Datasets:
Download README.md from THULab/oil021_sample: direct link, hf CLI and curl.
- Browser
- Download file 10.4 kB
-
https://huggingface.co/datasets/THULab/oil021_sample/resolve/main/README.md
- Command line
-
hf download hf://datasets/THULab/oil021_sample/README.md
-
curl -L -o README.md https://huggingface.co/datasets/THULab/oil021_sample/resolve/main/README.md
license: cc-by-nc-4.0
task_categories:
- tabular-classification
- tabular-regression
- time-series-forecasting
language:
- en
tags:
- tsfile
- timeseries
- time-series
- synthetic
- oil-and-gas
- equipment-performance
- predictive-maintenance
- condition-monitoring
- rul-prediction
- vibration-analysis
- iso-10816
- api-617
- xpertsystems
- format:tsfile
pretty_name: OIL-021 — Synthetic Equipment Performance Dataset (Sample) (TsFile)
size_categories:
- 100K<n<1M
configs:
- config_name: default
data_files:
- split: alarm_trip_logs
path: alarm_trip_logs.tsfile
- split: compressor_performance
path: compressor_performance.tsfile
- split: efficiency_tracking
path: efficiency_tracking.tsfile
- split: equipment_failures
path: equipment_failures.tsfile
- split: equipment_labels
path: equipment_labels.tsfile
- split: equipment_master
path: equipment_master.tsfile
- split: heat_exchanger_performance
path: heat_exchanger_performance.tsfile
- split: lubrication_analysis
path: lubrication_analysis.tsfile
- split: maintenance_events
path: maintenance_events.tsfile
- split: pump_operations
path: pump_operations.tsfile
- split: thermal_monitoring
path: thermal_monitoring.tsfile
- split: vibration_signals
path: vibration_signals.tsfile
OIL-021 — Synthetic Equipment Performance Dataset (Sample) (TsFile)
Apache TsFile version of xpertsystems/oil021-sample.
Overview
A free, schema-identical preview of XpertSystems.ai's enterprise equipment performance dataset for predictive maintenance ML, vibration analysis, condition monitoring, RUL (remaining useful life) prediction, and equipment health scoring across rotating and static equipment. The sample covers 350 pieces of equipment across 8 equipment types, 6 plants, and 7 OEMs, with 179,149 rows linked across 12 tables via equipment_id.
- Tables: 12 TsFile table(s), 179,149 rows in total.
alarm_trip_logs: 2,347 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.020000 (UTC)compressor_performance: 6,240 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.051000 (UTC)efficiency_tracking: 42,000 rows, 2025-01-01 00:00:00 → 2025-04-30 00:00:00.349000 (UTC)equipment_failures: 47 rows, 2025-01-31 00:00:00 → 2025-12-12 00:00:00 (UTC)equipment_labels: 350 rows, 1970-01-01 00:00:00 → 1970-01-01 00:00:00.349000 (UTC)equipment_master: 350 rows, 2005-01-27 00:00:00 → 2024-12-02 00:00:00 (UTC)heat_exchanger_performance: 7,320 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.060000 (UTC)lubrication_analysis: 5,600 rows, 2025-01-01 00:00:00 → 2025-07-30 00:00:00.349000 (UTC)maintenance_events: 1,015 rows, 2025-01-02 00:00:00 → 2025-12-31 00:00:00 (UTC)pump_operations: 8,880 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.073000 (UTC)thermal_monitoring: 21,000 rows, 2025-01-01 00:00:00 → 2025-01-03 11:00:00.349000 (UTC)vibration_signals: 84,000 rows, 2025-01-01 00:00:00 → 2025-01-02 15:50:00.349000 (UTC)
Schema (TsFile structure)
alarm_trip_logs.tsfile
- Time (INT64, milliseconds) — the source
timestampcolumn. - TAG: none — the table is stored as a single device.
- FIELD (5):
alarm_id(string),equipment_id(string),alarm_code(string),trip_flag(int64),priority(string)
compressor_performance.tsfile
- Time (INT64, milliseconds) — the source
timestampcolumn. - TAG: none — the table is stored as a single device.
- FIELD (10):
compressor_id(string),equipment_id(string),suction_pressure_psi(double),discharge_pressure_psi(double),pressure_ratio(double),flow_rate_mmscfd(double),surge_margin_pct(double),compressor_efficiency_pct(double),power_kw(double),anti_surge_valve_pct(double)
efficiency_tracking.tsfile
- Time (INT64, milliseconds) — the source
timestampcolumn. - TAG: none — the table is stored as a single device.
- FIELD (5):
record_id(string),equipment_id(string),efficiency_pct(double),degradation_rate(double),runtime_hours(int64)
equipment_failures.tsfile
- Time (INT64, milliseconds) — the source
failure_datecolumn. - TAG: none — the table is stored as a single device.
- FIELD (6):
failure_id(string),equipment_id(string),failure_mode(string),root_cause(string),severity(string),repair_cost_usd(double)
equipment_labels.tsfile
- Time (INT64, milliseconds) — synthetic row index over the stable source order; this table has no clock column.
- TAG: none — the table is stored as a single device.
- FIELD (6):
label_id(string),equipment_id(string),health_score(double),failure_risk_class(string),rul_days(int64),maintenance_priority_score(double)
equipment_master.tsfile
- Time (INT64, milliseconds) — the source
commissioning_datecolumn. - TAG: none — the table is stored as a single device.
- FIELD (8):
equipment_id(string),equipment_type(string),plant_id(string),manufacturer(string),age_years(double),design_efficiency_pct(double),rated_power_kw(double),criticality(string)
heat_exchanger_performance.tsfile
- Time (INT64, milliseconds) — the source
timestampcolumn. - TAG: none — the table is stored as a single device.
- FIELD (10):
hx_id(string),equipment_id(string),inlet_temp_f(double),outlet_temp_f(double),cooling_water_temp_f(double),flow_rate_gpm(double),duty_mmbtu_hr(double),pressure_drop_psi(double),fouling_factor(double),efficiency_pct(double)
lubrication_analysis.tsfile
- Time (INT64, milliseconds) — the source
sample_datecolumn. - TAG: none — the table is stored as a single device.
- FIELD (8):
sample_id(string),equipment_id(string),viscosity_cst(double),water_ppm(double),iron_ppm(double),copper_ppm(double),oxidation_abs_cm(double),contamination_score(double)
maintenance_events.tsfile
- Time (INT64, milliseconds) — the source
event_datecolumn. - TAG: none — the table is stored as a single device.
- FIELD (6):
event_id(string),equipment_id(string),event_type(string),maintenance_class(string),downtime_hours(double),parts_replaced(string)
pump_operations.tsfile
- Time (INT64, milliseconds) — the source
timestampcolumn. - TAG: none — the table is stored as a single device.
- FIELD (8):
pump_id(string),equipment_id(string),flow_rate_bpd(double),head_ft(double),efficiency_pct(double),npsh_margin_ft(double),cavitation_index(double),motor_load_pct(double)
thermal_monitoring.tsfile
- Time (INT64, milliseconds) — the source
timestampcolumn. - TAG: none — the table is stored as a single device.
- FIELD (6):
thermal_id(string),equipment_id(string),bearing_temp_f(double),winding_temp_f(double),casing_temp_f(double),cooling_efficiency_pct(double)
vibration_signals.tsfile
- Time (INT64, milliseconds) — the source
timestampcolumn. - TAG: none — the table is stored as a single device.
- FIELD (7):
sensor_id(string),equipment_id(string),vibration_rms_mmsec(double),vibration_peak_mmsec(double),bearing_temp_f(double),axial_vibration_mmsec(double),radial_vibration_mmsec(double)
Conversion notes
- One TsFile per source CSV (12 tables); each table is stored as a single device, so the rig / well / tank / equipment / sensor identifiers stay ordinary FIELDs.
- Time = the table's own clock column as INT64 milliseconds (event timestamps, sample or inspection dates, and daily record dates). The clock columns used here are
commissioning_date,event_date,failure_date,sample_date,timestamp. - Tables with no clock column (
equipment_labels) use a synthetic row index over their stable source order as Time. - No column is dropped. Rows that share a timestamp are ordered by a 1 ms step in stable source order, so daily tables keep their exact calendar day.
Usage
Read this dataset with the Java SDK. It is written with the
zstdcompressor. The Apache TsFile Java SDK reads every compressor, but the Python SDK (pip install tsfile) implements onlyUNCOMPRESSED,SNAPPY,GZIPandLZ4; opening this file with it yields no rows.
Read a converted file with the Apache TsFile Java SDK (org.apache.tsfile:tsfile):
import org.apache.tsfile.file.metadata.IDeviceID;
import org.apache.tsfile.read.TsFileReader;
import org.apache.tsfile.read.TsFileSequenceReader;
import org.apache.tsfile.read.common.Path;
import org.apache.tsfile.read.expression.QueryExpression;
import org.apache.tsfile.read.query.dataset.QueryDataSet;
import org.apache.tsfile.write.schema.MeasurementSchema;
import java.util.ArrayList;
import java.util.List;
String path = "alarm_trip_logs.tsfile";
try (TsFileSequenceReader sequenceReader = new TsFileSequenceReader(path);
TsFileReader reader = new TsFileReader(sequenceReader)) {
// Devices are enumerated as IDeviceID objects. Tables with TAG columns
// have multi-segment device ids that cannot be rebuilt from their string
// form, so always use getAllDevices() rather than getAllDeviceIds().
for (IDeviceID device : sequenceReader.getAllDevices()) {
List<Path> paths = new ArrayList<>();
for (MeasurementSchema schema : reader.getMeasurement(device)) {
String name = schema.getMeasurementName();
if (name != null && !name.isEmpty() && !name.equalsIgnoreCase("Time")) {
paths.add(new Path(device, name, true));
}
}
QueryDataSet dataSet = reader.query(QueryExpression.create(paths, null));
while (dataSet.hasNext()) {
System.out.println(dataSet.next());
}
}
}
Source & license
- Original dataset:
xpertsystems/oil021-sample - Source card title: OIL-021 — Synthetic Equipment Performance Dataset (Sample)
- License: cc-by-nc-4.0 (as declared by the original dataset).