Datasets:
|
Download README.md from THULab/oil021_sample: direct link, hf CLI and curl.
- Browser
- Download file 10.4 kB
-
https://huggingface.co/datasets/THULab/oil021_sample/resolve/main/README.md
- Command line
-
hf download hf://datasets/THULab/oil021_sample/README.md
-
curl -L -o README.md https://huggingface.co/datasets/THULab/oil021_sample/resolve/main/README.md
10.4 kB
| license: cc-by-nc-4.0 | |
| task_categories: | |
| - tabular-classification | |
| - tabular-regression | |
| - time-series-forecasting | |
| language: | |
| - en | |
| tags: | |
| - tsfile | |
| - timeseries | |
| - time-series | |
| - synthetic | |
| - oil-and-gas | |
| - equipment-performance | |
| - predictive-maintenance | |
| - condition-monitoring | |
| - rul-prediction | |
| - vibration-analysis | |
| - iso-10816 | |
| - api-617 | |
| - xpertsystems | |
| - format:tsfile | |
| pretty_name: OIL-021 — Synthetic Equipment Performance Dataset (Sample) (TsFile) | |
| size_categories: | |
| - 100K<n<1M | |
| configs: | |
| - config_name: default | |
| data_files: | |
| - split: alarm_trip_logs | |
| path: alarm_trip_logs.tsfile | |
| - split: compressor_performance | |
| path: compressor_performance.tsfile | |
| - split: efficiency_tracking | |
| path: efficiency_tracking.tsfile | |
| - split: equipment_failures | |
| path: equipment_failures.tsfile | |
| - split: equipment_labels | |
| path: equipment_labels.tsfile | |
| - split: equipment_master | |
| path: equipment_master.tsfile | |
| - split: heat_exchanger_performance | |
| path: heat_exchanger_performance.tsfile | |
| - split: lubrication_analysis | |
| path: lubrication_analysis.tsfile | |
| - split: maintenance_events | |
| path: maintenance_events.tsfile | |
| - split: pump_operations | |
| path: pump_operations.tsfile | |
| - split: thermal_monitoring | |
| path: thermal_monitoring.tsfile | |
| - split: vibration_signals | |
| path: vibration_signals.tsfile | |
| # OIL-021 — Synthetic Equipment Performance Dataset (Sample) (TsFile) | |
| Apache TsFile version of [`xpertsystems/oil021-sample`](https://huggingface.co/datasets/xpertsystems/oil021-sample). | |
| ## Overview | |
| A free, schema-identical preview of XpertSystems.ai's enterprise equipment performance dataset for **predictive maintenance ML, vibration analysis, condition monitoring, RUL (remaining useful life) prediction, and equipment health scoring** across rotating and static equipment. The sample covers **350 pieces of equipment** across **8 equipment types**, **6 plants**, and **7 OEMs**, with **179,149 rows** linked across **12 tables** via `equipment_id`. | |
| - **Tables:** 12 TsFile table(s), 179,149 rows in total. | |
| - `alarm_trip_logs`: 2,347 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.020000 (UTC) | |
| - `compressor_performance`: 6,240 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.051000 (UTC) | |
| - `efficiency_tracking`: 42,000 rows, 2025-01-01 00:00:00 → 2025-04-30 00:00:00.349000 (UTC) | |
| - `equipment_failures`: 47 rows, 2025-01-31 00:00:00 → 2025-12-12 00:00:00 (UTC) | |
| - `equipment_labels`: 350 rows, 1970-01-01 00:00:00 → 1970-01-01 00:00:00.349000 (UTC) | |
| - `equipment_master`: 350 rows, 2005-01-27 00:00:00 → 2024-12-02 00:00:00 (UTC) | |
| - `heat_exchanger_performance`: 7,320 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.060000 (UTC) | |
| - `lubrication_analysis`: 5,600 rows, 2025-01-01 00:00:00 → 2025-07-30 00:00:00.349000 (UTC) | |
| - `maintenance_events`: 1,015 rows, 2025-01-02 00:00:00 → 2025-12-31 00:00:00 (UTC) | |
| - `pump_operations`: 8,880 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.073000 (UTC) | |
| - `thermal_monitoring`: 21,000 rows, 2025-01-01 00:00:00 → 2025-01-03 11:00:00.349000 (UTC) | |
| - `vibration_signals`: 84,000 rows, 2025-01-01 00:00:00 → 2025-01-02 15:50:00.349000 (UTC) | |
| ## Schema (TsFile structure) | |
| ### `alarm_trip_logs.tsfile` | |
| - **Time** (INT64, milliseconds) — the source `timestamp` column. | |
| - **TAG**: none — the table is stored as a single device. | |
| - **FIELD** (5): `alarm_id` (string), `equipment_id` (string), `alarm_code` (string), `trip_flag` (int64), `priority` (string) | |
| ### `compressor_performance.tsfile` | |
| - **Time** (INT64, milliseconds) — the source `timestamp` column. | |
| - **TAG**: none — the table is stored as a single device. | |
| - **FIELD** (10): `compressor_id` (string), `equipment_id` (string), `suction_pressure_psi` (double), `discharge_pressure_psi` (double), `pressure_ratio` (double), `flow_rate_mmscfd` (double), `surge_margin_pct` (double), `compressor_efficiency_pct` (double), `power_kw` (double), `anti_surge_valve_pct` (double) | |
| ### `efficiency_tracking.tsfile` | |
| - **Time** (INT64, milliseconds) — the source `timestamp` column. | |
| - **TAG**: none — the table is stored as a single device. | |
| - **FIELD** (5): `record_id` (string), `equipment_id` (string), `efficiency_pct` (double), `degradation_rate` (double), `runtime_hours` (int64) | |
| ### `equipment_failures.tsfile` | |
| - **Time** (INT64, milliseconds) — the source `failure_date` column. | |
| - **TAG**: none — the table is stored as a single device. | |
| - **FIELD** (6): `failure_id` (string), `equipment_id` (string), `failure_mode` (string), `root_cause` (string), `severity` (string), `repair_cost_usd` (double) | |
| ### `equipment_labels.tsfile` | |
| - **Time** (INT64, milliseconds) — synthetic row index over the stable source order; this table has no clock column. | |
| - **TAG**: none — the table is stored as a single device. | |
| - **FIELD** (6): `label_id` (string), `equipment_id` (string), `health_score` (double), `failure_risk_class` (string), `rul_days` (int64), `maintenance_priority_score` (double) | |
| ### `equipment_master.tsfile` | |
| - **Time** (INT64, milliseconds) — the source `commissioning_date` column. | |
| - **TAG**: none — the table is stored as a single device. | |
| - **FIELD** (8): `equipment_id` (string), `equipment_type` (string), `plant_id` (string), `manufacturer` (string), `age_years` (double), `design_efficiency_pct` (double), `rated_power_kw` (double), `criticality` (string) | |
| ### `heat_exchanger_performance.tsfile` | |
| - **Time** (INT64, milliseconds) — the source `timestamp` column. | |
| - **TAG**: none — the table is stored as a single device. | |
| - **FIELD** (10): `hx_id` (string), `equipment_id` (string), `inlet_temp_f` (double), `outlet_temp_f` (double), `cooling_water_temp_f` (double), `flow_rate_gpm` (double), `duty_mmbtu_hr` (double), `pressure_drop_psi` (double), `fouling_factor` (double), `efficiency_pct` (double) | |
| ### `lubrication_analysis.tsfile` | |
| - **Time** (INT64, milliseconds) — the source `sample_date` column. | |
| - **TAG**: none — the table is stored as a single device. | |
| - **FIELD** (8): `sample_id` (string), `equipment_id` (string), `viscosity_cst` (double), `water_ppm` (double), `iron_ppm` (double), `copper_ppm` (double), `oxidation_abs_cm` (double), `contamination_score` (double) | |
| ### `maintenance_events.tsfile` | |
| - **Time** (INT64, milliseconds) — the source `event_date` column. | |
| - **TAG**: none — the table is stored as a single device. | |
| - **FIELD** (6): `event_id` (string), `equipment_id` (string), `event_type` (string), `maintenance_class` (string), `downtime_hours` (double), `parts_replaced` (string) | |
| ### `pump_operations.tsfile` | |
| - **Time** (INT64, milliseconds) — the source `timestamp` column. | |
| - **TAG**: none — the table is stored as a single device. | |
| - **FIELD** (8): `pump_id` (string), `equipment_id` (string), `flow_rate_bpd` (double), `head_ft` (double), `efficiency_pct` (double), `npsh_margin_ft` (double), `cavitation_index` (double), `motor_load_pct` (double) | |
| ### `thermal_monitoring.tsfile` | |
| - **Time** (INT64, milliseconds) — the source `timestamp` column. | |
| - **TAG**: none — the table is stored as a single device. | |
| - **FIELD** (6): `thermal_id` (string), `equipment_id` (string), `bearing_temp_f` (double), `winding_temp_f` (double), `casing_temp_f` (double), `cooling_efficiency_pct` (double) | |
| ### `vibration_signals.tsfile` | |
| - **Time** (INT64, milliseconds) — the source `timestamp` column. | |
| - **TAG**: none — the table is stored as a single device. | |
| - **FIELD** (7): `sensor_id` (string), `equipment_id` (string), `vibration_rms_mmsec` (double), `vibration_peak_mmsec` (double), `bearing_temp_f` (double), `axial_vibration_mmsec` (double), `radial_vibration_mmsec` (double) | |
| ## Conversion notes | |
| - One TsFile per source CSV (12 tables); each table is stored as a single device, so the rig / well / tank / equipment / sensor identifiers stay ordinary FIELDs. | |
| - Time = the table's own clock column as INT64 milliseconds (event timestamps, sample or inspection dates, and daily record dates). The clock columns used here are `commissioning_date`, `event_date`, `failure_date`, `sample_date`, `timestamp`. | |
| - Tables with no clock column (`equipment_labels`) use a synthetic row index over their stable source order as Time. | |
| - No column is dropped. Rows that share a timestamp are ordered by a 1 ms step in stable source order, so daily tables keep their exact calendar day. | |
| ## Usage | |
| > **Read this dataset with the Java SDK.** It is written with the `zstd` compressor. The Apache TsFile Java SDK reads every compressor, but the Python SDK (`pip install tsfile`) implements only `UNCOMPRESSED`, `SNAPPY`, `GZIP` and `LZ4`; opening this file with it yields no rows. | |
| Read a converted file with the Apache TsFile Java SDK (`org.apache.tsfile:tsfile`): | |
| ```java | |
| import org.apache.tsfile.file.metadata.IDeviceID; | |
| import org.apache.tsfile.read.TsFileReader; | |
| import org.apache.tsfile.read.TsFileSequenceReader; | |
| import org.apache.tsfile.read.common.Path; | |
| import org.apache.tsfile.read.expression.QueryExpression; | |
| import org.apache.tsfile.read.query.dataset.QueryDataSet; | |
| import org.apache.tsfile.write.schema.MeasurementSchema; | |
| import java.util.ArrayList; | |
| import java.util.List; | |
| String path = "alarm_trip_logs.tsfile"; | |
| try (TsFileSequenceReader sequenceReader = new TsFileSequenceReader(path); | |
| TsFileReader reader = new TsFileReader(sequenceReader)) { | |
| // Devices are enumerated as IDeviceID objects. Tables with TAG columns | |
| // have multi-segment device ids that cannot be rebuilt from their string | |
| // form, so always use getAllDevices() rather than getAllDeviceIds(). | |
| for (IDeviceID device : sequenceReader.getAllDevices()) { | |
| List<Path> paths = new ArrayList<>(); | |
| for (MeasurementSchema schema : reader.getMeasurement(device)) { | |
| String name = schema.getMeasurementName(); | |
| if (name != null && !name.isEmpty() && !name.equalsIgnoreCase("Time")) { | |
| paths.add(new Path(device, name, true)); | |
| } | |
| } | |
| QueryDataSet dataSet = reader.query(QueryExpression.create(paths, null)); | |
| while (dataSet.hasNext()) { | |
| System.out.println(dataSet.next()); | |
| } | |
| } | |
| } | |
| ``` | |
| ## Source & license | |
| - Original dataset: [`xpertsystems/oil021-sample`](https://huggingface.co/datasets/xpertsystems/oil021-sample) | |
| - Source card title: OIL-021 — Synthetic Equipment Performance Dataset (Sample) | |
| - License: cc-by-nc-4.0 (as declared by the original dataset). | |