Rows 80-119 of the 120 x 320 tactile canvas are removed from every frame: black padding in 756 episodes, sensor rows 8-11 in the 78 episodes recorded with a 12 x 32 grid (marked by tactile_source_rows in the episode metadata). Head, wrist and numeric data are unchanged. The previous streams remain at the arms14-five-cameras tag.
10 days ago
Remove RealSense videos and metadata from the dataset
Delete all four RealSense video files, including the placeholder, and remove camera features, statistics, episode references and availability entries. Keep the five RGB/tactile heatmap streams, all numeric tables and all 834 episodes unchanged. No video files are uploaded.
Keep 14 arm joints, actions, joint torques and bilateral EE estimates
Reduce numerical signals to 14-axis arm position, action and physical joint torque, plus two 6D TCP wrench estimates. Remove tactile raw arrays, lower-body and other joints, motor torques, diagnostics, frame masks and source indices. Keep only standard LeRobot bookkeeping fields alongside the five signals. Move torque and camera availability to episode metadata. Preserve all 834 episodes, 463905 frames at 15 Hz, retained numeric values and all 449 videos. No video files are uploaded. Update statistics, documentation, checksums and the environment figure. Include a reproducible projection and full-value verification script.
Unify all 834 robot episodes as a visualizable 15 Hz LeRobot v3 dataset
Move the collection to standard root data/meta/videos with continuous episode indices and the default frame-table config. Keep all 834 episodes; sample each 30 Hz episode at source frames 0,2,4,... for 463,905 total frames at 15 Hz. Preserve every retained source numeric value and all 431,172 torque/TCP frames. Use named 31-axis fields and explicit availability masks. Pad video canvases without resizing or cropping; preserve already-compatible video bytes. Include source mappings, scripts, checksums and viewer links. The original mixed-rate session collection remains at the session-collection-tcp-wrench tag.
Add bilateral TCP wrench estimates from recorded joint torques
Add local hand-mount [Fx, Fy, Fz, Mx, My, Mz] estimates for 796 episodes / 431,172 frames. Use a scaled damped Jacobian-transpose inversion of physical joint torques; include fitting residuals and condition diagnostics. Keep 38 episodes without torque unmodified and flag availability in the catalog. Preserve all original observations and videos; update feature definitions, episode/global statistics and checksums. Include the kinematic model, reproducible scripts and tests. These are uncompensated actuator-equivalent wrenches, not calibrated contact-force measurements.