "CAPTURE Dataset: GPDAS Prototype Data Acquisition - November 13, 2026" | |
| viewer: false | |
| tags: | |
| - video | |
| - timeseries | |
| - endoscopy | |
| - benchtop | |
| - multimodal | |
| # CAPTURE Dataset: GPDAS Prototype Data Acquisition | |
| **Collection Date:** November 13, 2026 | |
| **Environment:** Benchtop colonoscopy model | |
| **System:** GPDAS Instrumented Data Acquisition Prototype | |
| ## Overview | |
| This dataset contains five recording sessions collected using the GPDAS prototype, an instrumented colonoscopy testbed developed to capture synchronized video and operator actions. | |
| The recordings combine intraluminal video, external camera views, sensor measurements, and timing information to support research in computer vision, sensor integration, and machine learning. | |
| This collection represents an early stage of prototype development and is intended for research and development rather than clinical evaluation. | |
| [Browse All Dataset Files](https://huggingface.co/datasets/CaptureData/capture_11_13_26_dataset/tree/main) | |
| ## Recorded Data | |
| | Source | Description | | |
| |---|---| | |
| | **Ambu aBox** | Internal endoscope video showing the simulated intraluminal environment | | |
| | **Basler0** | High-resolution external camera recording supporting observation of instrument activity | | |
| | **Logitech Cameras (2)** | Supplementary external views of the instrument and procedure | | |
| | **Sensor and Timing Logs** | Recorded sensor channels, frame timestamps, and synchronization information | | |
| Sensor channels include demonstration measurements and should not be interpreted as fully calibrated operator-action data. | |
| ## Recording Sessions | |
| | Session | Description | | |
| |---|---| | |
| | **Session 1** | Initial recording test, stops at simulated CECUM (FWD INSERTION ONLY)) | | |
| | **Session 2** | Short setup and synchronization test | | |
| | **Session 3** | Completed 24-minute recording with two verified optical synchronization markers | | |
| | **Session 4** | Completed procedure, LED End sequence missing due to drive space| | |
| | **Session 5** | Partial recording with recovered webcam footage | | |
| **Session 3 is the recommended starting point** for researchers evaluating the available recordings and synchronization data. Its aBox video pairing was verified using both optical markers. Pairings for the remaining sessions are provisional. | |
| - [Browse Session 3 Files](https://huggingface.co/datasets/CaptureData/capture_11_13_26_dataset/tree/main/Session3_11_13_26) | |
| - [View Session 3 Basler MP4](https://huggingface.co/datasets/CaptureData/capture_11_13_26_dataset/blob/main/Encoding_Examples_Session3/Session3_Basler_H264.mp4) | |
| ## Accessing the Recordings | |
| Original camera recordings and associated metadata are preserved where available. Encoded MP4 examples are provided for easier inspection without requiring specialized raw-video processing tools. | |
| ### Encoding Examples | |
| - **Basler MP4:** Converted from the original raw Bayer image stream for conventional video playback. | |
| - **Logitech MP4:** Recovered and corrected webcam recordings, with available frame timing information preserved separately. | |
| - **Ambu aBox:** Internal endoscope recordings provided for comparison with external views. | |
| Encoded video is intended for viewing and preliminary analysis. Researchers performing synchronization or frame-level processing should use the original recordings and associated timing metadata. | |
| ### Working with Raw Video | |
| **Basler Camera** | |
| The Basler camera records uncompressed image frames in a raw Bayer format. Unlike an MP4, the raw file does not contain a conventional video header or playback timing information. | |
| | File | Purpose | | |
| |---|---| | |
| | `basler0.raw` | Original raw image frames | | |
| | `basler0_frames.csv` | Frame timing information | | |
| | Recording metadata (`.json`) | Image dimensions, pixel format, and acquisition parameters | | |
| The raw recording can be previewed or converted using FFmpeg, provided the correct image dimensions and pixel format are specified. | |
| **Example: Preview BayerRG8 video** | |
| ```bash | |
| ffplay -f rawvideo \ | |
| -pixel_format bayer_rggb8 \ | |
| -video_size WIDTHxHEIGHT \ | |
| -framerate FPS \ | |
| basler0.raw | |
| ``` | |
| **Example: Convert to H.264 MP4** | |
| ```bash | |
| ffmpeg -f rawvideo \ | |
| -pixel_format bayer_rggb8 \ | |
| -video_size WIDTHxHEIGHT \ | |
| -framerate FPS \ | |
| -i basler0.raw \ | |
| -vf format=yuv420p \ | |
| -c:v libx264 -crf 18 \ | |
| basler0_converted.mp4 | |
| ``` | |
| Replace `WIDTH`, `HEIGHT`, and `FPS` with the recording parameters. These examples assume tightly packed BayerRG8 frames without row padding; consult the recording metadata before processing. | |
| The frame rate supplied during conversion determines playback speed. **For synchronization and temporal analysis, use `basler0_frames.csv` rather than the timestamps generated by the converted MP4.** | |
| **Logitech Cameras** | |
| Webcam recordings are provided as corrected MP4 files. Each reconstructed clip begins at its own first available frame. | |
| - Sessions 2 and 3 use `camera*_frames.csv`. | |
| - Sessions 1, 4, and 5 use `camera*_frame_map.csv`. | |
| The timing files support approximate alignment between camera streams. Cross-camera exposure timing is not guaranteed to be frame-accurate. | |
| **Endoscope Video and Sensor Data** | |
| The internal aBox recordings can be examined alongside external camera views and the logged sensor measurements. | |
| Session 3 has a verified aBox video pairing using two optical synchronization markers. Other pairings remain provisional. | |
| ## Data Quality and Limitations | |
| This collection includes preliminary and partially recovered recordings. The following limitations apply: | |
| - Sessions 1, 4, and 5 are incomplete and include recovered webcam footage. | |
| - Partial Basler recordings may terminate with an incomplete image frame. | |
| - Cross-camera synchronization is approximate. | |
| - Frame timestamps do not necessarily represent exact exposure times. | |
| - Sensor channels include demonstration measurements and are not fully calibrated. | |
| - Calibrated insertion depth and clinical annotations are not included. | |
| Researchers should review individual session metadata before performing synchronized or frame-level analysis. | |
| ## Research Applications | |
| The dataset supports preliminary investigation of multimodal data acquisition, video synchronization, optical motion tracking, sensor-video alignment, and machine learning workflows. | |
| The recordings represent prototype research data and do not constitute a clinically validated or fully calibrated ground-truth dataset. | |
| ## License and Usage | |
| License information is pending. No public reuse license has been assigned. |