Dataset Viewer
Auto-converted to Parquet Duplicate
id
stringlengths
16
16
source_id
stringlengths
12
12
domain
stringclasses
6 values
scenario
stringclasses
6 values
label
stringclasses
3 values
protocol
stringlengths
1.59k
3.69k
three_class_category
stringclasses
4 values
violated_constraint
stringclasses
14 values
violated_principle
stringlengths
0
55
why_invalid
stringlengths
0
641
minimal_fix
stringlengths
0
287
difficulty
stringclasses
3 values
surface_plausibility
stringclasses
1 value
severity
stringclasses
3 values
source_correct_protocol
stringclasses
1 value
what_changed
stringclasses
11 values
gold_0507_000004
034560ce0e55
IMU_motion
IMU_motion
fatal_violation
Protocol: IMU-Based Wearable Motion Data Collection for Activity Recognition. Objective: To collect synchronized motion data using a custom wearable system with two inertial measurement units for activity recognition and orientation-estimation validation. The protocol targets classification of six activities, includ...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content. The accelerometer bandwidth is set to 10 Hz, but the signal processing requires frequencies up to 20 Hz (low-pass filter cutoff at 20 Hz and features in the 10-20 Hz band). This bandwidth mismatch means the sensor cannot capture the necessary high-frequency componen...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000012
735250a8b05e
EEG_BCI
EEG_BCI
fatal_violation
Protocol: Concurrent EEG Acquisition for Motor Imagery Classification and P300 Detection. Objective: To acquire synchronized EEG data using wet gel EEG, dry EEG, and ear-EEG systems for motor imagery classification and P300 detection, retaining alpha, beta, and mu rhythms for motor imagery analysis and extracting P3...
Signal & Sampling
data_bandwidth
Communication bandwidth infeasibility
The required real-time raw data rate exceeds the practical sustained bandwidth of the communication link. Without compression, channel reduction, or local feature extraction, the data stream will suffer loss or excessive latency. In this sample, the problematic modification is: All systems will be time-synchronized via...
Reduce the transmitted data rate through local feature extraction, compression, channel reduction, or a lower sampling rate, or use a link with sufficient sustained bandwidth.
hard
high
fatal
gold_0507_000026
c7676440774e
sEMG_gesture
sEMG_gesture
fatal_violation
Protocol: Surface Electromyography Acquisition for Upper Arm Gesture Classification. Objective: To acquire surface electromyography signals from eight targeted upper arm muscles using wet gel Ag/AgCl electrodes and a high-density dry electrode array, and to classify five target gestures and the rest state using extr...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
anatomical_misplacement sEMG signals from upper arm muscles do not generate the target physiological signals for hand gestures; the classifier would fail to recognize gestures, resulting in accuracy near chance level (e.g., <20% for five gestures, far below the expected >95%). Fix: Place electrodes on forearm muscles t...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000033
fae92b42d874
radar_vital_signs
radar_vital_signs
valid
Protocol: FMCW Millimeter-Wave Radar Vital Sign Monitoring Objective: To monitor vital signs using FMCW millimeter-wave radar. Equipment: Texas Instruments IWR1443BOOST or equivalent 77-81 GHz FMCW radar module. The radar is configured with single transmit and three receive antennas (1Tx/3Rx) for angle estimation. Chir...
N/A
none
easy
high
none
gold_0507_000042
50172d3ff07d
IMU_motion
IMU_motion
valid
Protocol: IMU-Based Motion Capture and Activity Recognition Objective: To establish a validated method for capturing human motion and recognizing daily activities using inertial measurement units (IMUs). Equipment: 3x 9-axis IMUs (accelerometer ±16g, gyroscope ±2000 dps, magnetometer ±4900 µT) and 3x 6-axis IMUs (acc...
N/A
none
easy
high
none
gold_0507_000057
914dd67962a0
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG-Based Motor Imagery and P300 Classification Using Wet Gel, Dry, and Ear-EEG Systems. Objective: To acquire simultaneous EEG data from wet gel, dry electrode, and ear-EEG systems for classification of left hand, right hand, and foot motor imagery, and for P300 detection in a separate target/non-target t...
Signal & Sampling
snr_floor
Signal-to-noise floor violation
The target signal is too weak to be measured reliably under the stated acquisition chain. Without adequate amplification, shielding, or noise control, the signal remains below the practical noise floor. In this sample, the problematic modification is: The study will recruit 20 healthy, right-handed participants (age 18...
Add a low-noise preamplifier, proper shielding, grounding, and signal conditioning before digitization.
hard
high
fatal
gold_0507_000058
a96a98b00d23
IMU_motion
IMU_motion
fatal_violation
Protocol: IMU-Based Motion Capture and Activity Recognition Using 6-Axis and 9-Axis IMUs. Objective: To acquire motion data using a 6-axis MEMS IMU and a 9-axis IMU for orientation estimation, joint kinematics validation, and activity recognition across a dataset of 10 activities collected from 20 participants. Equ...
Signal & Sampling
data_bandwidth
Communication bandwidth infeasibility
The required real-time raw data rate exceeds the practical sustained bandwidth of the communication link. Without compression, channel reduction, or local feature extraction, the data stream will suffer loss or excessive latency. In this sample, the problematic modification is: Data were acquired using a 6-axis MEMS IM...
Reduce the transmitted data rate through local feature extraction, compression, channel reduction, or a lower sampling rate, or use a link with sufficient sustained bandwidth.
hard
high
fatal
gold_0507_000078
f4d56b051dd8
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG-Based Motor Imagery and P300 Detection Using a Hybrid Wet Gel, Dry, and Ear-EEG Montage. Objective: To acquire EEG data using a hybrid electrode montage for cue-based motor imagery classification involving left hand, right hand, and feet movements, and to elicit P300 responses using a separate auditory...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
anatomical_misplacement Placing EEG electrodes on the upper trapezius muscle instead of the scalp fails to capture brain signals necessary for motor imagery and P300 detection. The target physiological signals for EEG are generated by the brain, not skeletal muscles, making the data acquisition invalid and expected per...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000081
52ccefd13bec
PPG_BP
PPG_BP
valid
Protocol: Continuous Blood Pressure Estimation via PTT from Synchronized PPG and ECG Objective: To estimate continuous blood pressure using pulse transit time derived from synchronized photoplethysmography (PPG) and electrocardiography (ECG) signals. Equipment: A single-lead clinical ECG module (e.g., AD8232) with pr...
N/A
none
easy
high
none
gold_0507_000088
d0f22401c1fb
IMU_motion
IMU_motion
fatal_violation
Protocol: IMU-Based Wearable Motion Capture and Activity Recognition. Objective: To perform motion capture using a custom wearable system composed of 9-axis and 6-axis IMUs, and to classify standardized human activities from synchronized inertial sensor data. Equipment: The custom wearable system comprises three B...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content, specifically the Nyquist theorem requiring sampling rate to be at least twice the highest signal frequency. The LSM6DSOX is sampled at 50 Hz, giving a Nyquist frequency of 25 Hz, but the low-pass filter has a cutoff at 40 Hz, allowing frequencies up to 40 Hz to pass...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000091
e2f748c1a454
sEMG_gesture
sEMG_gesture
fatal_violation
Protocol: Surface Electromyography Recording from the Dominant Upper Arm for Static Hand Gesture Recognition. Objective: To record surface electromyography signals from the dominant upper arm of healthy adult participants and evaluate wet gel Ag/AgCl electrodes, dry stainless steel electrodes, and a high-density gri...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
anatomical_misplacement Placing sEMG electrodes on upper arm muscles (e.g., biceps brachii) does not generate physiological signals corresponding to hand gestures, as hand movements are primarily controlled by forearm muscles. This misplacement makes the reported classification accuracies (e.g., 94.2%) physically impos...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000098
2ec6f075288e
sEMG_gesture
sEMG_gesture
fatal_violation
Protocol: Surface Electromyography Acquisition for Electrode Performance Evaluation in Static Hand Gesture Recognition. Objective: To acquire surface electromyography signals using wet-gel Ag/AgCl electrodes and a dry stainless steel high-density electrode array, and to evaluate electrode performance for classificat...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem The sampling rate of 1000 Hz is less than twice the maximum signal frequency of 750 Hz (2 * 750 = 1500 Hz), causing aliasing and rendering the high-density sEMG data physically invalid for accurate signal reconstruction. Fix: Increase the sampling rate for the high-density system to at ...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000113
7792fa1b540f
throat_mic_speech
throat_mic_speech
valid
Protocol: Silent Speech Recognition Using Throat Microphone and IMU Objective: To perform silent speech recognition by capturing throat vibrations and jaw movements using a piezoelectric contact microphone and an inertial measurement unit (IMU). Equipment: Throat Microphone: A piezoelectric contact microphone (e.g., Th...
N/A
none
easy
high
none
gold_0507_000124
7a8bdb24a2d2
sEMG_gesture
sEMG_gesture
valid
Protocol: sEMG-Based Hand Gesture Recognition Benchmark Objective: To establish a benchmark for classifying 10 distinct hand gestures using surface electromyography (sEMG), aiming for a mean classification accuracy of 95.0 ± 2.5%. Equipment: A 16-channel clinical-grade surface electromyography (sEMG) acquisition system...
N/A
none
easy
high
none
gold_0507_000125
786f091585f1
radar_vital_signs
radar_vital_signs
fatal_violation
Protocol: Multi-Band FMCW Radar Monitoring for Non-Contact Vital Sign Estimation Objective: Assess non-contact vital sign monitoring performance across millimeter-wave radar bands using three FMCW radar modules and reference physiological recordings. Equipment: The experimental setup will use three frequency-modul...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content. The sampling rate of 0.002 MSPS (2 Hz) is below the Nyquist rate for the heart rate signal up to 2 Hz, which requires at least 4 Hz sampling to avoid aliasing, rendering vital sign measurements invalid. Fix: Increase the sampling rate of the 24GHz radar to at least ...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000128
e5441b31828d
throat_mic_speech
throat_mic_speech
valid
Protocol: Silent Speech Recognition Using Throat Microphone and IMU Objective: To develop and validate a silent speech recognition system by fusing signals from a throat microphone and an inertial measurement unit (IMU), targeting applications in assistive communication. Equipment: Throat Microphone: Piezoelectric co...
N/A
none
easy
high
none
gold_0507_000138
30ed82df6710
EEG_BCI
EEG_BCI
fatal_violation
Protocol: Concurrent EEG Sensor Technology Comparison for Motor Imagery BCI and P300 Detection Objective: Acquire EEG data using three concurrent systems to compare wet gel, dry electrode, and ear-EEG sensor technologies during a cue-based motor imagery BCI paradigm and a separate P300 oddball task. Equipment: EEG...
Physical / Hardware
accuracy_impossibility
Unrealistic performance claim
The stated performance exceeds the physical and statistical limits of the sensing modality. Sensor noise, calibration uncertainty, physiological variability, and reference-device error prevent the claimed precision. In this sample, the problematic modification is: A 32-channel dry electrode system (Cognionics Mobile 12...
Replace the unrealistic accuracy claim with a physically plausible performance target and include calibration, uncertainty, and reference-device error in validation.
hard
high
fatal
gold_0507_000139
50172d3ff07d
IMU_motion
IMU_motion
valid
Protocol: IMU-Based Motion Capture for Upper and Lower Limb Activity Recognition Objective: To capture and classify human movement using 6-axis and 9-axis Inertial Measurement Units (IMUs) for robust activity recognition. Equipment: Four 6-axis IMUs (accelerometer ±16g, gyroscope ±2000 dps), two 9-axis IMUs (adding mag...
N/A
none
easy
high
none
gold_0507_000147
a9721bc62913
radar_vital_signs
radar_vital_signs
fatal_violation
Protocol: Multi-Frequency FMCW Radar Evaluation for Non-Contact Vital Sign Monitoring Objective: Evaluate three commercially available FMCW radar modules for non-contact respiration rate and heart rate monitoring, using simultaneous clinical reference measurements for validation. Equipment: Three commercially avai...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content. The NI 6008 data acquisition card has a bandwidth of approximately 5 kHz, but the radar's IF signal frequencies are at least 10 kHz for the AWR1642 radar and up to 40 kHz for the IWR1443, so the card cannot capture the signal accurately, making the experiment physic...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000168
066e856393c6
IMU_motion
IMU_motion
valid
Protocol: IMU-Based Motion Capture and Activity Recognition Benchmark Objective: To benchmark an IMU-based system for motion capture and activity recognition using specified hardware and procedures. Equipment: The system uses a 9-axis IMU module with an accelerometer (±16g range, 16-bit resolution, 1000 Hz max output...
N/A
none
easy
high
none
gold_0507_000170
a968fc9373f4
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG Recording for Motor Imagery and P300 BCI Tasks Using Wet, Dry, and Ear-EEG Systems Objective: Acquire EEG signals using wet gel, dry electrode, and ear-EEG systems to evaluate left/right hand motor imagery classification and P300 speller performance. Equipment: EEG signals will be acquired using a Bi...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
Anatomical misplacement: sensors must be placed on anatomy that generates the target physiological signal. Motor imagery signals are primarily generated in the sensorimotor cortex (central regions C3, C4, Cz), not the occipital cortex (O1, O2). Placing electrodes on O1 and O2 would capture visual-related activity, not ...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000177
0fe2e8c6d897
radar_vital_signs
radar_vital_signs
fatal_violation
Protocol: 77 GHz FMCW Millimeter-Wave Radar for Non-Contact Vital Sign Monitoring Objective: Monitor respiration rate and heart rate using a 77 GHz FMCW millimeter-wave radar sensor and validate radar-derived estimates against simultaneous ECG and respiratory belt reference signals. Testing the system's tolerance to...
Physical / Hardware
temperature_range
Operating temperature violation
The protocol requires the electronics to operate outside their rated temperature range. Under those conditions, sensor accuracy, oscillator stability, battery behavior, and circuit reliability cannot be assumed. In this sample, the problematic modification is: Vital sign monitoring was performed using a 77GHz FMCW mill...
Restrict the experiment to the rated component temperature range or use components rated and validated for the claimed environment.
hard
high
fatal
gold_0507_000180
ac2386220b65
IMU_motion
IMU_motion
valid
Protocol: IMU-Based Motion Capture and Activity Recognition Benchmark Objective: To benchmark the accuracy of IMU-based motion capture and activity recognition against ground truth systems. Equipment: Six Bosch BNO055 9-axis IMU modules (3-axis accelerometer, gyroscope, magnetometer) with integrated sensor fusion. Modu...
N/A
none
easy
high
none
gold_0507_000188
7663f4ec570f
radar_vital_signs
radar_vital_signs
fatal_violation
Protocol: Multi-Frequency FMCW Radar Monitoring for Non-Contact Vital Sign Estimation Objective: Evaluate non-contact respiration rate and heart rate estimation using three frequency-modulated continuous wave radar modules operating at 24 GHz, 60 GHz, and 77 GHz. Equipment: The experimental setup will use three FM...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. For the 77 GHz radar system with a 4 GHz bandwidth and chirp duration of 1 ms (from 1 kHz chirp repetition), the maximum intermediate frequency is approximately 53.33 kHz, which exceeds the Nyquist frequency of 50 kHz f...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000189
7321638af989
EEG_BCI
EEG_BCI
valid
Protocol: EEG-BCI Motor Imagery Classification Protocol Objective: To classify kinesthetic motor imagery of left hand, right hand, and feet movements using an EEG-based brain-computer interface. Equipment: Use a research-grade EEG system (e.g., g.tec g.USBamp) with 16 active Ag/AgCl electrodes. Place electrodes accordi...
N/A
none
easy
high
none
gold_0507_000191
ba24a41d00d9
sEMG_gesture
sEMG_gesture
fatal_violation
Protocol: Surface Electromyography Recording for Static Leg Gesture Classification Objective: Record surface electromyography signals from the dominant forearm of 10 healthy participants during six static leg gestures and compare classification performance across three sensor configurations. Equipment: The study w...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
anatomical_misplacement sEMG sensors placed on forearm muscles cannot generate physiological signals for leg gestures, as leg movements are controlled by leg muscles (e.g., quadriceps, hamstrings), not forearm muscles, making the experiment physically invalid. Fix: Either change the sensor placement to appropriate leg ...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000206
2f956bb4792c
throat_mic_speech
throat_mic_speech
fatal_violation
Protocol: Silent Speech Recognition Using a Contact Microphone and IMU Objective: Acquire synchronized contact microphone and IMU signals from five healthy participants during silent articulation, and classify silent utterances from a 100-word vocabulary using combined acoustic and laryngeal kinematic features. Equ...
Signal & Sampling
adc_resolution
ADC resolution limitation
The ADC resolution is too coarse for the expected signal amplitude. The quantization step can exceed meaningful physiological signal variations, preventing reliable measurement. In this sample, the problematic modification is: Data was collected from five healthy participants (3 male, 2 female; age 25-35)..
Use a higher-resolution ADC and, where needed, an analog front-end with appropriate gain so that the expected low-amplitude signal can be resolved.
hard
high
fatal
gold_0507_000212
aac54599607d
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous Blood Pressure Estimation Using Wearable PPG and ECG Sensors Objective: Estimate continuous blood pressure using a custom wearable device integrating photoplethysmography and electrocardiography sensors, with pulse transit time converted to blood pressure through subject-specific calibration. E...
Perception & Anatomy
optical_obstruction
Optical signal-path obstruction
PPG relies on light transmission/reflection; opaque obstacles block optical path. Stainless steel is opaque to green (525 nm) and infrared (940 nm) light, completely blocking the optical path, so no PPG signal can be acquired, rendering PTT calculation and BP estimation impossible as per the protocol's reliance on PPG ...
Remove the opaque barrier and ensure direct optical coupling between the PPG emitter/detector and the skin.
easy
high
fatal
gold_0507_000241
56c4e21f404a
PPG_BP
PPG_BP
valid
Protocol: Continuous blood pressure tracking using synchronized photoplethysmography (PPG) and electrocardiography (ECG) to derive pulse transit time (PTT) for beat-to-beat estimation. Objective: To continuously estimate systolic (SBP) and diastolic blood pressure (DBP) from PTT derived from ECG and PPG signals. Eq...
N/A
none
easy
high
none
gold_0507_000244
a062adbf629b
throat_mic_speech
throat_mic_speech
valid
Protocol: Silent Speech Recognition via Throat Microphone and Inertial Measurement Unit (IMU) Objective: To develop a benchmark dataset for silent speech recognition by capturing sub-vocalized speech using a throat microphone and accompanying head movement data via an IMU. Equipment: A commercially available piezoele...
N/A
none
easy
high
none
gold_0507_000246
0c975e3e3a7b
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG Recording for Motor Imagery and P300 Detection Using Wet, Dry, and Ear-EEG Systems Objective: Acquire EEG data using wet gel, dry electrode, and ear-EEG systems to evaluate three-class motor imagery classification and binary P300 detection. Equipment: EEG data will be acquired using three electrode s...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
anatomical_misplacement Motor imagery generates mu (8–12 Hz) and beta (13–30 Hz) rhythms primarily in the sensorimotor cortex (C3, Cz, C4). Applying CSP to parietal electrodes (Pz, POz) would not capture these rhythms, making feature extraction and classification physically impossible as the target physiological signal...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000248
e8e1c7343fe6
throat_mic_speech
throat_mic_speech
fatal_violation
Protocol: Multimodal Silent Speech Interface via Contact Microphone and Inertial Measurement Unit Fusion Objective: To construct and evaluate a silent speech interface system that captures subvocalization signals and laryngeal/jaw kinematics to achieve sequence recognition with a target word error rate (WER) of <15% a...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content. The IMU sampling rate of 10 Hz results in a Nyquist frequency of 5 Hz, which is lower than the 20 Hz low-pass filter cutoff, causing aliasing and making accurate signal reconstruction impossible. Fix: Increase the IMU sampling rate to at least 40 Hz to satisfy the N...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000252
c33bb72d9ec1
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG data will be acquired using a g.tec g.USBamp amplifier connected to wet, dry, and ear-EEG electrodes during a cue-based motor imagery paradigm and a separate P300 detection pipeline. Objective: The objective is to record EEG signals for motor imagery classification and P300 detection, compare performan...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
anatomical_misplacement: Sensor must be placed on anatomy that generates the target physiological signal. EEG signals are generated by brain activity and require electrode placement on the scalp or near the head (e.g., concha for ear-EEG). Placing electrodes on the wrist, which is a limb, will not capture EEG signals, ...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000259
142104d1965d
sEMG_gesture
sEMG_gesture
valid
Protocol: sEMG-Based Hand Gesture Recognition Benchmark Objective: To benchmark a sEMG-based hand gesture recognition system using a standardized experimental protocol. Equipment: A 16-channel wireless sEMG system (e.g., Delsys Trigno Avanti) with Ag/AgCl dry electrodes will be used. The system has a bandwidth of 20-45...
N/A
none
easy
high
none
gold_0507_000260
50f2a1204559
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous Blood Pressure Tracking Using PPG and ECG. Objective: To perform continuous blood pressure tracking using photoplethysmography and electrocardiography signals by extracting pulse wave features, ECG R-peaks, PTT, and PWV for blood pressure estimation. Equipment: PPG signals will be acquired usi...
Physical / Hardware
power_budget
Power budget infeasibility
The claimed runtime or operating mode is inconsistent with the energy available from the stated power source. The device cannot sustain the described sensing, processing, and communication workload for the claimed duration. In this sample, the problematic modification is: First, the user wants me to generate a detailed...
Revise the battery capacity, duty cycle, sampling rate, processing load, or runtime claim so that total energy consumption fits within the stated power budget.
hard
high
fatal
gold_0507_000261
5857d65bd040
IMU_motion
IMU_motion
fatal_violation
Protocol: Motion data were captured using two IMU systems and validated against an optical motion capture system during standardized activity trials. Objective: The objective is to acquire motion data for activity classification and joint-angle estimation, compare IMU-derived kinematic outputs against optical motion...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content. The accelerometer bandwidth of 0-10 Hz is insufficient to capture frequency components above 10 Hz, such as those in walking and running (which typically have content up to 20-30 Hz), resulting in loss of critical signal data and invalid kinematic measurements. Fix:...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000264
a0ece592e15f
EEG_BCI
EEG_BCI
fatal_violation
Protocol: Multi-Modal EEG Recording for Motor Imagery Classification Objective: Acquire EEG signals using wet gel, dry headband, and in-ear EEG sensors to evaluate cue-based motor imagery classification across separate and fused electrode modalities. Equipment: EEG signals will be acquired using three electrode ty...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be >= 2x the maximum signal frequency. The hardware bandpass filter limits the signal to a maximum frequency of 100 Hz, requiring a sampling rate of at least 200 Hz to avoid aliasing. With a sampling rate of 120 Hz, which is below 200 Hz, the experiment violates the ...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000267
a53c5bb3881e
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG-Based Motor Imagery and P300 Classification Using Wet Gel, Dry, and Ear-EEG Systems Objective: Acquire EEG data using wet gel, dry electrode, and ear-EEG systems to evaluate three-class motor imagery classification and binary P300 detection. Equipment: EEG data will be acquired using three electrode ...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. The sampling rate of 64 Hz results in a Nyquist frequency of 32 Hz, which is less than the maximum signal frequency of 40 Hz from the bandpass filter, causing aliasing and invalidating data for frequencies above 32 Hz. ...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000277
15e9d586cb3d
throat_mic_speech
throat_mic_speech
fatal_violation
Protocol: Silent Speech Recognition Using a Contact Microphone and IMU Objective: Acquire subvocalization vibration and laryngeal movement signals from healthy adult participants to perform silent speech recognition on a 100-word vocabulary. Equipment: Data will be collected from healthy adult participants seated ...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content. The microphone has a bandwidth of 50-500 Hz, but the bandpass filter requires frequencies up to 4000 Hz to isolate speech-related vibrations, so frequencies above 500 Hz cannot be captured, making the experiment physically impossible. Fix: Use a microphone with a fr...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000282
41543f72923a
IMU_motion
IMU_motion
fatal_violation
Protocol: Wearable IMU-Based Daily Activity Recognition Objective: Collect motion data from ten healthy adult participants performing daily activities, process inertial signals from five wireless IMU nodes, and classify sitting, standing, walking, and stair climbing. Equipment: Motion data will be collected from t...
Physical / Hardware
temperature_range
Operating temperature violation
The protocol requires the electronics to operate outside their rated temperature range. Under those conditions, sensor accuracy, oscillator stability, battery behavior, and circuit reliability cannot be assumed. In this sample, the problematic modification is: Motion data were collected from ten healthy adult participa...
Restrict the experiment to the rated component temperature range or use components rated and validated for the claimed environment.
hard
high
fatal
gold_0507_000296
d3a9a880386f
throat_mic_speech
throat_mic_speech
valid
Protocol: Silent Speech Recognition via Throat Microphone and Inertial Measurement Unit (IMU) Objective: To develop a silent speech interface by capturing subvocalization-induced laryngeal vibrations and associated neck movements using a contact microphone and IMU, enabling the classification of a predefined vocabular...
N/A
none
easy
high
none
gold_0507_000302
212e01d08e0b
sEMG_gesture
sEMG_gesture
fatal_violation
Protocol: Surface Electromyography (sEMG) Recording and Hand Gesture Classification Using Multiple Electrode Types Objective: Acquire sEMG signals from the dominant forearm during 10 distinct hand gestures and compare classification performance across three electrode types: wet gel, dry, and high-density arrays. Eq...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. The bandpass filter limits the signal to a maximum frequency of 450 Hz, requiring a sampling rate of at least 900 Hz (2 * 450 Hz). The sampling rate of 800 Hz is below this threshold, leading to aliasing and invalidatin...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000317
91be97494458
throat_mic_speech
throat_mic_speech
fatal_violation
Protocol: Subvocalized speech signals were recorded using a wearable device integrating a MEMS contact microphone and a 9-axis IMU, with audio and motion features fused for word-level classification. Objective: The objective is to recognize silent speech from a 100-word vocabulary by combining audio features from a ...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content. The microphone bandwidth (50 Hz - 2 kHz) does not cover the upper frequency limit of the bandpass filter (4000 Hz), so frequencies above 2 kHz are not captured, leading to incomplete audio features and invalid MFCC extraction for speech signals. Fix: Use a microphon...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000325
50f2a1204559
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous blood pressure was estimated non-invasively using pulse transit time derived from synchronized ECG and PPG signals, with beat-to-beat BP compared against invasive arterial measurements during rest and mild exercise. Objective: The objective is to continuously monitor systolic and diastolic blood...
Physical / Hardware
power_budget
Power budget infeasibility
The claimed runtime or operating mode is inconsistent with the energy available from the stated power source. The device cannot sustain the described sensing, processing, and communication workload for the claimed duration. In this sample, the problematic modification is: Continuous blood pressure (BP) was estimated no...
Revise the battery capacity, duty cycle, sampling rate, processing load, or runtime claim so that total energy consumption fits within the stated power budget.
hard
high
fatal
gold_0507_000330
94af7bc3db78
IMU_motion
IMU_motion
fatal_violation
Protocol: Motion data were recorded using a wearable sensor node integrating a 6-axis IMU and a 9-axis IMU. The data were processed to estimate segment orientation, compensate for gravity, and classify common daily activities, with validation against an optical motion capture system. Objective: The objective is to a...
Physical / Hardware
accuracy_impossibility
Unrealistic performance claim
The stated performance exceeds the physical and statistical limits of the sensing modality. Sensor noise, calibration uncertainty, physiological variability, and reference-device error prevent the claimed precision. In this sample, the problematic modification is: Data were collected using a custom wearable sensor node...
Replace the unrealistic accuracy claim with a physically plausible performance target and include calibration, uncertainty, and reference-device error in validation.
hard
high
fatal
gold_0507_000338
8ac99e5395b7
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous blood pressure was tracked non-invasively using synchronized photoplethysmography and electrocardiography, with beat-to-beat BP estimated from pulse transit time and validated against a non-invasive reference device. Objective: The objective is to continuously estimate systolic and diastolic blo...
Perception & Anatomy
optical_obstruction
Optical signal-path obstruction
optical_obstruction: PPG relies on light transmission/reflection; opaque obstacles block optical path. The opaque tape blocks the 530 nm green LED light from the PPG sensor, preventing light penetration and reflection from the skin, which is essential for PPG signal acquisition. This makes it physically impossible to o...
Remove the opaque barrier and ensure direct optical coupling between the PPG emitter/detector and the skin.
easy
high
fatal
gold_0507_000342
914dd67962a0
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG data were recorded using a hybrid 16-channel system combining wet gel, dry, and ear-EEG electrodes for motor imagery and P300 speller tasks. Data were processed to extract CSP and ERP features for classification and evaluated using cross-validation. Objective: The objective is to classify motor imagery...
Signal & Sampling
snr_floor
Signal-to-noise floor violation
The target signal is too weak to be measured reliably under the stated acquisition chain. Without adequate amplification, shielding, or noise control, the signal remains below the practical noise floor. In this sample, the problematic modification is: EEG data were acquired using a 16-channel g.tec g.USBamp biosignal (...
Add a low-noise preamplifier, proper shielding, grounding, and signal conditioning before digitization.
hard
high
fatal
gold_0507_000354
50172d3ff07d
IMU_motion
IMU_motion
valid
Protocol: IMU-Based Motion Capture and Activity Recognition Objective: To acquire and process inertial data from wearable IMUs for the classification of daily living activities. Equipment: Two wireless 9-axis IMU units (e.g., Xsens MTw or equivalent). Each unit contains a tri-axial accelerometer (range: ±16g), gyroscop...
N/A
none
easy
high
none
gold_0507_000357
50f2a1204559
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous Blood Pressure Tracking Using PPG and ECG. Objective: To estimate continuous blood pressure using synchronized photoplethysmography and electrocardiography signals by extracting pulse wave features, ECG R-peaks, PTT, and PWV. Equipment: PPG signals will be captured with a custom sensor array i...
Physical / Hardware
power_budget
Power budget infeasibility
The claimed runtime or operating mode is inconsistent with the energy available from the stated power source. The device cannot sustain the described sensing, processing, and communication workload for the claimed duration. In this sample, the problematic modification is: First, the user wants a detailed experimental p...
Revise the battery capacity, duty cycle, sampling rate, processing load, or runtime claim so that total energy consumption fits within the stated power budget.
hard
high
fatal
gold_0507_000358
85892f2adcf9
radar_vital_signs
radar_vital_signs
fatal_violation
Protocol: FMCW Radar-Based Vital Sign Monitoring Objective: To non-invasively measure respiration rate (RR) and heart rate (HR) using three frequency-modulated continuous-wave (FMCW) radar modules at 24, 60, and 77 GHz, and to validate the measurements against clinical reference devices. Equipment: 24 GHz radar: I...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be >= 2x the maximum signal frequency. The sampling rate of 5 kSPS is less than twice the maximum IF frequency of 8 kHz for the 60 GHz and 77 GHz radars, leading to aliasing and invalid data acquisition. Fix: Increase the sampling rate to at least 16 kSPS, such as re...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000380
da2690e12c13
EEG_BCI
EEG_BCI
valid
Protocol: EEG-Based Motor Imagery BCI Benchmark Objective: To establish a standardized benchmark for classifying left-hand versus right-hand motor imagery using an EEG-based brain-computer interface. Equipment: A research-grade, active electrode EEG system (e.g., g.tec g.USBamp or BioSemi ActiveTwo) with a minimum of 1...
N/A
none
easy
high
none
gold_0507_000381
2d848673c0b2
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous blood pressure (BP) estimation was performed using a custom wearable sensor integrating photoplethysmography (PPG) and electrocardiography (ECG). Participants underwent rest and mild exercise protocols while simultaneous reference BP measurements were collected. Pulse transit time (PTT) and pulse ...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. The ECG signal is bandpass filtered to 0.5–40 Hz, so the maximum frequency is 40 Hz. The required sampling rate is at least 80 Hz, but the protocol uses 70 Hz, which is insufficient and will cause aliasing, invalidating...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000393
8d8218292f48
PPG_BP
PPG_BP
valid
Protocol: Continuous Blood Pressure Estimation via PPG and ECG Pulse Wave Analysis Objective: To develop and validate a continuous blood pressure estimation method using photoplethysmography (PPG) and electrocardiography (ECG) pulse wave analysis in healthy adults. Equipment: A reflective, wrist-worn PPG sensor with ...
N/A
none
easy
high
none
End of preview. Expand in Data Studio

PhysDox

Benchmark for physical feasibility auditing of physiological sensing protocols. Paper: PhysDox (Findings of EMNLP 2026). Code: github.com/phish-tech/PhysDox.

What is in this repository

Path Content
silver/physdox_silver_5000.json Silver set, 5,000 protocols, all labels and annotations
gold_dev/physdox_gold_dev_100.json 100 Gold items with labels, drawn from the 683-item Gold set
experiment_outputs/.../<run>/ summary.json, confusion matrices, three-class analysis for all 48 runs
experiment_outputs/.../silver5k_*/per_item_results.jsonl Per-item model outputs for the 24 Silver runs
experiment_outputs/.../tables/ Paper result tables (md, csv, xlsx)
manifest.json Size and SHA-256 of every file

The full Gold set (683 items) and the per-item outputs of the 24 Gold runs contain Gold labels. They are in the gated repository phishphish/PhysDox-Gold.

Task

Given a protocol, the model does two things.

  1. Stage 1. Classify it as valid, minor_issue, or fatal_violation.
  2. Stage 2. For a fatal protocol, name the violated constraint, either one of 3 coarse categories or one of 12 fine-grained constraints.

Fields

Field Meaning
id Item id
domain One of EEG_BCI, PPG_BP, IMU_motion, radar_vital_signs, sEMG_gesture, throat_mic_speech
scenario Short description of the sensing task
protocol The protocol text shown to the model
label valid, minor_issue, or fatal_violation
violated_constraint One of 12 fine constraints, suboptimal for minor issues, none for valid items
three_class_category Signal & Sampling, Perception & Anatomy, or Physical / Hardware (Gold)
violated_principle, why_invalid, minimal_fix Explanation of the error and the smallest fix
difficulty, surface_plausibility, severity Annotation metadata
source_correct_protocol, what_changed The valid counterpart and the edit that introduced the error, where available

Silver items also carry an error_category field from the generation pipeline.

Statistics

Silver Gold
Items 5,000 683
valid / minor / fatal 1,500 / 1,250 / 2,250 232 / 74 / 377
Fine constraints 12, about 187 each 12 plus suboptimal

Silver was built by human-machine cooperation with humans in the loop and passed rule-based and quality filtering. Gold was authored, annotated, and cross-validated by domain experts. Silver is a development and scale benchmark. Report Gold results for claims about real-world feasibility auditing.

Reproducing the paper numbers

Use the code repository. scripts/audit_experiments.py and scripts/export_main_results_table.py rebuild the tables from the files here, plus the gated Gold outputs for the Gold columns.

Limitations and intended use

  • Silver is partly machine-generated and may contain stylistic regularities. Check the paper before drawing real-world conclusions from Silver alone.
  • The data cover six sensing domains and English text only.
  • The protocols are for evaluating models. They are not guidance for conducting experiments on people.
  • Do not use Gold items, including the dev subset, to train models you then report on PhysDox.

Citation

@inproceedings{liu-etal-2026-physdox,
    title = "{P}hys{D}ox: Benchmarking {LLM}s on Physical Feasibility Auditing of Physiological {S}ensing Protocols",
    author = "Liu, He  and Gu, Boyuan  and Cheng, Shuaiqi  and Sun, Haiyang  and You, Siyu  and Hu, Xuming",
    booktitle = "Findings of the {A}ssociation for {C}omputational {L}inguistics: {EMNLP} 2026",
    year = "2026",
    address = "Budapest, Hungary",
    publisher = "Association for Computational Linguistics",
    url = "https://aclanthology.org/2026.findings-emnlp.264/",
    doi = "10.18653/2026.findings-emnlp.264",
    pages = "5539--5560",
}
Downloads last month
66