text stringlengths 1 2k | question stringclasses 1
value | answer stringclasses 1
value | label stringclasses 1
value | origin stringclasses 18
values |
|---|---|---|---|---|
Liu et al. [155] have proposed a macromolecular organic compound that can form complex with copper oxides only when kinetic and frictional energy are imposed on the surface.
Lee and Robert [158] used oxalic acid dehydrate and an amine-based cleaning composition to remove the residual inorganic materials formed during ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
There are several reports on post-CMP cleaning formulations. HF-based cleaning formulations are not recommended for Cu because they induce corrosion and are detrimental to Si-based dielectrics. Murakami and Ishikawa
[162] suggested that the pH of the cleaning solution should lie outside the range 3e10 because BTA forms... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
$${\rm Cu(I)BTA+R(NH_{2})_{2}\!\rightarrow\!\left[Cu\big{(}R(NH_{2})_{2}\big{)}\right]^{+}+BTA^{-}}$$ (10.3-15) $${\rm Cu(II)BTA+R(NH_{2})_{2}\!\rightarrow\!\left[Cu\big{(}R(NH_{2})_{2}\big{)}\right]^{2+}+BTA^{-}}$$ (10.3-16)

A surfactant is incorporated in the cleaning solution t... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Cleaning solutions containing fluorine and amine compounds are commonly employed to clean the post-etching surface [170e173]. Tsang et al. [170]
showed that cleaning the surface in a single wafer system using a fluoride-based cleaning solution is more effective compared with that of amine-based cleaning solutions in te... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 10.4 Tungsten 10.4.1 Surface Morphology And Composition Of Tungsten
As discussed in Section 10.2, Al is a widely used material for the metallization of ICs, as it possess high conductivity and low contact resistance besides good adherence to Si and SiO2 [177,178]. However, the electromigration and spiking of Al thr... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Several authors [192e194] have reported the deposition of W using LPCVD
to obtain conformal and good fill characteristics up to the 90-nm technology node. Kaplan et al. [195] investigated W deposition from tungsten hexacarbonyl (W(CO)6) using a hot-wall LPCVD reactor at 200e580C with H2 as the carrier gas and with the ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
2WF6 + 3S1 - 2W + 3S1F4
(100 nm) voids with a resistivity of w19 mU-cm. Films deposited at 540C
exhibited high-purity (w0.95 at%) polycrystalline a-W, with low resistivities
(18 23 mU-cm) and a tendency toward a (100) orientation. However, vacuum annealing at 900C further reduced the resistivity to w10 mU-cm
(approxim... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Bain et al. [179] and Melliar-Smith et al. [200] highlighted that H2-reduced CVD W films show excellent adhesion to Si substrates and also achieve good uniformity. The reduction reaction takes place:
$$3\mathrm{Si}+2\mathrm{WF}_{6}\!\rightarrow\!2\mathrm{W(s)}+3\mathrm{SiF}_{4}$$
$$(10.4\text{-}18)^{2}$$
3Si þ 2WF6/2... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Kalanyan et al. [202] used the ALD processes to deposit conformal and uniform 10-nm W films on SiO2 substrates used for sub-10-nm high-storage memory devices. Other research confirmed that the addition of H2 delays W nucleation on SiO2 thereby expanding the ALD selectivity and reducing volcano defects [203]. In additio... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||

## 10.4.2 W Passivation Process And Contamination Issues
Passivation of W is necessary to protect its surface from aggressive environments during the fabrication of microelectronic devices. The typical W CMP
process uses a single polishing step that not only removes the overburden ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Tamboli et al. [183] used KIO3 and H2O2 oxidizers in W CMP to passivate the surface. There is evidence that W shows an excellent passivation behavior in both KIO3 and H2O2 solutions. However, the current density in the passivation regime for H2O2 is almost one order of magnitude higher than in KIO3 solution. Tamboli et... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
In another investigation, the combination of mixed oxidizers is proposed, adding KIO3 and Fe(NO3)3 into H2O2 for corrosion protection [216]. The researchers observed that the mixture of 0.1 M KIO3 with 5 wt% H2O2 has a decrease in corrosion potential with an increase of pH, whereas 0.1 M KIO3 with the mixture of 0.1 M ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||

the W surface, whereas slurries containing oxalic acid and H2O2 induced a porous oxide layer.
$$\mathrm{Fe}^{2+}+\mathrm{HOOH}\!\rightarrow\!\mathrm{Fe}^{3+}+\mathrm{H}_{2}\mathrm{O}+\,\bullet\!\mathrm{OH}$$
$$(10.4\text{-}22)$$
$$(10.4\text{-}23)$$
$$\mathrm{Fe}^{3+}+\mathrm{HOOH}... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 10.5 Cobalt 10.5.1 Surface Morphology And Composition Of Cobalt
Cobalt is a potential candidate for interconnects when the linewidth is <10 nm because it offers lower resistivity because of its short free mean path of electrons. Also, Co can be used in place of the Ta/TaN bilayer as a Cu diffusion barrier and can p... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
The deposition of Co by CVD and ALD is currently being explored and is preferred for smaller technology nodes [224e228]. Various precursors are claimed for both CVD and ALD processes. For example, the precursors such as Cp2Co (where Cp ¼ C5H5, cyclopentane), CpCo(CO)2, and Co(Co)NO.
Co2(CO)8 are suggested to deposit C... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 10.5.2 Passivation Process And Contamination Issues
**Co + 2H${}^{+}$ - Co${}^{2+}$ + H${}_{2}$**
After deposition, Co must be polished by CMP for delineation. However, Co is susceptible to corrosion via the dissolution of Co2þ ions as shown in Eq. (10.524). Thus tuning the slurry chemistry with suitable oxidizer... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||

The Pourbaix diagram shown in Fig. 10.5-15 reveals that self-passivation occurs only at neutral and alkaline media, whereas in acidic media active dissolution occurs. In neutral and alkaline media, the passive film mainly consists of CoO; Co(OH)2 is present in the inner layer, where... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
The Cu-BTA acts as a better inhibitor especially in neutral media than the BTA alone.
Han et al. [9] proposed the mechanism for the Co CMP process. According to this mechanism, defects can be controlled in addition to controlling the removal rate if the slurry chemistry is judiciously tuned. To achieve this, the conce... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
The main issues with Co post-CMP cleaning processes are uniform corrosion from chemical contact and galvanic corrosion between Co and Cu that are in contact with each other. Thus cleaning solutions must be formulated in such a way that they reduce both uniform and galvanic corrosion. The main driving force behind galva... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
As the IC pattern size is reduced from micrometers to nanometers, the transition metal with superior properties such as Co may replace the traditional Cu and W. Among the various deposition techniques, Al is usually deposited by sputtering, Cu is deposited by ECD, W is deposited by PVD and CVD, and Co is deposited by P... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## References
[1] P. Wrschka, J. Hernandez, G.S. Oehrlein, J. King, J. Electrochem. Soc. 147 (2) (2000) 706.
[2] T.H. Park, Massachusetts Institute of Technology (Ph.D. thesis), 2002. [3] S. Seal, S.C. Kuiry, B. Heinmen, Thin Solid Films 423 (2013) 243. [4] L. Taylor, Am. Soc. for Metals, Metals Handbook, Properties ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[16] A.Y. Musa, in: S. Razavi (Ed.), Chapter 3, Recent Researches in Corrosion Evaluation and Protection, InTech, Rijeka, Croatia, 2012.
[17] S. Wolf, Silicon Processing of the VLSI Era, vol. 2, Sunset Beach, California, 1990, p. 264.
[18] S. Wolf, Silicon Processing of the VLSI Era, vol. 2, Sunset Beach, California,... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[31] Y.Q. Xiong, X.C. Li, Q. Chen, W.W. Lei, Q. Zhao, L.J. Sang, Z.W. Liu, Z.D. Wang, L.Z. Yang, Chin. Phys. B21 (7) (2012) 078105.
[32] R.A. Levy, M.L. Green, J. Electrochem. Soc. 134 (1987) 37. [33] M. Ritala, M. Leskela, Atomic Layer Deposition, vol. 1, Academic Press, San Diego, California, 2001.
[34] J.L. Yong, ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[48] S. Hens, J. Van Landuyt, H. Bender, W. Boullart, S. Vanhaelemeersch, Mater. Sci. Semicond. Proc. 4 (1) (2001) 109.
[49] B.C. Bunker, G.C. Nelson, K.R. Zavadil, J.C. Barbour, F.D. Wall, J.P. Sullivan, D.R. Baer, J. Phys. Chem. B106 (18) (2002) 4705.
[50] K.H. Baek, Y.S. Yoon, J.M. Park, K.H. Kwon, C.I. Kim, K.S. ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[64] Y.H. Hsien, H.K. Hsu, T.C. Tsai, W. Lin, R.P. Huang, C.H. Chen, J.Y. Wu, Microeletron.
Eng. 92 (2012) 19.
[65] T. Shinzawa, K. Sugai, Y. Hayashi, T. Nakajima, S. Kishida, H. Okabayashi, T. Yako, Electron. Commun. Jpn. (Part II Electron. 79 (5) (1996) 88.
[66] S. Yun, J.H. Park, S.H. Han, J.D. Lee, C. Hong, H. C... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[77] D.J. Hagen, I.M. Povey, S. Rushworth, J.S. Wrench, L. Keeney, M. Schmidt, M.E. Pemble, J. Mat. Chem. C2 (43) (2014) 9205.
[78] P.G. Gordon, A. Kurek, S.T. Barry, ECS J. Solid State Sci. Technol. 4 (1) (2015) N3188. [79] S. Shivashankar, A. Mane, P. Dagur, in: S. Shivashankar, A. Mane, P. Dagurs (Eds.), ISTC
2004 ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[93] I. Das, S.S. Mishra, N.R. Agrawal, S.K. Gupta, J. Indian Chem. Soc. 80 (2003) 351.
[94] V.A. Vas'ko, I. Tabakovic, S.C. Riemer, Electrochem. Solid State Lett. 6 (2003) C100. [95] C. Lingk, M.E. Gross, W.L. Brown, Appl. Phys. Lett. 74 (5) (1999) 682.
[96] L. Vanasupa, Y.C. Joo, P.R. Besser, S. Pramanick, J. Appl.... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[107] K.K. Choi, J.H. Yun, S.W. Rhee, Thin Solid Films 429 (2003) 225. [108] L. Vazquez, J.M. Albella, R.C. Salvarezza, A.J. Arvia, R.A. Levy, D. Perese, Appl. Phys.
Lett. 68 (2001) 1285.
[109] D.H. Zhang, S.W. Loh, C.Y. Li, P.D. Foo, J. Xie, Surf. Rev. Lett. 8 (2001) 533.
[110] L. Nolan, K. Cadien, in: M. Stepanova... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[124] G.W. Poling, Corros. Sci. 12 (1970) 359.
[125] Y. Ling, Y. Guan, K.N. Han, Corrosion 51 (1995) 367. [126] T. Notoya, M. Satake, T. Ohtsuka, M. Sato, D.P. Schweinsberg, J. Corros. Sci. Eng. 6
(2003) C076.
[127] S. Tamilmani (Ph.D. thesis), University of Arizona, 2005. [128] D.J. Tromans, J. Electrochem. Soc. 145... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[140] M. Finsgar, I. Milosev, Corros. Sci. 52 (9) (2010) 2737.
[141] R. Subramanian, V. Lakshminarayanan, Corros. Sci. 44 (3) (2002) 535.
[142] S. Abd EleMaksoud, A. Zastita, Materijala 49 (2) (2008) 3.
[143] B.J. Cho, S. Shohei, H. Satomi, J.G. Park, Appl. Surf. Sci. 384 (2016) 505. [144] N.K. Allam, H.A. Nazeer, E... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[156] D.W. Peters, Proc. Mat. Res. Soc. Symp. 991 (2007) 215.
[157] C.F. Yeh, C.W. Hsiao, W.S. Lee, Appl. Surf. Sci. 216 (2003) 46.
[158] S. Lee, S. Robert, U.S. Patent Application 10/421,706, filed (April 24, 2003).
[159] R.P. Venkatesh, T.Y. Kwon, Y.N. Prasad, S.R. Ramanathan, J.G. Park, Microeletron. Eng.
102 (2... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Eng. 46 (1e4) (1999) 307.
[174] Q.T. Le, M. Claes, T. Conard, E. Kesters, M. Lux, G. Vereecke, Microeletron. Eng. 86 (2)
(2009) 181.
[175] J.S. Heo, J.H. Oh, H.J. Shin, N.I. Lee, Solid State Phenom. 145 and 146 (2009) 331. [176] C.K. Chang, T.H. Foo, M. Murkherjee-Roy, V.N. Bliznetov, H.Y. Li, Thin Solid Films 462
(2... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[189] G.S. Chen, L.C. Yang, H.S. Tian, C.S. Hsu, Thin Solid Films 484 (1e2) (2005) 83.
[190] P. Paris, M. Aints, M. Laan, M. Kiisk, J. Likonen, J. Kolehmainen, S. Tervakangas, Fusion Eng. Des. 84 (7e11) (2009) 1465.
[191] Y. Pauleau, Thin Solid Films 122 (1984) 243.
[192] H. Korner, Thin Solid Films 175 (1989) 55.
... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[205] http://electroiq.com/blog/2016/08/lam-research-enables-next-generation-memory-withindustrys-first-ald-process-for-low-fluorine-tungsten-fill/.
[206] K. Xu, S.H. Shen, J. Fung, H. Iravani, I. Carlsson, T.Y. Liu, K. Mikhaylich, ECS J. Solid State Sci. Technol. 5 (6) (2016) P361.
[207] O.H. Gokce, J.T. Sears, T. S... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[219] C.K. Yan, (Graduate thesis), Hanyang University (2008).
[220] J.Y. Jeong, W.G. Lee, Electrochem. Solid State Lett. 6 (3) (2003) G45. [221] O.E. Kongstein, G.M. Haarberg, J. Thonstad, ECS Trans. 33 (34) (2011) 3. [222] Q. Huang, T.W. Lyons, W.D. Sides, J. Electrochem. Soc. 163 (13) (2016) D715. [223] E. Shalyt, M... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[234] J. Park, H.B.R. Lee, D. Kim, J. Yoon, C. Lansalot, J. Gatineau, H. Chevrel, H. Kim, J. Energy Chem. 22 (2013) 403.
[235] K. Kim, K. Lee, S. Han, W. Jeong, H. Jeon, J. Electrochem. Soc. 154 (2007) H177. [236] J.M. Kim, J.B.R. Lee, L. Lansalot, C. Dussarrat, J. Gatineau, H. Kim, Jpn. J. Appl. Phys.
49 (05FA10) (2... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| Chapter Outline 11.1 Chemical and Water Monitoring Overview 620 11.2 Chemical Monitoring 621 11.2.1 Chemical Monitoring Techniques 621 11.2.2 Wet Chemical Monitoring 623 11.2.3 Chemical Monitoring Procedure 624 11.3 Optical Absorption Spectroscopy 626 11.3.1 Optical Absorption Spectroscopy Overview 626 11.3.2 Molecul... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 11.3.7.1 ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 11.3.7.3 ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 11.3.8.1 ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 11.4 ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 11.4.2 ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 11.4.3.1 ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Handbook of Silicon Wafer Cleaning Technology. https://doi.org/10.1016/B978-0-323-51084-4.00011-3 Copyright © 2018 Elsevier Inc. All rights reserved. 619
| 11.4.3.3 | Installation of Electrodes | 650 | | | |
|-----------------|----------------------... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Now, the integrated circuit (IC) industry realizes the relationship between chemical concentration and its ability to remove contamination. In addition, monitoring ultrapure water (UPW), not only to confirm its ultrapure state but also to assure that the chemicals used for wet processing steps are completely removed du... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
The sensor must have high resolution and accurately measure a wide range of concentrations. Plus, the monitor must not be a source of contamination itself.
## 11.2 Chemical Monitoring 11.2.1 Chemical Monitoring Techniques
An engineer can monitor chemical concentration by grabbing samples from the process tool and tak... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
There are many methods of measuring chemical concentrations, in which one subset is in-line chemical monitoring. These methods are discussed in this section.
Titration can be used to quantitatively monitor a variety of chemicals, such as aqueous solution, which include acids, bases, and oxidizing agents. Autotitrators... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Monitoring concentration by means of refractive index measurement is temperature sensitive. The measure of the RI of chemicals and solutions for etching, cleaning, and surface conditioning, along with chemical-mechanical polishing slurry and electrochemical deposition solution, is used in semiconductor manufacturing. C... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
pH is the measure of the acidity or alkalinity of an aqueous solution, which is based on the number of hydrogen ions (Hþ) or hydroxyl ions (OH) in the solution [9]. In water, acids dissociate to produce Hþ, whereas bases dissociate to produce OH. The amount of these ions in the solution is related to the pH:
pH ¼ - log... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Furthermore, acids and bases interact with water molecule and thus influence the chemical bonds of water, allowing NIR to also monitor these solutions
[12,13]. With respect to optical absorption, this chapter will focus mainly on NIR.
## 11.2.2 Wet Chemical Monitoring
Chemical and water monitoring can be integrated i... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
If used in a closed-loop control system, such as a wet bench tank, monitoring helps maintain the ideal concentrations of the process chemical or chemicals. For example, this is especially important for sulfuric acid (H2SO4),
H2O2 mixture (SPM), and SC-1 (APMdammonium hydroxide þ H2O2 mixture), where the chemicals have ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
The use of chemical monitoring often proves useful when a new process is being introduced into the production line where the optimum process parameter ranges must being determined. Chemical concentrations can be correlated to the results, such as the etching rate and even device performance, as part of understanding a ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| TABLE 11.2-1 | Chemicals, Solutions, and Formulations |
|------------------------------------------------------------------------------------------------------|-------------------------------... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| DSPþ | H2SO4 H2O2 HF |
| Aluminum-compatible photoresist | H2O ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
temperatures. Both components are unstable, especially at the high processing temperatures needed for this solution, for example, >65C. H2O2 decomposes into water (H2O) and oxygen (O2), especially in a basic solution such as SC-1, and ammonia evaporates over time. As a result, SC-1 cannot be purchased as a ready-made m... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Sulfuric acid and hydrogen peroxide mixture (SPM), sometimes called Piranha, is another unstable mixture that is prepared on site, typically for photoresist stripping and residue removal. Fresh mixing of H2SO4 and H2O2 solutions spontaneously heat to boiling, and the process generally takes place at about 120C. The amo... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Ultrapure water (UPW), in the case of semiconductor processing deionized water (DIW) monitoring using resistivity, is commonplace. The water is monitored not only at the point of use but also upon production, upon arrival at the processing tool, and while wafers are processed. Any trace contamination in the water will ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
The well-known laws of classical physics describe the motion of large objects, such as billiard balls, but do not properly describe the behavior of atoms and molecules. On this microscopic level the laws of quantum mechanics apply. The atoms and molecules do not have a continuous range of available energy states and th... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Energy is related to the wavelength of light through Planck's equation [21]:
E ¼ hn (11.3-2)
where E is the energy, h is Planck's constant, and n is the frequency, which is related to the wavelength by the following equation:
y ¼ c=l (11.3-3)
where c is the speed of light in a vacuum and l is the wavelength.
When a mo... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
When a photon in the low-energy IR range is absorbed by a molecule, it can change the degree of vibration, also called the "vibrational state" of a molecule.
The precise wavelength required to do this depends on the molecule's structure and physical properties, for example, the weight of its atoms, the strength of the... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Absorption peaks of overtones are broader, and can overlap, and therefore special mathematical techniques are needed to extract the relevant information from the spectra.
There is one more important point concerning ions. While molecules have chemical bonds, and thus each molecule has clearly defined molecular vibrati... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
$$I_{l}=I_{0}e^{-\alpha c l}$$
c ¼

$$(11.3\text{-}4)$$
$3\text{=}5$).
al (11.3-5)

The BeereLambert law holds for mixtures of chemicals, as long as there are not chemical reactions or physical interactions between the various chemical species.... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||

used for the calibration. Thus chemometrics, a method of multivariate analysis, is used to correlate the spectrum with the concentration [33] . By using this method, information from the entire spectrum, not just one wavelength, can be used to extract the relevant information, such ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
PCA is a means of analyzing data and reducing the number of dimensions that must be dealt with. The PLS fit goes a step further and correlates the data with a matching set of reference data. The PLS method is commonly used in chemometrics to correlate the measured spectra with the reference concentration data. The net ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||

specific sample. The cloud of points in the lower graph (B) shows the second and third components of this analysis. In Fig. 11.3-4B the differences between the samples are no longer visible, because most of that difference is expressed in the first two principal components, Fig. 11.... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||

of 0 at 2.25 mm, meaning that this part of the spectrum does not correlate well with the concentration. The spectrum at 1 mm would receive a larger correlation value than the spectrum at 3 mm, because the spectrum at 1 mm contains better information about the concentration, in this ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Fig. 11.3-6 shows a schematic diagram of the steps involved in the calibration procedure.
There are several points to consider when performing a calibration: (1)
coverage of the complete range of relevant chemical compositions, (2)
coverage of the complete range of temperatures, (3) use of laboratory reference data, (... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
The use of reference methods should be consistent when verifying a calibration sample. If the calibration sample used gas chromatography, then any verification work should be done using the same method, preferably in the same laboratory.
Some chemicals are unstable. The concentration of some materials will deteriorate... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Temperature will affect the absorption spectra. Generally processes are run at a constant temperature, but when this is not the case, temperature variations must be addressed. Common methods include (1) taking a small sample stream from the process, cooling it, and stabilizing its temperature to a set value, (2)
measur... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
There are several methods available for measuring the optical absorption spectrum of a chemical. For these methods there is at least one light source, some means of separating the different wavelengths of light, and a detector.
Light sources include halogen lamps that produce light over a wide range of wavelengths, bu... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
An alternate design, in which LEDs serve as wavelength specific elements, results in a simple, reliable instrument, although one that is limited in application, as are most nondispersive devices.
## 11.3.6.2 Dispersive Absorption
The most common spectrometers use diffraction gratings to split the light into its wavel... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Spectrometer stability over time is an important issue. There are a number of factors that can cause instrument drift. Instrument manufacturers take these into account and provide for correction of these sources of drift.
Light source intensity can change over time. This can be compensated for by measuring the light s... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
The method has the simplicity of a single detector, with the advantage of relatively high light throughput. It does require fine mechanics to ensure proper motion of the moving mirror. Reading the detector output at high speed reduces the signal to noise ratio, although the ability to use a larger detector overcomes th... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
For the spectrometer to measure the fluid's absorbance of light, there must be some means of guiding the light through the fluid. A flow cell is such a means. An in-line flow cell is composed of a chemical-compatible tube where the chemical can flow through the light beam, discussed later in this section. Note that the... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Finally, there are "clip-on" in-line flow cells that are easy to install on an existing or new recirculation line. There is no need to cut the line because the absorption spectrum is measured directly through a Teflon-based tubing of the chemical recirculating line. The advantage is ease of installation. However, owing... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
The flow cells must block out light originating from the ambient environment.
## 11.3.7.1 Factors That Interfere With Measurements
There are a few fluid properties that can interfere with measurement in the NIR. Bubbles are the most common issue. Bubbles are usually a result of H2O2 decomposition, in mixtures such as... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
The fluid flow to the measurement cell can be slow because of bubble removers, slow flow in a bypass line, or flow through a long, small-diameter tube to the instrument. In these cases the NIR instrument may provide updated readings at a very high rate, but the readings will not reflect the current situation in the che... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
NIR instruments may require repeat calibration for a number of reasons: light source replacement, changes in the optical system or, in some cases, periodic factory refurbishment and recalibration. On-site recalibration is generally a one-point calibration, or offset. This can be performed using a fluid with a known ref... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
In this example, there are six components, of which five are independent, whereas the concentration of the sixth component, H2O, is 100 wt% minus the sum of the other components. This means that the sample set must span a fivedimensional space. The boundaries of this space are defined by the concentration range that ea... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| TABLE 11.5-2 | Example of Experiment Design Component Mixture Ranges Process Information | | | | | |
|----------------|-----------------------------------------------------------------------------|-------|-------|-------|-------|-------|
| Component | A % ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 6 | 10.50 | 19.62 | 22.71 | 5.96 | 15.11 | 26.10 |
| 7 | 8.42 | 26.37 | 16.40 | 10.16 | 15.26 | 23.40 |
| 8 | 8.32 ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
many independent components. Fig. 11.3-10 shows a plot of expected concentration distribution for two of the six components.
Temperature is another concern with respect to accurate calibration.
Although processes are usually run at a constant temperature, temperature variations do occur, and a fab may decide to chang... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||


and the noise in the spectroscopic system. In this case, it is 0.996, which is quite good.
The calibration results also include some statistical information. The RMSEP, or root mean squared error of prediction, gives a measure of the expected RM... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Fig. 11.3-12 shows results of the change in concentration of a six-component mixture, one of which is water, over time. The graphic shows the change in the

concentration and the recent history. Note the changes in the concentrations when dosing of the chemical mixture occurs, indic... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 11.4.1 Conductivity
Conductivity is a measure of the conductance of an electrical current through a material. Its unit is typically expressed in microSiemens/cm (mS/cm). In the case of wet processing chemicals, the material is an aqueous solution. For a current to be conducted through the aqueous solution, it must ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 11.4.2 Resistivity
Resistivity is the reciprocal of conductivity. Resistivity is a measure of the resistance of a material for a given length. Its unit is U cm. In applications such as UPW it is often used because the UPW ionic concentration, and thus the conductivity, is extremely low, for example, less than 1 mS/... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
$$I\;=\;{\frac{V}{R}}\;=\;V\times C$$
$$(11.4\text{-}11)$$
The ions in the aqueous solution migrate to the electrodes, the anions to the positively charged cathode and the cations to the negatively charged anode. However, salt deposition on the electrodes due to electrolysis can alter the resistance; therefore alterna... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Advanced conductivity instruments can vary the voltage applied to the electrodes, which enables the extension of the range of potentiometric measurements, and thus concentrations, even further. This allows advanced meters to be able to measure both high and low conductivities as well as the ultralow conductivity of UPW... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
$$E=\ E_{o}+$$
$$(11.4\text{-}13)$$
ared(11.4-13)
$${\frac{R T}{z F}}\ln\left({\frac{a_{o x}}{a_{r e d}}}\right)$$
where E is the electrode potential (V), Eo is the electrode potential at standard state (1 M at 25C and 1 atm), R is the ideal gas constant, T is the temperature, z is the number of electrons transferred... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Ion-selective electrodes are attractive to use for monitoring ionic aqueous solutions due to their long lifetime, adequate ion selectivity, accuracy, and the wide concentration range that they are capable of measuring. The response time to reach equilibrium while the ions charge the membrane can be on the order of appr... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
The pH electrode is based on potentiometric measurements with an ionselective electrode, in this case made of thin doped glass with extremely high selectivity for hydrogen ions in aqueous solutions. Because HF can etch the glass of the pH electrode, other materials are available. Typically, the reference electrode is i... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
State-of the-art electrodes incorporate temperature compensation algorithms into the electrode's control software, with the realization that if the composition of the process changes, the temperature compensation coefficient must also change.
## 11.4.3.2 Calibration Of Electrode Measurements
Calibration of electrodes... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Various conductivity solutions are available that comply with NIST standards
[57]. Factors that affect the calibration standards are contamination and impurities in the standard solution, such as CO2 that is dissolved in the aqueous solutions, forming additional ions from the H2CO3 [58], other inadvertent contamination... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Calibration of resistivity electrodes uses the same procedures and similar NIST traceable solutions as conductivity probe calibration, with the chosen calibration standards appropriate to resistivity calibration.
Calibration of pH electrodes uses buffer solutions, usually at three standard pH values of 4, 7, and 10. T... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Mounting the sensor in a vertical pipe with the fluid flowing in an upward direction is suggested. If the sensor must be installed in a horizontal pipe, place the sensor at an angle of 180 degrees to the pipe. Keep adequate clearance between the end of the sensor and the opposite pipe wall to keep response time as fast... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
In an IC manufacturing facility, the UPW that is generated is tightly controlled with respect to resistivity [63]. Monitoring of the UPW occurs at various places in the UPW manufacturing process and delivery system, plus at the point of use of the water, for example, during rinsing the wafers after wet chemical process... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
The ability to detect trace amounts of ions in the water using resistivity is the key to controlling the undesirable contamination. Resistivity instruments must be able to detect impurities of only a few tenths of a part per billion
(ppb), which equates to micrograms per liter [68]. If additional analysis of the water ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||

assure that most of the ions are removed before the rinsing process is completed. As shown in Section 11.4.3, temperature affects the resistivity of UPW. It is more difficult to measure the purity of hot water than cold water
[54,61,70] because of the temperature sensitivity, temper... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
ASTM standard D1125-14 outlines current methods for standardization of test methods for measuring the resistivity of water. Standards can be prepared using ASTM D1125-14 or NIST (National Institute of Standards and Technology) solutions [72].
## 11.4.5 Chemical Conductivity Measurements
Control of chemical concentrat... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 11.5 Future Of In-Line Chemical Monitoring
Wet chemistries are becoming more and more dilute over time. In the past, an SC-1 monitoring system could deal with >3 wt% H2O2, and accuracies of >0.1 wt% would suffice. The trend today is toward solutions with the H2O2 concentrations in the range of a few tenths of a per... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress |
Subsets and Splits