| # Inference contract | |
| `engine` exposes `inspect(path)`, `classify(paths, progress=None)`, | |
| `infer(left_paths, right_paths, progress=None)`, and `status()`. | |
| The progress callback receives `(stage: str, detail: dict)`; detail includes | |
| `fraction`, `current`, and `total` when the amount of work is known. | |
| Importing the API and calling `status()` neither downloads nor loads a model. | |
| ## Provenance and loading | |
| The source is `MesserMMP/coronary-syntax-prediction` at the immutable revision | |
| in `manifest.json`. Ten complete R3D-18 + projected-LSTM checkpoints are used: | |
| five left and five right models, paired by fold. The artery classifier is a | |
| separate R3D-18. Safetensors are loaded strictly, after verifying their SHA-256 | |
| hash and expected size. Calibration is fetched from the same revision and | |
| its checksum and coefficients are also verified. No legacy pickle checkpoints, | |
| secondary weights repository, randomly initialized fallback, or incomplete | |
| ensemble is used. | |
| Set `SYNTAX_MODEL_CACHE` to a directory whose relative paths match the model | |
| repository. Missing files are fetched on demand. Set `SYNTAX_DEVICE=cpu` | |
| (default) or `cuda` on a compatible machine; `SYNTAX_CPU_THREADS` defaults to 2. | |
| Models run sequentially in float32 and are released after use. Only one | |
| projection's backbone activations are retained at a time, followed by the | |
| original LSTM over the ordered features. | |
| ## Input and preprocessing | |
| The supported input is an unsigned 8-bit or 16-bit, single-channel DICOM cine | |
| with 10–1024 frames and at most 512 MiB of decoded pixels. DICOM header | |
| dimensions must match the pixels. StudyInstanceUID and SOPInstanceUID must be | |
| retained. Mixed-study inputs and repeated SOPInstanceUIDs are rejected. Source | |
| files are read without modification. Returned metadata excludes patient names, | |
| patient identifiers, dates, institution names, and free-text DICOM fields. | |
| The score transform matches `full_model/rnn_dataset.py`: uint16 is scaled by | |
| the maximum value of the entire sequence to uint8; shorter-than-32-frame clips | |
| are doubled repeatedly, then the central 32 frames are selected. Grayscale is | |
| replicated into RGB, scaled to [0, 1], bilinearly resized to 256×256 with | |
| antialiasing, and normalized with ImageNet mean and standard deviation. | |
| Windowing, rescale, and MONOCHROME1 inversion are not applied because the | |
| published pipeline reads `pixel_array` directly. Unsupported signed, color, | |
| or single-frame input is rejected instead of being silently reinterpreted. | |
| Within each artery, input order is retained exactly. The LSTM is | |
| order-sensitive, so filename sorting would change predictions. To reproduce | |
| an evaluation study, pass the paths in `videos_left` and `videos_right` order. | |
| ## Artery assignment | |
| The classifier uses all original frames, RGB grayscale at 224×224, bilinear | |
| tensor resizing with `antialias=False`, and ImageNet normalization. | |
| `probability_right` is sigmoid of its one output: | |
| left is ≤0.1, right is ≥0.9, and values between these thresholds are unassigned | |
| in the engine output. The service automatically excludes these uncertain | |
| projections from scoring. This is artery probability, not confidence in a | |
| SYNTAX estimate. Only classifier-determined left/right lists reach `infer`; | |
| users cannot override assignments or projection order. | |
| The antialias setting is explicit because torchvision changed its unspecified | |
| default in version 0.17. The archived Philips probabilities are reproduced by | |
| `False`; the recently repaired Siemens examples were classified with `True`. | |
| All artery groups in the two verification studies agree under both settings, | |
| but their probabilities differ. This does not guarantee identical grouping for | |
| every possible input. Published examples cache verified GPU classifier outputs | |
| and ensemble results computed with those assignments. The score model separately uses | |
| `antialias=True`, as explicitly specified by its reference inference code. | |
| See the [official Resize documentation](https://docs.pytorch.org/vision/0.21/generated/torchvision.transforms.Resize.html). | |
| For long sequences, classifier convolution uses temporal tiles with 56-frame | |
| context on either side, aligned to the final temporal stride of 8. R3D-18 has | |
| a 109-frame temporal receptive field. Disjoint final feature positions are | |
| averaged once, so all original frames contribute without subsampling. Minor | |
| floating-point differences relative to one large batch are expected. | |
| ## Scores and calibration | |
| Each artery model's second output is log(1 + artery SYNTAX). Its score is | |
| `float(torch.exp(output)) - 1`. The first output is an artery-specific binary | |
| logit and is not exposed as a total disease probability. | |
| For fold i, calculate `raw_i = left_i + right_i` and | |
| `calibrated_i = a_i * raw_i + b_i`. Average each of those five values, then | |
| clip only the final study score at zero. Do not clip artery/fold intermediate | |
| values, apply calibration separately to arteries, or calibrate an ensemble | |
| mean with averaged coefficients. The returned `per_fold` values preserve the | |
| unclipped intermediates for reproducibility. | |
| If a side is absent, its score is `null` and both study totals are `null` with | |
| `complete=false`. The present side can still be inspected. The original batch | |
| evaluation represented missing sides by zero; this interactive service instead | |
| makes incompleteness explicit, because absence of an artery view does not show | |
| that the artery has no disease. | |
| ## Validation | |
| Run `python -m unittest engine.test_engine -v` for offline transform, tiling, | |
| architecture, calibration, and checkpoint-integrity checks. | |
| `python -m engine.validate_reference --help` describes the optional real-data | |
| check. It compares explicit JSON grouping/order to archived evaluation results, | |
| and can execute the original source model and dataset on CPU for an independent | |
| batched comparison. It does not download or alter input studies. | |