There are opposing needs in the field of chemical monitoring. On the one hand, repeatable, accurate, timely results are wanted, on the other hand, monitoring solutions need to be cost-effective, not just the purchase cost, but also the overall cost of ownership. Practical solutions must compromise between these conflic... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Today the trend is to more dilute solutions, and standard spectroscopic methods are reaching their limits. In addition, the acceptable concentration limits in new chemistries are quite narrow, making it risky to run process without monitoring the chemistry. This will lead the industry toward alternate methods, includin... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Another direction that we may see is the combination of existing methods, such as NIR, conductivity, refractive index, or the speed of sound to achieve better performance.
In-line measurement of metal contamination can monitor the bath until failure, for example, if a particular dirty wafer or the metal content in the... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[2] W. Zapka, A.C. Tam, Appl. Phys. Lett. 40 (4) (1982) 310. [3] Monitoring Sulphuric Acid Concentration, Sulphur Magazine, September/October 2016. [4] G.J. Moody, J.D.R. Thomas, in: H. Freiser (Ed.), Ion-Selective Electrodes in Analytical Chemistry, Springer, New York, 1978, p. 411.
[5] E. Scholz, Karl Fischer Titrat... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[17] C.N. Stedwell, N.C. Polfer, in: N.C. Polfer, P. Dugourd (Eds.), Laser Photodissociation and Spectroscopy of Mass-separated Biomolecular Ions, Springer, New York, 2013.
[18] P. Bouguer, Essai d'optique sur la gradation de la lumie`re, Jombert, 1729.
[19] E. Merzbacher, Quantum Mechanics, third ed., Wiley, New Yor... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[31] E. Shalyt, G. Liang, P. Bratin, C. Lin, in: M.K. Balazs (Ed.), Semiconductor Pure Water and Chemical Conference Proceedings (SPWCC), 2007, p. 19.
[32] B.C. Smith, Quantitative Spectroscopy: Theory and Practice, Academic Press, San Diego, CA, 2002, p. 12.
[33] T.W. Anderson, An Introduction to Multivariate Statis... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[43] S. Kanji, U.S. Patent 6,471,756, October 29, 2002.
[44] J.K. Crum, Anal. Chem. 42 (4) (1970) 107A.
[45] A.J. Bard, L.R. Faulkner, Electrochemical Methods: Fundamentals and Applications, second ed., Wiley, New York, 2001.
[46] C.C. Liu, in: J.D. Bronzino (Ed.), The Biomedical Engineering Handbook, second ed., CR... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[58] K.W. Pratt, W.F. Koch, Y.C. Wu, P.A. Berezansky, Pure Appl. Chem. 73 (11) (2001) 1783.
[59] S. Schoen, B. Pennington, S. O'Neil, Ultrapure Water 22 (4) (2005) 18.
[60] ITRS, Yield Enhancement Section, Table YE-3, 2015.
[61] K.R. Morash, R.D. Thornton, C.H. Saunders, A.C. Bevilacqua, T.S. Light, Ultrapure Water ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| Chapter Outline 12.1 Measurements of Particles and Defects | 660 | |
|--------------------------------------------------------------|----... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 12.2.1 | Overview of Defect and Particle Detection on Wafers | 662 |
| 12.2.2 | Ove... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 12.2.5.2 | Patterned Wafer Defect Inspection | 672 |
| 12.2.5.3 | Waf... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 12.3 | Particle Measurement in Liquid Chemicals | 677 |
| 12.3.1 | Opt... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Handbook of Silicon Wafer Cleaning Technology. https://doi.org/10.1016/B978-0-323-51084-4.00012-5 Copyright © 2018 Elsevier Inc. All rights reserved. 659 | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 12.3.1.1 | Special Considerations for Optical Particle Counters 680 | | |
|-----------------|---------------------------------------------------------------|---------------------------------|-----|
| 12.3.1.2 | Particle Counter Performance ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 12.5.1 | AMC Monitoring | 694 | |
| 12.6 | Future of Particle Contamination Measurements | 695 | |
| 12.6.1 | Particle Detection on Wafers ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 12.1 Measurements Of Particles And Defects 12.1.1 Overview Of Particulate Contamination And Defect Analysis
Detection of defects on the wafer surface is a critical step during the integrated circuit (IC) manufacturing process. Nondamaging and nondestructive defect monitoring allows the wafers quickly to be checked ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
3. Measurement of particle concentrations in the air and other gases. Presented in Section 12.4.
In addition, airborne molecular contamination (AMC) can directly or indirectly lead to defects on the wafer surface (refer to Chapter 2). Monitoring techniques for this contaminant is presented in Section 12.5.
## 12.1.2 ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 12.1.3 Overview Of Cleaning Process Steps And Equipment Requiring Particle Monitoring
Essentially every processing step in the manufacturing of an IC requires monitoring the number of defects, since researchers clearly have shown that yield is related to the amount of defects and particulate contamination [1,2].
P... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Defect monitoring equipment is typically based on an optical light scattering technology [5] with sufficiently high sensitivity to provide detection of very small defects or particles. This includes surface scanning technology [6]
used on wafer surfaces and laser-based optical particle counters (OPCs) for real-time par... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
The detection of the particle location on the wafer surface may help in the determination of the source of the contamination and may help in the recognition of trends within the wafer defectivity profile, thus helping to troubleshoot process problems that can lead to a decrease in yield. Monitoring is usually performed... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 12.2.2 Overview Of Particulate Contamination Analysis On Wafers
Many particle problems manifest themselves as defects on wafers and have the potential to cause yield loss [14]. Using a system to monitor defects on wafers is advantageous because the defect can be classified. Defects are classified by inspection tool... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 12.2.3 Particle Monitoring On A Wafer For Cleaning Tools
Successful particle control during wafer cleaning requires periodic monitoring of the performance of the cleaning equipment and processes. It is common practice to conduct particle-per-wafer-pass measurements of cleaning systems once a shift or once a day. Th... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||

Monitoring systems for particulate contamination starts with a particlegrade monitor wafer. The wafer is premeasured at the desired particle size sensitivity and then processed through the manufacturing equipment to be tested, after which a final particle count is taken. In most cas... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 12.2.3.1 Particle Monitoring Of Wet Stations
The particle-per-wafer-pass measurement on a wet processing station combined with routine data on chemicals, H2O, and N2 quality is adequate to alert an operator when the process begins to go out of control. When the particleper-wafer-pass measurement is not in control, ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
l With and without continuous drip of rinse tank nozzles for low flow. This determines if there is bacteria buildup in the nozzles.
Additional tests also can be performed to analyze the origin of the particles; some tests and the effects can be:
l Detection of high levels of total organic carbon (TOC) in the rinse tan... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
In addition to particles, wafer haze also is used to study the PRE of cleaning tools. In a study, the researchers used haze measurements to characterize local PRE with 600 mm - 600 mm lateral resolution [20]. The local haze is used to determine the cleaning efficiency in different regions of the wafer for different pro... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Particle partitioning tests are run to isolate the source of the particulate contamination. These tests are outlined:
l Entire process: process chamber with plasma, loadlock, and handler l Partition 1: handler only l Partition 2: handler and loadlock l Partition 3: process chamber without plasma, loadlock, and handler ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Defect inspection tools are able to give maps with coordinates and attributes defined for each defect to allow observation and classification of the type of defect, of which particles are one type [21]. Most commercially available tools also perform grading, also called review, and classification of defects. For the pu... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Sizing is the use of the integrated software of the system to determine the defect size. The size of the defect is determined and segmented into a bin based upon the intensity of the light scattering signal.
Classification is the use of software analysis tools to determine the type of defect by their light scattering ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 12.2.5 Defect Inspection Equipment 12.2.5.1 Unpatterned Wafer Defect Inspection
For defect inspection, a beam of light from a laser source is used to illuminate the wafer surface. In the presence of an imperfection, which can be a particle on the surface, surface roughness, or subsurface defect, the light is distor... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
As can be seen in Fig. 12.2-4, particles or other defects on the wafer surface will have a stronger scattering signal than the wafer surface.
Depending on the wafer type, desired sensitivity, signal to noise ratio, and tool type, an intensity threshold is set in the scan recipe. All scattering events with intensity hi... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||

A schematic of defect detection by light scattering is shown in Fig. 12.2-5. Particles and other discrete defects are not the only cause of light scattered from a wafer [35].
Surface roughness, organic films, residue, and other surface film from unwanted contaminants all result in ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Defect inspection on bare Si wafers is typically performed using light scattering tools [26,41]. Sensitivity and throughput are the primary focus of such tools designed for unpatterned wafer inspection. Sensitivity improvements in recent years have been obtained by moving from visible to ultraviolet (UV) wavelengths us... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||

UV-based tool is mostly due to surface defects and anomalies, giving more accurate and yield-relevant defect results [43]. Fig. 12.2-6 shows the inspection result on an SOI wafer, showing particles, haze, and shallow scratches detected by the haze analysis algorithm [44].
## 12.2.5... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Tunable broadband brightfield illumination technology has several advantages over a single-wavelength approach for meeting new inspection challenges and generating higher capture rates of yield-impacting defects [46].
Modeling studies as well as fab experience show that different defect types and device layers require... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
State-of-the-art patterned wafer inspection systems have detection limits below 10 nm, and throughputs ranging from a few wafer per hour to tens of wafers per hour [48].
## 12.2.5.3 Wafer Back Surface Defect Inspection
Back surface contamination, although not as immediately detrimental to the devices as defects on th... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
In addition to defect inspection, the location of film edge-bead removal
(EBR) lines relative to wafer center and to the top of the wafer is of interest.
Inspection cluster systems provide defect inspection, EBR metrology, and edge profile shape metrology: all-surface inspection and metrology at sensitivities as low a... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Current state-of-the-art commercially available technology has a limitation for detecting particles at 19 nm [42].
## 12.2.6.1 Calibration
Calibration of the particle monitoring system is crucial to the performance of the tool [52,53]. Methods used for calibration include using polystyrene latex
(PSL) or silica spher... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Standards for calibration have been developed with SEMI and Sematech
[55] and also by Mulholland et al. [56]. SEMI specification M53-0310 outlines the procedure for calibration of the scanning surface inspection systems
(SSIS). The suggested sizes of the PSL spheres for calibration range from the largest to the smalles... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
When calibrating a defect measurement system for the various size particles and defects that may be encountered, the hardware components of the systems are modified to optimize the detection of the scattered light. Multiple scattering channels and multiple detectors for use with a single-wavelength light source have be... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Repeatability is defined as the ability to take a statistically significant number of measurements and have an acceptably small variance between the measurement values to assure this value is correct [41]. The uncertainty of the measurement is expressed in the following terms:
$$C o V={\frac{\sqrt{\sigma_{R P T}^{2}+\... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 12.3.1 Optical Particle Counters
OPCs for liquids are the most popular instruments for measuring particles in UPW and process chemicals [58]. They provide a reliable, consistent, and efficient method for quantifying particle size and concentration. An OPC measures the equivalent optical size of particles based on t... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Commercially available volumetric particle counters are limited to 0.1-mm size sensitivity.

Nonvolumetric particle counters have tightly focused laser beams that

provide increased sensitivity compared with volumetric particle counters, as shown... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
The molecular light scattering from the fluid is dispersed across thousands or millions of pixels, making the background scattered intensity per pixel much lower than a conventional photodiode detector. When a particle is detected, its image on the detector is a very small subset of all the pixels, which results in a s... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Monitoring a high molecular scatter fluid with digital detector technology allows the particle counter to be operated in high scatter mode, which greatly reduces the effect of the background scattered light, as shown in Fig. 12.3-13.
12.3.1.1 Special Considerations for Optical Particle Counters There are special consi... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| TABLE 12.3-1 | Refractive Indices of Semiconductor Materials at |
|--------------------------------------------|----------------------------------------------------|
| 780 nm Particulate Material | Refractive Index |
| Silicon dioxide (S... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Rayleigh scattering theory [26] presents the scattering cross-section, ss, as:
$$\sigma_{s}=\left(2\pi^{5}/3\right)\times\left(d^{6}/\lambda^{4}\right)\times\left[\left(m^{2}-1\right)/\left(m^{2}+2\right)\right]^{2}$$ (12.3-2)
$$(12.3\text{-}3)$$
where d is the particle diameter, l is the wavelength of light, and m i... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
where d is the particle diameter, l is the wavelength of light, and m is the index of refraction contrast. The refractive index contrast:
m ¼ nparticle=nmedia (12.3-3)
where n is the refractive index. From Eq. (12.3-2), the Rayleigh scattering intensity is proportional to d6 and l4. Also, as m approaches 1, the Rayleig... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Fig. 12.3-14 shows the benefit of using a compression sampler at pressures of 45 psi (pounds per square inch). In this example, a pressure of 30 psi is insufficient and the bubbles are counted as 2-mm size particles.

Particle counting or optical coincidence occurs when more than on... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||

smaller particles. In extreme situations, total cumulative particle concentrations will decrease with increasing particle concentrations.
Contamination can impact the accuracy of particle counter results, for volumetric particle counters, in particular. Capillaries are particularly... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Changes in flow rates will affect the face velocity along the tubing and can cause particle shedding. Valves are especially prone to trapping and shedding particles and should always be fully opened or closed. Partially open valves may generate cavitation and continually shed particles.
## 12.3.1.2 Particle Counter Pe... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
In optical particle design, sensitivity comes with a trade-off with respect to the sample volume. Since the sample volume represents the amount of fluid

being examined per minute, a larger sample volume will result in more particles being detected. Since the number of particles det... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||


limits are normalized to these volumes. In Eq. ( 12.6 ), the value of 1.96 comes from a Student's t table of probability constants for the 95% upper control limit.
95% UCL = [(expected counts) + 1.96 × SD]/sample volume
$$(12.3\text{-}6)$$
A m... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Setting the sensitivity limit at 50% counting efficiency is important because it sets the sensitivity limit independent of the resolution of the particle counter. If values other than 50% were used, then the resolution would affect the sensitivity limit as shown in Fig. 12.3-19, resulting in inaccuracies when counting ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 12.3.1.4 Applications Of Particle Monitoring In Liquids
Particle counters can be used in-line, with a syringe sampler or with a compression sampler. Particle counters installed on pressurized delivery lines

provide continuous sampling and are less susceptible to contamination.
... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Hot UPW can form bubbles that may be counted as particles. The best approach to eliminating this possibility is the use of a small chiller or a long length of tubing before the particle counter. The chiller should be qualified before use to ensure that it does not shed particles.
## 12.3.1.6 Chemical Distribution Syst... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Monitoring of recirculating chemical baths can be accomplished with an in-line counter in the recirculation loop. However, it is usually preferable, depending on the processing speed, to directly monitor the bath, so that the particle counter measures the same fluid that comes in contact with the wafer.
A compression ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 12.3.2 Nonvolatile Residue Monitor
There are several nonvolatile colloidal species in UPW that deposit onto the surface of wafers during the rinsing and drying steps of a cleaning process.
These include colloidal silica, bacteria, particles, and certain ionic impurities.
Blackford et al. [74e76] describe a nonvol... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 12.4 Particle Measurement In Air And Gas
Particle counters that directly measure particles in air and gas are important tools for understanding exposure risk of wafers, reticles, and other sensitive components. Knowing the number of particles that are in the wafer environment is critical for the successful producti... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
SECTION
j IV Analytical and Control Aspects
| Number of Particles per Cubic Meter of Room Air by Micrometer Size | | | | | | |
|----------------------------------------------------------------------|------------|-----------|---------|--------|-------|------|
| Class ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
High-efficiency filters are used to remove them. However, not all particles can be removed and in some cases the filter can introduce contamination. If the filter experiences rapid changes in pressure or flow rate or mechanical failure, particle counters can be used to detect the excursion. Qualification of a gas distr... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 12.4.2 Particle Measurements In Air
Termed aerosol particle counters, these systems measure particles in air. This technology can be used to monitor wafer and reticle exposure to airborne particles in EFEMs, in the processing equipment atmospheric pressure staging area, and in equipment storage areas, such as FOUP ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
These interactions with highly engineered wafer and reticle surfaces can cause yield loss by changing the electrical, optical, chemical, or physical properties of the surface [80]. Some examples of this are metal thin film corrosion, hazing of optics, changes in surface wettability, T-topping of photoresist, thin film ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 12.6 Future Of Particle Contamination Measurements
Detection of smaller and smaller particles challenges the technological limits of traditional light-scattering techniques [84], both for counting nanoparticles in liquids, air, and on wafers. The challenges include problems due to the intensity of scattered light f... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Other approaches to optimize particle detection include illuminating the sample from numerous azimuth angles, to provide a lower detection limit verified by an analysis of the speckle signal that originates from the surface roughness of the substrate [92]. The multiple angles used simultaneously detect the particle or ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
The authors of the Handbook's second edition were Ed Terrell and Karen Reinhardt. The third edition authors wish to thank Mark Keefer, Paul Horn, and Kurt Haller for their contributions to this chapter. Thanks to Lisa Cheung and Uday Mahajan for contributions and John Stover for his helpful review of the chapter manusc... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[11] A. Carlson, T. Le, J. Hallen, Solid State Technol. 50 (6) (2007) 43. [12] J.D. Morillo, T. Houghton, J.M. Baue, R. Smith, R. Shay, in: IEEE/SEMI Advanced Semiconductor Manufacturing Conference and Workshop (ASMC), 2005, p. 49.
[13] K. Nakano, S. Owa, I. Malik, T. Yamamoto, S. Nag, in: SPIE Optical Microlithograph... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[24] M.E. Fossey, J.C. Stover, L.D. Clementi, US Patent 6,118,525 (2000). [25] C.R. Brundle, Y.S. Uritsky, in: A. Diebold (Ed.), Handbook of Semiconductor Metrology, Marcel Decker, N. Y., 2001, p. 547.
[26] J.C. Stover, Optical Scattering, second ed., SPIE Press, Bellingham, Washington, 1995.
[27] J.C. Stover, V. Iva... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[39] D.K. Chen, K. Sun, M. Yeh, C.C. Chen, in: Yield Management Symposium (YMS), KLATencor, Taiwan, 2006.
[40] D.K. Chen, A. Steinbach, M. Yeh, C.C. Chen, S.C. Chen, M.S. Liang, in: IEEE/SEMI
International Symposium on Semiconductor Manufacturing (ISSM), 2006.
[41] P.-F. Huang, Y.S. Uritsky, C.R. Brundle, in: A. Dieb... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[50] C. Saravanan, W. Yang, Z. Liu, M.F. Swisher, A. Tang, MICRO 22 (3) (April 2004) 29.
[51] T. Bearda, P.W. Mertens, F. Holsteyns, P. De Bisschop, R. Compen, A. van Meer, M.M. Heyns, Jpn. J. Appl. Phys. 44 (10) (2005) 7409.
[52] S.-H. Yoo, J. Weygand, J. Scherer, L. Davis, B. Liu, K. Christenson, J. Butterbaugh, N.... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[62] T. Pietrykowski, J. Mitchell, J. Ultrapure Water (May 2009).
[63] D. Rodier, in: Ultrapure Water Conference, December 2014.
[64] P. Scardina, R.D. Letterman, M. Edwards, J. Am. Water Works Assoc. 98 (7) (2006) 97. [65] A. Dey, in: N.N. Li, A.G. Fane, W.S. Winston Ho, T. Matsuura (Eds.), Advanced Membrane Technol... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[75] D.B. Blackford, G.J. Sem, T. Kerrick, in: Proceedings of the International Conference of Particle Detection, Metrology and Control, 1990, p. 546. Arlington, VA.
[76] D.B. Blackford, F. Zarrin, G. Sem, T. Kerrick, in: Proceedings of the Microcontamination Conference and Exposition, Canon Communications, San Jose, ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
[87] R. Bonam, H.-Y. Tien, A. Chou, L. Meli, S. Halle, I. Wu, X. Huang, C. Lei, C. Kuan, F. Wang, D. Corliss, W. Fang, J. Jau, Z.J. Qi, K. Badger, C. Turley, J. Rankin, in: SPIE Extreme Ultraviolet (EUV) Lithography VII, vol. 9776, 2016, p. 1C.
[88] B.D. Bunday, M. Mukhtar, K. Quoi, B. Thiel, M. Malloy, in: SPIE Metro... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| Chapter Outline 13.1 Introduction | 702 | | |
|---------------------------------------------------------... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 13.2 | Inorganic Contamination Analysis Techniques | 706 | |
| 13.2.1 ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 13.2.1.5 | Instrumental Analysis of the VPD Droplet 713 | | |
| 13.2.2 ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 13.2.7 | Auger Electron Spectroscopy | 728 | |
| 13.2.8 ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| 13.4 | Surface Morphology Analysis Techniques | 736 | | | |
|-----------------|------------------------------------------|-------|------|-----------------------------------------------------|-----|
| 13.4.1 | Atomic Force Microscopy ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Effective contamination monitoring programs have several metrology requirements that must be met in order to adequately support state-of-the-art device fabrication. The metrology must be able to quantify or qualitatively identify the contamination, that is, to determine the chemical identity of the contaminant. It must... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Elemental analysis, by far the most common, is when the concentration of an element is measured, regardless of its chemical state; e.g., the concentration of Fe is quantified, in units of atoms/cm2, whether it is present as Fe0, FeO,
Fe2O3, or Fe(OH)2. The second broad classification of inorganic analysis is the measur... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Additionally, metrology may determine if the contamination is present as a relatively homogenous film or as discrete islands or particles; such information may be useful in identifying and eliminating the source of the contamination.
Contamination may be transferred from various sources to a wafer through a wide range... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 13.1.3 General Selection Criteria For Ultratrace Metrology
The selection of the analytical technique to apply to a given situation is greatly dependent upon the information required. A valuable approach to take is to define the question that needs to be answered, if that question to be considered is "What is the le... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
l If full wafer analysis with 108 atoms/cm2 detection limits is needed, perform VPD/ICPeMS.
l If elemental particle analysis is required, perform AES or TOFeSIMS.
Energy dispersive X-ray analysis (EDS) may be used, but be aware that for small particles (<5 mm diameter), the majority of the analytical signal is coming... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Availability of certified standard materials, if required, must be addressed.
2. Sample Collection and Storage: Appropriate sampling times and methods of collection must be determined. Collection protocols and sample storage issues must be considered.
3. Sample Preparation: This stage must be considered carefully wit... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
## 13.2 Inorganic Contamination Analysis Techniques 13.2.1 Vapor Phase Decomposition
Vapor phase decomposition is a technique that provides high sensitivity, full wafer analysis. The VPD process is accomplished by exposing an unpatterned silicon wafer (with a native or other oxide layer on the surface) to HF vapor in ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Once prepared, the liquid sample is analyzed by instrumental techniques for qualitative identification and quantitative analysis of contaminant originally present on the wafer surface. Sample preparation by VPD can be coupled with several different trace elemental analysis techniques, such as atomic absorption spectros... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Regardless of the scanner's configuration, there must be a mechanism for the quantitative and contamination-free transfer of the SCS droplet into a sample vial for subsequent instrumental analysis.
Recent changes and advancements in VPD equipment includes various equipment suppliers creating a higher degree of automat... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| Wafer Technique | Application | Advantages | Limitations ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| rapid analysis oxides and nitride films analyzed same as bare Si | | | ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| Analysis of entire wafer surface (partial sections may also be | More labor intensive than TXRF | | ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| Very high lateral (1000 A ) and ˚ depth resolution (<10 A ) | Low 107 | | ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| analysis | analysis spot density | for elemental species | ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Ultratrace Impurity Analysis of Wafer Surfaces Chapter j 13 707 TABLE 13.1-1 General Characteristics of Various Analytical Techniques Used to Analyze Contamination on the Surface of Si
## Waferdcont'D | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| Waferdcont'd Technique | Application | Advantages | Limitations ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| Fourier Transform Infrared Spectrometry (FTIR), Attenuated Total Reflection FTIR (ATReFTIR) | Analysis of FTIR | Provides information on chemical nature of organic species | Relatively high detection limits compared to TOF eSIMS or thermal desorption Well suited for larg... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
SECTION
j IV Analytical and Control Aspects | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| Energy Dispersive X-ray Analysis (EDS) | Elemental analysis | Rapid analysis easily combined | Large analytica... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
| analysis times than AES XPS unsuitable for ultratrace analysis due to high detection limits. Lateral resolution not as low as AES | | | ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Ultratrace Impurity Analysis of Wafer Surfaces Chapter j 13 operation of the VPD and an ICPeMS. This improvement also helps to reduce adventitious contamination and increase the throughput of the equipment as operators do not manually transport samples between the VPD and the ICPeMS
or take valuable time and resources ... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress | ||
Some manufacturers use various configurations of a Peltier device or chilled liquid flow to cool the wafer [7], thus allowing better condensation and collection of the gaseous HF on the SiO2 surface. Finally, the type of oxide plays an important role in the decomposition rate; native oxides and steam oxides decompose f... | text_only | 16_handbook-of-silicon-wafer-cleaning-technology-third-edition_compress |