oil021_sample / README.md
wangdx25's picture
Add TsFile (converted from xpertsystems/oil021-sample)
62051b2 verified
|
Raw History Blame Contribute Delete
10.4 kB
metadata
license: cc-by-nc-4.0
task_categories:
  - tabular-classification
  - tabular-regression
  - time-series-forecasting
language:
  - en
tags:
  - tsfile
  - timeseries
  - time-series
  - synthetic
  - oil-and-gas
  - equipment-performance
  - predictive-maintenance
  - condition-monitoring
  - rul-prediction
  - vibration-analysis
  - iso-10816
  - api-617
  - xpertsystems
  - format:tsfile
pretty_name: OIL-021 — Synthetic Equipment Performance Dataset (Sample) (TsFile)
size_categories:
  - 100K<n<1M
configs:
  - config_name: default
    data_files:
      - split: alarm_trip_logs
        path: alarm_trip_logs.tsfile
      - split: compressor_performance
        path: compressor_performance.tsfile
      - split: efficiency_tracking
        path: efficiency_tracking.tsfile
      - split: equipment_failures
        path: equipment_failures.tsfile
      - split: equipment_labels
        path: equipment_labels.tsfile
      - split: equipment_master
        path: equipment_master.tsfile
      - split: heat_exchanger_performance
        path: heat_exchanger_performance.tsfile
      - split: lubrication_analysis
        path: lubrication_analysis.tsfile
      - split: maintenance_events
        path: maintenance_events.tsfile
      - split: pump_operations
        path: pump_operations.tsfile
      - split: thermal_monitoring
        path: thermal_monitoring.tsfile
      - split: vibration_signals
        path: vibration_signals.tsfile

OIL-021 — Synthetic Equipment Performance Dataset (Sample) (TsFile)

Apache TsFile version of xpertsystems/oil021-sample.

Overview

A free, schema-identical preview of XpertSystems.ai's enterprise equipment performance dataset for predictive maintenance ML, vibration analysis, condition monitoring, RUL (remaining useful life) prediction, and equipment health scoring across rotating and static equipment. The sample covers 350 pieces of equipment across 8 equipment types, 6 plants, and 7 OEMs, with 179,149 rows linked across 12 tables via equipment_id.

  • Tables: 12 TsFile table(s), 179,149 rows in total.
    • alarm_trip_logs: 2,347 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.020000 (UTC)
    • compressor_performance: 6,240 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.051000 (UTC)
    • efficiency_tracking: 42,000 rows, 2025-01-01 00:00:00 → 2025-04-30 00:00:00.349000 (UTC)
    • equipment_failures: 47 rows, 2025-01-31 00:00:00 → 2025-12-12 00:00:00 (UTC)
    • equipment_labels: 350 rows, 1970-01-01 00:00:00 → 1970-01-01 00:00:00.349000 (UTC)
    • equipment_master: 350 rows, 2005-01-27 00:00:00 → 2024-12-02 00:00:00 (UTC)
    • heat_exchanger_performance: 7,320 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.060000 (UTC)
    • lubrication_analysis: 5,600 rows, 2025-01-01 00:00:00 → 2025-07-30 00:00:00.349000 (UTC)
    • maintenance_events: 1,015 rows, 2025-01-02 00:00:00 → 2025-12-31 00:00:00 (UTC)
    • pump_operations: 8,880 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.073000 (UTC)
    • thermal_monitoring: 21,000 rows, 2025-01-01 00:00:00 → 2025-01-03 11:00:00.349000 (UTC)
    • vibration_signals: 84,000 rows, 2025-01-01 00:00:00 → 2025-01-02 15:50:00.349000 (UTC)

Schema (TsFile structure)

alarm_trip_logs.tsfile

  • Time (INT64, milliseconds) — the source timestamp column.
  • TAG: none — the table is stored as a single device.
  • FIELD (5): alarm_id (string), equipment_id (string), alarm_code (string), trip_flag (int64), priority (string)

compressor_performance.tsfile

  • Time (INT64, milliseconds) — the source timestamp column.
  • TAG: none — the table is stored as a single device.
  • FIELD (10): compressor_id (string), equipment_id (string), suction_pressure_psi (double), discharge_pressure_psi (double), pressure_ratio (double), flow_rate_mmscfd (double), surge_margin_pct (double), compressor_efficiency_pct (double), power_kw (double), anti_surge_valve_pct (double)

efficiency_tracking.tsfile

  • Time (INT64, milliseconds) — the source timestamp column.
  • TAG: none — the table is stored as a single device.
  • FIELD (5): record_id (string), equipment_id (string), efficiency_pct (double), degradation_rate (double), runtime_hours (int64)

equipment_failures.tsfile

  • Time (INT64, milliseconds) — the source failure_date column.
  • TAG: none — the table is stored as a single device.
  • FIELD (6): failure_id (string), equipment_id (string), failure_mode (string), root_cause (string), severity (string), repair_cost_usd (double)

equipment_labels.tsfile

  • Time (INT64, milliseconds) — synthetic row index over the stable source order; this table has no clock column.
  • TAG: none — the table is stored as a single device.
  • FIELD (6): label_id (string), equipment_id (string), health_score (double), failure_risk_class (string), rul_days (int64), maintenance_priority_score (double)

equipment_master.tsfile

  • Time (INT64, milliseconds) — the source commissioning_date column.
  • TAG: none — the table is stored as a single device.
  • FIELD (8): equipment_id (string), equipment_type (string), plant_id (string), manufacturer (string), age_years (double), design_efficiency_pct (double), rated_power_kw (double), criticality (string)

heat_exchanger_performance.tsfile

  • Time (INT64, milliseconds) — the source timestamp column.
  • TAG: none — the table is stored as a single device.
  • FIELD (10): hx_id (string), equipment_id (string), inlet_temp_f (double), outlet_temp_f (double), cooling_water_temp_f (double), flow_rate_gpm (double), duty_mmbtu_hr (double), pressure_drop_psi (double), fouling_factor (double), efficiency_pct (double)

lubrication_analysis.tsfile

  • Time (INT64, milliseconds) — the source sample_date column.
  • TAG: none — the table is stored as a single device.
  • FIELD (8): sample_id (string), equipment_id (string), viscosity_cst (double), water_ppm (double), iron_ppm (double), copper_ppm (double), oxidation_abs_cm (double), contamination_score (double)

maintenance_events.tsfile

  • Time (INT64, milliseconds) — the source event_date column.
  • TAG: none — the table is stored as a single device.
  • FIELD (6): event_id (string), equipment_id (string), event_type (string), maintenance_class (string), downtime_hours (double), parts_replaced (string)

pump_operations.tsfile

  • Time (INT64, milliseconds) — the source timestamp column.
  • TAG: none — the table is stored as a single device.
  • FIELD (8): pump_id (string), equipment_id (string), flow_rate_bpd (double), head_ft (double), efficiency_pct (double), npsh_margin_ft (double), cavitation_index (double), motor_load_pct (double)

thermal_monitoring.tsfile

  • Time (INT64, milliseconds) — the source timestamp column.
  • TAG: none — the table is stored as a single device.
  • FIELD (6): thermal_id (string), equipment_id (string), bearing_temp_f (double), winding_temp_f (double), casing_temp_f (double), cooling_efficiency_pct (double)

vibration_signals.tsfile

  • Time (INT64, milliseconds) — the source timestamp column.
  • TAG: none — the table is stored as a single device.
  • FIELD (7): sensor_id (string), equipment_id (string), vibration_rms_mmsec (double), vibration_peak_mmsec (double), bearing_temp_f (double), axial_vibration_mmsec (double), radial_vibration_mmsec (double)

Conversion notes

  • One TsFile per source CSV (12 tables); each table is stored as a single device, so the rig / well / tank / equipment / sensor identifiers stay ordinary FIELDs.
  • Time = the table's own clock column as INT64 milliseconds (event timestamps, sample or inspection dates, and daily record dates). The clock columns used here are commissioning_date, event_date, failure_date, sample_date, timestamp.
  • Tables with no clock column (equipment_labels) use a synthetic row index over their stable source order as Time.
  • No column is dropped. Rows that share a timestamp are ordered by a 1 ms step in stable source order, so daily tables keep their exact calendar day.

Usage

Read this dataset with the Java SDK. It is written with the zstd compressor. The Apache TsFile Java SDK reads every compressor, but the Python SDK (pip install tsfile) implements only UNCOMPRESSED, SNAPPY, GZIP and LZ4; opening this file with it yields no rows.

Read a converted file with the Apache TsFile Java SDK (org.apache.tsfile:tsfile):

import org.apache.tsfile.file.metadata.IDeviceID;
import org.apache.tsfile.read.TsFileReader;
import org.apache.tsfile.read.TsFileSequenceReader;
import org.apache.tsfile.read.common.Path;
import org.apache.tsfile.read.expression.QueryExpression;
import org.apache.tsfile.read.query.dataset.QueryDataSet;
import org.apache.tsfile.write.schema.MeasurementSchema;

import java.util.ArrayList;
import java.util.List;

String path = "alarm_trip_logs.tsfile";
try (TsFileSequenceReader sequenceReader = new TsFileSequenceReader(path);
     TsFileReader reader = new TsFileReader(sequenceReader)) {
    // Devices are enumerated as IDeviceID objects. Tables with TAG columns
    // have multi-segment device ids that cannot be rebuilt from their string
    // form, so always use getAllDevices() rather than getAllDeviceIds().
    for (IDeviceID device : sequenceReader.getAllDevices()) {
        List<Path> paths = new ArrayList<>();
        for (MeasurementSchema schema : reader.getMeasurement(device)) {
            String name = schema.getMeasurementName();
            if (name != null && !name.isEmpty() && !name.equalsIgnoreCase("Time")) {
                paths.add(new Path(device, name, true));
            }
        }
        QueryDataSet dataSet = reader.query(QueryExpression.create(paths, null));
        while (dataSet.hasNext()) {
            System.out.println(dataSet.next());
        }
    }
}

Source & license

  • Original dataset: xpertsystems/oil021-sample
  • Source card title: OIL-021 — Synthetic Equipment Performance Dataset (Sample)
  • License: cc-by-nc-4.0 (as declared by the original dataset).