oil021_sample / README.md
wangdx25's picture
Add TsFile (converted from xpertsystems/oil021-sample)
62051b2 verified
|
Raw History Blame Contribute Delete
10.4 kB
---
license: cc-by-nc-4.0
task_categories:
- tabular-classification
- tabular-regression
- time-series-forecasting
language:
- en
tags:
- tsfile
- timeseries
- time-series
- synthetic
- oil-and-gas
- equipment-performance
- predictive-maintenance
- condition-monitoring
- rul-prediction
- vibration-analysis
- iso-10816
- api-617
- xpertsystems
- format:tsfile
pretty_name: OIL-021 — Synthetic Equipment Performance Dataset (Sample) (TsFile)
size_categories:
- 100K<n<1M
configs:
- config_name: default
data_files:
- split: alarm_trip_logs
path: alarm_trip_logs.tsfile
- split: compressor_performance
path: compressor_performance.tsfile
- split: efficiency_tracking
path: efficiency_tracking.tsfile
- split: equipment_failures
path: equipment_failures.tsfile
- split: equipment_labels
path: equipment_labels.tsfile
- split: equipment_master
path: equipment_master.tsfile
- split: heat_exchanger_performance
path: heat_exchanger_performance.tsfile
- split: lubrication_analysis
path: lubrication_analysis.tsfile
- split: maintenance_events
path: maintenance_events.tsfile
- split: pump_operations
path: pump_operations.tsfile
- split: thermal_monitoring
path: thermal_monitoring.tsfile
- split: vibration_signals
path: vibration_signals.tsfile
---
# OIL-021 — Synthetic Equipment Performance Dataset (Sample) (TsFile)
Apache TsFile version of [`xpertsystems/oil021-sample`](https://huggingface.co/datasets/xpertsystems/oil021-sample).
## Overview
A free, schema-identical preview of XpertSystems.ai's enterprise equipment performance dataset for **predictive maintenance ML, vibration analysis, condition monitoring, RUL (remaining useful life) prediction, and equipment health scoring** across rotating and static equipment. The sample covers **350 pieces of equipment** across **8 equipment types**, **6 plants**, and **7 OEMs**, with **179,149 rows** linked across **12 tables** via `equipment_id`.
- **Tables:** 12 TsFile table(s), 179,149 rows in total.
- `alarm_trip_logs`: 2,347 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.020000 (UTC)
- `compressor_performance`: 6,240 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.051000 (UTC)
- `efficiency_tracking`: 42,000 rows, 2025-01-01 00:00:00 → 2025-04-30 00:00:00.349000 (UTC)
- `equipment_failures`: 47 rows, 2025-01-31 00:00:00 → 2025-12-12 00:00:00 (UTC)
- `equipment_labels`: 350 rows, 1970-01-01 00:00:00 → 1970-01-01 00:00:00.349000 (UTC)
- `equipment_master`: 350 rows, 2005-01-27 00:00:00 → 2024-12-02 00:00:00 (UTC)
- `heat_exchanger_performance`: 7,320 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.060000 (UTC)
- `lubrication_analysis`: 5,600 rows, 2025-01-01 00:00:00 → 2025-07-30 00:00:00.349000 (UTC)
- `maintenance_events`: 1,015 rows, 2025-01-02 00:00:00 → 2025-12-31 00:00:00 (UTC)
- `pump_operations`: 8,880 rows, 2025-01-01 00:00:00 → 2025-01-05 23:00:00.073000 (UTC)
- `thermal_monitoring`: 21,000 rows, 2025-01-01 00:00:00 → 2025-01-03 11:00:00.349000 (UTC)
- `vibration_signals`: 84,000 rows, 2025-01-01 00:00:00 → 2025-01-02 15:50:00.349000 (UTC)
## Schema (TsFile structure)
### `alarm_trip_logs.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (5): `alarm_id` (string), `equipment_id` (string), `alarm_code` (string), `trip_flag` (int64), `priority` (string)
### `compressor_performance.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (10): `compressor_id` (string), `equipment_id` (string), `suction_pressure_psi` (double), `discharge_pressure_psi` (double), `pressure_ratio` (double), `flow_rate_mmscfd` (double), `surge_margin_pct` (double), `compressor_efficiency_pct` (double), `power_kw` (double), `anti_surge_valve_pct` (double)
### `efficiency_tracking.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (5): `record_id` (string), `equipment_id` (string), `efficiency_pct` (double), `degradation_rate` (double), `runtime_hours` (int64)
### `equipment_failures.tsfile`
- **Time** (INT64, milliseconds) — the source `failure_date` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (6): `failure_id` (string), `equipment_id` (string), `failure_mode` (string), `root_cause` (string), `severity` (string), `repair_cost_usd` (double)
### `equipment_labels.tsfile`
- **Time** (INT64, milliseconds) — synthetic row index over the stable source order; this table has no clock column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (6): `label_id` (string), `equipment_id` (string), `health_score` (double), `failure_risk_class` (string), `rul_days` (int64), `maintenance_priority_score` (double)
### `equipment_master.tsfile`
- **Time** (INT64, milliseconds) — the source `commissioning_date` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (8): `equipment_id` (string), `equipment_type` (string), `plant_id` (string), `manufacturer` (string), `age_years` (double), `design_efficiency_pct` (double), `rated_power_kw` (double), `criticality` (string)
### `heat_exchanger_performance.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (10): `hx_id` (string), `equipment_id` (string), `inlet_temp_f` (double), `outlet_temp_f` (double), `cooling_water_temp_f` (double), `flow_rate_gpm` (double), `duty_mmbtu_hr` (double), `pressure_drop_psi` (double), `fouling_factor` (double), `efficiency_pct` (double)
### `lubrication_analysis.tsfile`
- **Time** (INT64, milliseconds) — the source `sample_date` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (8): `sample_id` (string), `equipment_id` (string), `viscosity_cst` (double), `water_ppm` (double), `iron_ppm` (double), `copper_ppm` (double), `oxidation_abs_cm` (double), `contamination_score` (double)
### `maintenance_events.tsfile`
- **Time** (INT64, milliseconds) — the source `event_date` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (6): `event_id` (string), `equipment_id` (string), `event_type` (string), `maintenance_class` (string), `downtime_hours` (double), `parts_replaced` (string)
### `pump_operations.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (8): `pump_id` (string), `equipment_id` (string), `flow_rate_bpd` (double), `head_ft` (double), `efficiency_pct` (double), `npsh_margin_ft` (double), `cavitation_index` (double), `motor_load_pct` (double)
### `thermal_monitoring.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (6): `thermal_id` (string), `equipment_id` (string), `bearing_temp_f` (double), `winding_temp_f` (double), `casing_temp_f` (double), `cooling_efficiency_pct` (double)
### `vibration_signals.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (7): `sensor_id` (string), `equipment_id` (string), `vibration_rms_mmsec` (double), `vibration_peak_mmsec` (double), `bearing_temp_f` (double), `axial_vibration_mmsec` (double), `radial_vibration_mmsec` (double)
## Conversion notes
- One TsFile per source CSV (12 tables); each table is stored as a single device, so the rig / well / tank / equipment / sensor identifiers stay ordinary FIELDs.
- Time = the table's own clock column as INT64 milliseconds (event timestamps, sample or inspection dates, and daily record dates). The clock columns used here are `commissioning_date`, `event_date`, `failure_date`, `sample_date`, `timestamp`.
- Tables with no clock column (`equipment_labels`) use a synthetic row index over their stable source order as Time.
- No column is dropped. Rows that share a timestamp are ordered by a 1 ms step in stable source order, so daily tables keep their exact calendar day.
## Usage
> **Read this dataset with the Java SDK.** It is written with the `zstd` compressor. The Apache TsFile Java SDK reads every compressor, but the Python SDK (`pip install tsfile`) implements only `UNCOMPRESSED`, `SNAPPY`, `GZIP` and `LZ4`; opening this file with it yields no rows.
Read a converted file with the Apache TsFile Java SDK (`org.apache.tsfile:tsfile`):
```java
import org.apache.tsfile.file.metadata.IDeviceID;
import org.apache.tsfile.read.TsFileReader;
import org.apache.tsfile.read.TsFileSequenceReader;
import org.apache.tsfile.read.common.Path;
import org.apache.tsfile.read.expression.QueryExpression;
import org.apache.tsfile.read.query.dataset.QueryDataSet;
import org.apache.tsfile.write.schema.MeasurementSchema;
import java.util.ArrayList;
import java.util.List;
String path = "alarm_trip_logs.tsfile";
try (TsFileSequenceReader sequenceReader = new TsFileSequenceReader(path);
TsFileReader reader = new TsFileReader(sequenceReader)) {
// Devices are enumerated as IDeviceID objects. Tables with TAG columns
// have multi-segment device ids that cannot be rebuilt from their string
// form, so always use getAllDevices() rather than getAllDeviceIds().
for (IDeviceID device : sequenceReader.getAllDevices()) {
List<Path> paths = new ArrayList<>();
for (MeasurementSchema schema : reader.getMeasurement(device)) {
String name = schema.getMeasurementName();
if (name != null && !name.isEmpty() && !name.equalsIgnoreCase("Time")) {
paths.add(new Path(device, name, true));
}
}
QueryDataSet dataSet = reader.query(QueryExpression.create(paths, null));
while (dataSet.hasNext()) {
System.out.println(dataSet.next());
}
}
}
```
## Source & license
- Original dataset: [`xpertsystems/oil021-sample`](https://huggingface.co/datasets/xpertsystems/oil021-sample)
- Source card title: OIL-021 — Synthetic Equipment Performance Dataset (Sample)
- License: cc-by-nc-4.0 (as declared by the original dataset).