πŸ‘οΈ RetinaFlow

Dual-Model Retinal Disease Classifier β€” ResNet-50 & EfficientNet-B5, trained on a severely imbalanced 11.8K-image clinical dataset, augmented with OT-CFM (Flow Matching) synthetic generation.

Python Framework UI Status License

⚠️ This is a research/educational project, not a certified medical device. It is not intended for clinical use, diagnosis, or treatment decisions. See Disclaimer.


πŸ“– Table of Contents


πŸ”¬ Overview

RetinaFlow is an end-to-end deep learning pipeline that classifies retinal fundus photographs into 8 diagnostic categories:

AMD Β· Cataract Β· Diabetic Retinopathy Β· Glaucoma Β· Hypertension Β· Myopia Β· Normal Β· Others

Rather than presenting a single "best" model and hiding its weaknesses, this project documents a complete, honest experimentation log β€” every architecture tried, every bug found and fixed, every hypothesis tested and killed β€” and ships two champion models side by side, letting the end user choose the trade-off that matters for their use case:

Optimizes for Best for
πŸ† M5a β€” ResNet-50 Overall diagnostic accuracy General-purpose screening
🎯 M6 β€” EfficientNet-B5 Minority-class sensitivity Not missing rare, high-risk cases

βš–οΈ The Core Challenge: Extreme Class Imbalance

The real obstacle in this project was never "build a classifier" β€” it was severe class skew. A model that blindly predicts Normal or Diabetic Retinopathy for everything already scores ~74% accuracy while being clinically useless.

Class Train Pool Test Set Imbalance Ratio (vs. Normal)
Normal 4,698 705 1.0Γ—
Diabetic Retinopathy 4,113 617 1.1Γ—
Others 1,102 165 4.3Γ—
Glaucoma 930 140 5.1Γ—
Cataract 340 51 13.8Γ—
Myopia 294 44 16.0Γ—
AMD 274 41 17.1Γ—
Hypertension 88 13 53.4Γ—

Because Hypertension had only 88 real training images (and just 13 in the test set), Hypertension recall became this project's critical benchmark metric β€” and its statistical volatility (each misclassified image swings recall by ~7.7pp) is called out explicitly throughout the notebook rather than glossed over.


πŸ“Š Dataset

11,839 real fundus photographs, unified from 4 public clinical registries:

Source Registry Images Share
ODIR-5K 7,000 59.1%
APTOS-2019 3,484 29.4%
ACRIMA 705 6.0%
ORIGA 650 5.5%

All models are evaluated on the exact same strictly isolated, held-out, 100% real test set of 1,776 images β€” no model was ever tested on synthetic data, and every row in the results table below is directly comparable.


🧭 The Research Journey

The notebook (EyeDisease.ipynb, 122 cells) documents six model generations, each a response to a specific, diagnosed failure in the one before it:

flowchart TD
    M1["M1 β€” Scratch CNN\nPerformance floor"] --> M2["M2 β€” ResNet-50 Transfer\nSilent loss-weighting bug"]
    M2 --> M3["M3 β€” Sampler + Focal Loss\nOver-corrected, majority classes collapsed"]
    M3 --> AUDIT1["🧾 Section 19.0 Audit\nRoot-causes every prior bug"]
    AUDIT1 --> M4["M4 β€” OT-CFM Flow Matching\n+1,600 synthetic minority images"]
    M4 --> M5a["M5a β€” ResNet-50 Post-CFM\nπŸ† Champion #1"]
    M4 --> M5b["M5b β€” Swin-T\nHigher accuracy, worse Macro-F1"]
    M5a --> DIAG["πŸ”¬ Generative Recovery Investigation\nMode collapse confirmed, recovery attempted & abandoned"]
    DIAG --> M6["M6 β€” EfficientNet-B5\n🎯 Champion #2"]

Highlights along the way:

  • M1 (Scratch CNN): 92.3% Hypertension recall looked amazing β€” until you notice overall accuracy was 23%. A near-random model over-predicts rare classes by noise. Lesson: never read one metric in isolation.
  • M2 (ResNet-50): Accuracy jumped to 69%, but Hypertension recall collapsed to 7.7%. Root cause, found later in the Section 19.0 audit: the "weighted" loss silently ran as plain Cross-Entropy due to a variable-scoping bug (class_weights out of scope at runtime).
  • M3 (Sampler + Focal Loss): Stacking two independent imbalance-correction mechanisms at once over-corrected so hard that Normal-class recall dropped to 6.8%. Textbook double-correction failure.
  • Section 19.0 Audit: A full stop-and-diagnose pass before building anything else β€” it surfaced the M2 bug, the flawed val-loss checkpoint selection used in M1–M3, the M3 double-correction, and the lack of any quantitative synthetic-data quality check.
  • M4 (OT-CFM Flow Matching): A class-conditional Optimal Transport Conditional Flow Matching model generated 1,600 synthetic images for the 4 weakest classes (+600 Hypertension, +350 AMD, +350 Myopia, +300 Cataract).
  • Generative Recovery Investigation (19.1–19.5): A feature-space diversity audit using frozen ResNet-50 embeddings found ~30% mode collapse in the synthetic images. A targeted fine-tuning recovery attempt was tried, measured, and found inconclusive (one class even regressed) β€” so the generative-model recovery path was deliberately discontinued rather than chased indefinitely. This is documented as a clean, evidence-based stopping point, not a failure to hide.
  • M5b (Swin-T) vs. M5a (ResNet-50): The newer transformer architecture did not win β€” ResNet-50 generalized better on Macro-F1 and minority recall, a reminder that architecture novelty isn't automatically better without enough data to justify the extra capacity.
  • M6 (EfficientNet-B5): Built after correcting the checkpoint-selection and class-weighting bugs, explicitly optimized as the "catch rare cases" counterpart to M5a.

πŸ† Final Benchmark Results

All numbers below are from the same 1,776-image, 100%-real, held-out test set.

Model Accuracy Macro-F1 Weighted-F1 Hypertension Recall Verdict
M1 β€” Scratch CNN 23.37% 0.228 0.184 92.3% Near-random; high recall is a noise artifact
M2 β€” ResNet-50 (standard) 69.14% 0.534 0.669 7.7% Strong accuracy; silent bug collapsed minority recall
M3 β€” ResNet-50 (Sampler + Focal) 25.73% 0.298 0.257 69.2% Over-corrected; majority classes destroyed
M5a β€” ResNet-50 (Post-Flow-Matching) 71.68% 0.600 0.710 15.4% πŸ† Best overall β€” shipped as "General-Purpose"
M5b β€” Swin-T 72.24% 0.573 0.711 7.7% Higher raw accuracy, worse Macro-F1 & minority recall
M6 β€” EfficientNet-B5 62.61% 0.570 0.653 38.5% 🎯 Best minority sensitivity β€” shipped as "High-Sensitivity"

Note: Hypertension recall figures are computed on only 13 test images and carry high variance β€” a single misclassification shifts the number by ~7.7 percentage points. Treat these as directional, not precise.


πŸ› οΈ Key Technical Contributions

  • OT-CFM Flow Matching for medical data augmentation β€” a class-conditional Optimal Transport Conditional Flow Matching generative model (velocity-field estimator, trained to convergence at loss 0.0235) used to synthesize minority-class fundus images, rather than relying on GANs or classic geometric augmentation alone.
  • Quantitative synthetic-data quality auditing β€” synthetic image diversity was measured against real images using frozen ResNet-50 embeddings before trusting the generated data at scale, catching a ~30% mode-collapse signal that a purely visual inspection would likely have missed.
  • Bug-driven, not vibes-driven, iteration β€” every regression (M2's collapse, M3's over-correction) was root-caused with evidence before the next architecture was chosen, culminating in a dedicated audit section (19.0) and corrected, reusable utilities (safe class weighting + Macro-F1 checkpoint selection) used for every model built afterward.
  • Grad-CAM clinical explainability β€” verified that models attend to clinically plausible structures (optic disc cupping for Glaucoma, foveal drusen for AMD, hemorrhages/microaneurysms for Diabetic Retinopathy) rather than spurious background features.
  • Deliberate dual-model deployment β€” instead of picking one model and quietly absorbing its blind spot, both champions are shipped with an explicit, in-UI trade-off explanation.

πŸ“ Repository Structure

RetinaFlow/
β”œβ”€β”€ app.py                       # Gradio web app β€” dual-model inference + MCP server
β”œβ”€β”€ requirements.txt             # Runtime dependencies for app.py
β”œβ”€β”€ README.md                    # This file
β”œβ”€β”€ EyeDisease.ipynb             # Full research notebook (122 cells, training β†’ export)
β”œβ”€β”€ models/
β”‚   β”œβ”€β”€ resnet50_m5a.onnx        # M5a β€” ResNet-50, 224Γ—224 input, General-Purpose
β”‚   └── efficientnet_b5_m6.onnx  # M6 β€” EfficientNet-B5, 300Γ—300 input, High-Sensitivity
└── assets/
    └── samples/                 # Curated example fundus images (one per class)

πŸ–₯️ The App

app.py is a Gradio application with:

  • Dual-model inference via ONNX Runtime (CPUExecutionProvider) β€” no GPU required.
  • Per-model resolution dispatch β€” 224Γ—224 for ResNet-50, 300Γ—300 for EfficientNet-B5, both with ImageNet normalization.
  • Result caching β€” SHA-256 hash of the uploaded image, so repeated queries skip re-inference.
  • MCP server support (mcp_server=True) with a single scoped public endpoint (classify), so the classifier can also be called as an MCP tool from any compatible client.
  • "Quantum Black" custom theme and an explicit, always-visible trade-off banner explaining the two models before any prediction is shown.

πŸš€ Installation & Usage

# 1. Clone the repository
git clone https://github.com/markegyptian55-cloud/RetinaFlow.git
cd RetinaFlow

# 2. Install dependencies
pip install -r requirements.txt

# 3. Run the app
python app.py

The app will start a local Gradio interface (and, per Colab/HF Space environment, may also expose a temporary public share link). Upload a fundus image, choose a model, and click Classify.

Reproducing the training pipeline

The full training journey β€” from the scratch CNN through OT-CFM augmentation to the final ONNX export β€” lives in EyeDisease.ipynb. It was developed on Google Colab (Tesla T4 GPU) and expects the raw dataset structure described in Section 3.0 of the notebook.


⚠️ Limitations & Honest Caveats

This README follows the same principle as the notebook itself: no cherry-picking.

  • Hypertension numbers are statistically fragile. A 13-image test set means every recall figure for that class should be read as directional, not precise.
  • Neither champion model is "solved." M5a still misses the majority of Hypertension cases; M6 trades away real accuracy on common classes to catch more of them.
  • The generative augmentation path has a known, unresolved limitation (synthetic mode collapse, ~30% diversity loss vs. real images) that was diagnosed but not fully fixed within project scope.
  • This is not a validated clinical tool. No external clinical validation, regulatory review, or deployment safety testing has been performed.

🩺 Disclaimer

This project is provided strictly for research and educational purposes. It is not a certified medical device and must not be used for actual clinical diagnosis, screening, or treatment decisions. Always consult a qualified ophthalmologist or medical professional for any real diagnostic concern.


πŸ™ Acknowledgments

Built on top of the following public clinical fundus image registries: ODIR-5K, APTOS-2019, ACRIMA, and ORIGA. Full credit to their original creators and maintainers for making this research possible.


Made with πŸ”¬ and a refusal to hide bad results.