oil024_sample / README.md
wangdx25's picture
Add TsFile (converted from xpertsystems/oil024-sample)
6928500 verified
|
Raw History Blame Contribute Delete
10.9 kB
---
license: cc-by-nc-4.0
task_categories:
- tabular-classification
- tabular-regression
- time-series-forecasting
language:
- en
tags:
- tsfile
- timeseries
- time-series
- synthetic
- oil-and-gas
- midstream
- pipeline
- hydraulics
- darcy-weisbach
- swamee-jain
- leak-detection
- scada
- flow-assurance
- xpertsystems
- format:tsfile
pretty_name: OIL-024 — Synthetic Pipeline Flow Dataset (Sample) (TsFile)
size_categories:
- 100K<n<1M
configs:
- config_name: default
data_files:
- split: compressor_operations
path: compressor_operations.tsfile
- split: corrosion_erosion
path: corrosion_erosion.tsfile
- split: flow_assurance
path: flow_assurance.tsfile
- split: hydraulic_profiles
path: hydraulic_profiles.tsfile
- split: leak_detection
path: leak_detection.tsfile
- split: optimization_labels
path: optimization_labels.tsfile
- split: pipeline_master
path: pipeline_master.tsfile
- split: pump_station_operations
path: pump_station_operations.tsfile
- split: scada_telemetry
path: scada_telemetry.tsfile
- split: thermal_profiles
path: thermal_profiles.tsfile
- split: transient_events
path: transient_events.tsfile
- split: valve_operations
path: valve_operations.tsfile
---
# OIL-024 — Synthetic Pipeline Flow Dataset (Sample) (TsFile)
Apache TsFile version of [`xpertsystems/oil024-sample`](https://huggingface.co/datasets/xpertsystems/oil024-sample).
## Overview
A free, schema-identical preview of XpertSystems.ai's enterprise pipeline flow dataset for **hydraulic modeling, leak detection, flow assurance, SCADA telemetry analytics, pump/compressor optimization, and pipeline reliability ML**. The sample covers **55 pipelines** with **369 segments** across **10 pipeline types**, **10 fluid families**, **10 global regions**, and **7 terrain types**, with **150,137 rows** linked across **12 tables** spanning **7 days of 180-minute time- series**.
- **Tables:** 12 TsFile table(s), 150,137 rows in total.
- `compressor_operations`: 1,344 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.023000 (UTC)
- `corrosion_erosion`: 20,664 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.368000 (UTC)
- `flow_assurance`: 20,664 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.368000 (UTC)
- `hydraulic_profiles`: 20,664 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.368000 (UTC)
- `leak_detection`: 3 rows, 2025-01-03 09:00:00 → 2025-01-03 21:00:00 (UTC)
- `optimization_labels`: 20,664 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.368000 (UTC)
- `pipeline_master`: 369 rows, 1970-01-01 00:00:00 → 1970-01-01 00:00:00.368000 (UTC)
- `pump_station_operations`: 3,752 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.066000 (UTC)
- `scada_telemetry`: 20,664 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.368000 (UTC)
- `thermal_profiles`: 20,664 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.368000 (UTC)
- `transient_events`: 21 rows, 2025-01-01 06:00:00 → 2025-01-07 12:00:00 (UTC)
- `valve_operations`: 20,664 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.368000 (UTC)
## Schema (TsFile structure)
### `compressor_operations.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (7): `pipeline_id` (string), `compressor_id` (string), `suction_pressure_psi` (double), `discharge_pressure_psi` (double), `compression_ratio` (double), `efficiency_pct` (double), `fuel_gas_mscfd` (double)
### `corrosion_erosion.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (7): `pipeline_id` (string), `segment_id` (string), `corrosion_rate_mpy` (double), `erosion_index` (double), `wall_loss_pct_est` (double), `leak_probability_score` (double), `integrity_state` (string)
### `flow_assurance.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (7): `pipeline_id` (string), `segment_id` (string), `wax_risk_score` (double), `hydrate_risk_score` (double), `slugging_risk_score` (double), `wax_deposition_thickness_mm` (double), `flow_assurance_state` (string)
### `hydraulic_profiles.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (13): `profile_id` (string), `pipeline_id` (string), `segment_id` (string), `pressure_psi` (double), `downstream_pressure_psi` (double), `pressure_drop_psi` (double), `flow_bpd` (double), `velocity_fps` (double), `reynolds_number` (double), `friction_factor` (double), `flow_regime` (string), `mass_balance_error_pct` (double), `event_active` (int64)
### `leak_detection.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (8): `leak_id` (string), `pipeline_id` (string), `segment_id` (string), `leak_rate_bpd` (double), `pressure_signature_score` (double), `detection_delay_sec` (int64), `isolated_flag` (int64), `estimated_loss_bbl` (double)
### `optimization_labels.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (7): `pipeline_id` (string), `segment_id` (string), `optimization_score` (double), `failure_risk_score` (double), `efficiency_grade` (string), `recommended_action` (string), `event_type` (string)
### `pipeline_master.tsfile`
- **Time** (INT64, milliseconds) — synthetic row index over the stable source order; this table has no clock column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (21): `pipeline_id` (string), `segment_id` (string), `pipeline_type` (string), `primary_fluid` (string), `region` (string), `terrain` (string), `segment_order` (int64), `length_km` (double), `diameter_in` (double), `wall_thickness_in` (double), `roughness_mm` (double), `elevation_start_ft` (double), `elevation_end_ft` (double), `material_grade` (string), `coating_type` (string), `insulation_type` (string), `install_year` (int64), `maop_psi` (double), `design_flow_bpd` (double), `pigging_capable` (int64), `scada_enabled` (int64)
### `pump_station_operations.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (8): `pipeline_id` (string), `station_id` (string), `rpm` (double), `efficiency_pct` (double), `suction_pressure_psi` (double), `discharge_pressure_psi` (double), `power_kw` (double), `cavitation_risk_score` (double)
### `scada_telemetry.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (9): `pipeline_id` (string), `segment_id` (string), `sensor_id` (string), `sensor_type` (string), `signal_value` (double), `engineering_unit` (string), `telemetry_latency_ms` (int64), `quality_flag` (string), `drift_flag` (int64)
### `thermal_profiles.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (8): `thermal_id` (string), `pipeline_id` (string), `segment_id` (string), `temperature_f` (double), `ambient_temp_f` (double), `heat_loss_btu_hr_ft` (double), `thermal_gradient_f_per_km` (double), `joule_thomson_cooling_f` (double)
### `transient_events.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (7): `event_id` (string), `pipeline_id` (string), `event_type` (string), `event_duration_min` (int64), `operator_response_delay_sec` (double), `severity_score` (double), `root_cause` (string)
### `valve_operations.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (6): `pipeline_id` (string), `segment_id` (string), `valve_id` (string), `valve_position_pct` (double), `throttling_state` (int64), `response_latency_sec` (double)
## Conversion notes
- One TsFile per source CSV (12 tables); each table is stored as a single device, so the rig / well / tank / equipment / sensor identifiers stay ordinary FIELDs.
- Time = the table's own clock column as INT64 milliseconds (event timestamps, sample or inspection dates, and daily record dates). The clock columns used here are `timestamp`.
- Tables with no clock column (`pipeline_master`) use a synthetic row index over their stable source order as Time.
- No column is dropped. Rows that share a timestamp are ordered by a 1 ms step in stable source order, so daily tables keep their exact calendar day.
## Usage
> **Read this dataset with the Java SDK.** It is written with the `zstd` compressor. The Apache TsFile Java SDK reads every compressor, but the Python SDK (`pip install tsfile`) implements only `UNCOMPRESSED`, `SNAPPY`, `GZIP` and `LZ4`; opening this file with it yields no rows.
Read a converted file with the Apache TsFile Java SDK (`org.apache.tsfile:tsfile`):
```java
import org.apache.tsfile.file.metadata.IDeviceID;
import org.apache.tsfile.read.TsFileReader;
import org.apache.tsfile.read.TsFileSequenceReader;
import org.apache.tsfile.read.common.Path;
import org.apache.tsfile.read.expression.QueryExpression;
import org.apache.tsfile.read.query.dataset.QueryDataSet;
import org.apache.tsfile.write.schema.MeasurementSchema;
import java.util.ArrayList;
import java.util.List;
String path = "compressor_operations.tsfile";
try (TsFileSequenceReader sequenceReader = new TsFileSequenceReader(path);
TsFileReader reader = new TsFileReader(sequenceReader)) {
// Devices are enumerated as IDeviceID objects. Tables with TAG columns
// have multi-segment device ids that cannot be rebuilt from their string
// form, so always use getAllDevices() rather than getAllDeviceIds().
for (IDeviceID device : sequenceReader.getAllDevices()) {
List<Path> paths = new ArrayList<>();
for (MeasurementSchema schema : reader.getMeasurement(device)) {
String name = schema.getMeasurementName();
if (name != null && !name.isEmpty() && !name.equalsIgnoreCase("Time")) {
paths.add(new Path(device, name, true));
}
}
QueryDataSet dataSet = reader.query(QueryExpression.create(paths, null));
while (dataSet.hasNext()) {
System.out.println(dataSet.next());
}
}
}
```
## Source & license
- Original dataset: [`xpertsystems/oil024-sample`](https://huggingface.co/datasets/xpertsystems/oil024-sample)
- Source card title: OIL-024 — Synthetic Pipeline Flow Dataset (Sample)
- License: cc-by-nc-4.0 (as declared by the original dataset).