| # ποΈ RetinaFlow | |
| ### Dual-Model Retinal Disease Classifier β ResNet-50 & EfficientNet-B5, trained on a severely imbalanced 11.8K-image clinical dataset, augmented with OT-CFM (Flow Matching) synthetic generation. | |
|  | |
|  | |
|  | |
|  | |
|  | |
| > β οΈ **This is a research/educational project, not a certified medical device.** It is not intended for clinical use, diagnosis, or treatment decisions. See [Disclaimer](#-disclaimer). | |
| --- | |
| ## π Table of Contents | |
| - [Overview](#-overview) | |
| - [The Core Challenge: Extreme Class Imbalance](#-the-core-challenge-extreme-class-imbalance) | |
| - [Dataset](#-dataset) | |
| - [The Research Journey](#-the-research-journey) | |
| - [Final Benchmark Results](#-final-benchmark-results) | |
| - [Key Technical Contributions](#-key-technical-contributions) | |
| - [Repository Structure](#-repository-structure) | |
| - [The App](#-the-app) | |
| - [Installation & Usage](#-installation--usage) | |
| - [Limitations & Honest Caveats](#-limitations--honest-caveats) | |
| - [Disclaimer](#-disclaimer) | |
| - [Acknowledgments](#-acknowledgments) | |
| --- | |
| ## π¬ Overview | |
| **RetinaFlow** is an end-to-end deep learning pipeline that classifies retinal fundus photographs into **8 diagnostic categories**: | |
| `AMD` Β· `Cataract` Β· `Diabetic Retinopathy` Β· `Glaucoma` Β· `Hypertension` Β· `Myopia` Β· `Normal` Β· `Others` | |
| Rather than presenting a single "best" model and hiding its weaknesses, this project documents a **complete, honest experimentation log** β every architecture tried, every bug found and fixed, every hypothesis tested and killed β and ships **two champion models side by side**, letting the end user choose the trade-off that matters for their use case: | |
| | | Optimizes for | Best for | | |
| |---|---|---| | |
| | π **M5a β ResNet-50** | Overall diagnostic accuracy | General-purpose screening | | |
| | π― **M6 β EfficientNet-B5** | Minority-class sensitivity | Not missing rare, high-risk cases | | |
| --- | |
| ## βοΈ The Core Challenge: Extreme Class Imbalance | |
| The real obstacle in this project was never "build a classifier" β it was **severe class skew**. A model that blindly predicts `Normal` or `Diabetic Retinopathy` for everything already scores ~74% accuracy while being clinically useless. | |
| | Class | Train Pool | Test Set | Imbalance Ratio (vs. Normal) | | |
| |---|---:|---:|---:| | |
| | Normal | 4,698 | 705 | 1.0Γ | | |
| | Diabetic Retinopathy | 4,113 | 617 | 1.1Γ | | |
| | Others | 1,102 | 165 | 4.3Γ | | |
| | Glaucoma | 930 | 140 | 5.1Γ | | |
| | Cataract | 340 | 51 | 13.8Γ | | |
| | Myopia | 294 | 44 | 16.0Γ | | |
| | AMD | 274 | 41 | 17.1Γ | | |
| | **Hypertension** | **88** | **13** | **53.4Γ** | | |
| Because Hypertension had only 88 real training images (and just 13 in the test set), **Hypertension recall became this project's critical benchmark metric** β and its statistical volatility (each misclassified image swings recall by ~7.7pp) is called out explicitly throughout the notebook rather than glossed over. | |
| --- | |
| ## π Dataset | |
| **11,839 real fundus photographs**, unified from 4 public clinical registries: | |
| | Source Registry | Images | Share | | |
| |---|---:|---:| | |
| | ODIR-5K | 7,000 | 59.1% | | |
| | APTOS-2019 | 3,484 | 29.4% | | |
| | ACRIMA | 705 | 6.0% | | |
| | ORIGA | 650 | 5.5% | | |
| All models are evaluated on the **exact same** strictly isolated, held-out, **100% real** test set of **1,776 images** β no model was ever tested on synthetic data, and every row in the results table below is directly comparable. | |
| --- | |
| ## π§ The Research Journey | |
| The notebook (`EyeDisease.ipynb`, 122 cells) documents six model generations, each a response to a specific, diagnosed failure in the one before it: | |
| ```mermaid | |
| flowchart TD | |
| M1["M1 β Scratch CNN\nPerformance floor"] --> M2["M2 β ResNet-50 Transfer\nSilent loss-weighting bug"] | |
| M2 --> M3["M3 β Sampler + Focal Loss\nOver-corrected, majority classes collapsed"] | |
| M3 --> AUDIT1["π§Ύ Section 19.0 Audit\nRoot-causes every prior bug"] | |
| AUDIT1 --> M4["M4 β OT-CFM Flow Matching\n+1,600 synthetic minority images"] | |
| M4 --> M5a["M5a β ResNet-50 Post-CFM\nπ Champion #1"] | |
| M4 --> M5b["M5b β Swin-T\nHigher accuracy, worse Macro-F1"] | |
| M5a --> DIAG["π¬ Generative Recovery Investigation\nMode collapse confirmed, recovery attempted & abandoned"] | |
| DIAG --> M6["M6 β EfficientNet-B5\nπ― Champion #2"] | |
| ``` | |
| **Highlights along the way:** | |
| - **M1 (Scratch CNN):** 92.3% Hypertension recall looked amazing β until you notice overall accuracy was 23%. A near-random model over-predicts rare classes by noise. Lesson: never read one metric in isolation. | |
| - **M2 (ResNet-50):** Accuracy jumped to 69%, but Hypertension recall *collapsed* to 7.7%. Root cause, found later in the Section 19.0 audit: the "weighted" loss silently ran as plain Cross-Entropy due to a variable-scoping bug (`class_weights` out of scope at runtime). | |
| - **M3 (Sampler + Focal Loss):** Stacking *two* independent imbalance-correction mechanisms at once over-corrected so hard that Normal-class recall dropped to 6.8%. Textbook double-correction failure. | |
| - **Section 19.0 Audit:** A full stop-and-diagnose pass before building anything else β it surfaced the M2 bug, the flawed val-loss checkpoint selection used in M1βM3, the M3 double-correction, and the lack of any quantitative synthetic-data quality check. | |
| - **M4 (OT-CFM Flow Matching):** A class-conditional Optimal Transport Conditional Flow Matching model generated 1,600 synthetic images for the 4 weakest classes (+600 Hypertension, +350 AMD, +350 Myopia, +300 Cataract). | |
| - **Generative Recovery Investigation (19.1β19.5):** A feature-space diversity audit using frozen ResNet-50 embeddings found ~30% mode collapse in the synthetic images. A targeted fine-tuning recovery attempt was tried, measured, and found inconclusive (one class even regressed) β so the generative-model recovery path was **deliberately discontinued** rather than chased indefinitely. This is documented as a clean, evidence-based stopping point, not a failure to hide. | |
| - **M5b (Swin-T) vs. M5a (ResNet-50):** The newer transformer architecture did *not* win β ResNet-50 generalized better on Macro-F1 and minority recall, a reminder that architecture novelty isn't automatically better without enough data to justify the extra capacity. | |
| - **M6 (EfficientNet-B5):** Built after correcting the checkpoint-selection and class-weighting bugs, explicitly optimized as the "catch rare cases" counterpart to M5a. | |
| --- | |
| ## π Final Benchmark Results | |
| All numbers below are from the same 1,776-image, 100%-real, held-out test set. | |
| | Model | Accuracy | Macro-F1 | Weighted-F1 | Hypertension Recall | Verdict | | |
| |---|---:|---:|---:|---:|---| | |
| | M1 β Scratch CNN | 23.37% | 0.228 | 0.184 | 92.3% | Near-random; high recall is a noise artifact | | |
| | M2 β ResNet-50 (standard) | 69.14% | 0.534 | 0.669 | 7.7% | Strong accuracy; silent bug collapsed minority recall | | |
| | M3 β ResNet-50 (Sampler + Focal) | 25.73% | 0.298 | 0.257 | 69.2% | Over-corrected; majority classes destroyed | | |
| | **M5a β ResNet-50 (Post-Flow-Matching)** | **71.68%** | **0.600** | **0.710** | 15.4% | π **Best overall β shipped as "General-Purpose"** | | |
| | M5b β Swin-T | 72.24% | 0.573 | 0.711 | 7.7% | Higher raw accuracy, worse Macro-F1 & minority recall | | |
| | **M6 β EfficientNet-B5** | 62.61% | 0.570 | 0.653 | **38.5%** | π― **Best minority sensitivity β shipped as "High-Sensitivity"** | | |
| > Note: Hypertension recall figures are computed on only **13 test images** and carry high variance β a single misclassification shifts the number by ~7.7 percentage points. Treat these as directional, not precise. | |
| --- | |
| ## π οΈ Key Technical Contributions | |
| - **OT-CFM Flow Matching for medical data augmentation** β a class-conditional Optimal Transport Conditional Flow Matching generative model (velocity-field estimator, trained to convergence at loss 0.0235) used to synthesize minority-class fundus images, rather than relying on GANs or classic geometric augmentation alone. | |
| - **Quantitative synthetic-data quality auditing** β synthetic image diversity was measured against real images using frozen ResNet-50 embeddings *before* trusting the generated data at scale, catching a ~30% mode-collapse signal that a purely visual inspection would likely have missed. | |
| - **Bug-driven, not vibes-driven, iteration** β every regression (M2's collapse, M3's over-correction) was root-caused with evidence before the next architecture was chosen, culminating in a dedicated audit section (19.0) and corrected, reusable utilities (safe class weighting + Macro-F1 checkpoint selection) used for every model built afterward. | |
| - **Grad-CAM clinical explainability** β verified that models attend to clinically plausible structures (optic disc cupping for Glaucoma, foveal drusen for AMD, hemorrhages/microaneurysms for Diabetic Retinopathy) rather than spurious background features. | |
| - **Deliberate dual-model deployment** β instead of picking one model and quietly absorbing its blind spot, both champions are shipped with an explicit, in-UI trade-off explanation. | |
| --- | |
| ## π Repository Structure | |
| ``` | |
| RetinaFlow/ | |
| βββ app.py # Gradio web app β dual-model inference + MCP server | |
| βββ requirements.txt # Runtime dependencies for app.py | |
| βββ README.md # This file | |
| βββ EyeDisease.ipynb # Full research notebook (122 cells, training β export) | |
| βββ models/ | |
| β βββ resnet50_m5a.onnx # M5a β ResNet-50, 224Γ224 input, General-Purpose | |
| β βββ efficientnet_b5_m6.onnx # M6 β EfficientNet-B5, 300Γ300 input, High-Sensitivity | |
| βββ assets/ | |
| βββ samples/ # Curated example fundus images (one per class) | |
| ``` | |
| --- | |
| ## π₯οΈ The App | |
| `app.py` is a **Gradio** application with: | |
| - **Dual-model inference** via **ONNX Runtime** (`CPUExecutionProvider`) β no GPU required. | |
| - **Per-model resolution dispatch** β 224Γ224 for ResNet-50, 300Γ300 for EfficientNet-B5, both with ImageNet normalization. | |
| - **Result caching** β SHA-256 hash of the uploaded image, so repeated queries skip re-inference. | |
| - **MCP server support** (`mcp_server=True`) with a single scoped public endpoint (`classify`), so the classifier can also be called as an [MCP](https://modelcontextprotocol.io/) tool from any compatible client. | |
| - **"Quantum Black" custom theme** and an explicit, always-visible trade-off banner explaining the two models before any prediction is shown. | |
| --- | |
| ## π Installation & Usage | |
| ```bash | |
| # 1. Clone the repository | |
| git clone https://github.com/markegyptian55-cloud/RetinaFlow.git | |
| cd RetinaFlow | |
| # 2. Install dependencies | |
| pip install -r requirements.txt | |
| # 3. Run the app | |
| python app.py | |
| ``` | |
| The app will start a local Gradio interface (and, per Colab/HF Space environment, may also expose a temporary public share link). Upload a fundus image, choose a model, and click **Classify**. | |
| ### Reproducing the training pipeline | |
| The full training journey β from the scratch CNN through OT-CFM augmentation to the final ONNX export β lives in `EyeDisease.ipynb`. It was developed on Google Colab (Tesla T4 GPU) and expects the raw dataset structure described in Section 3.0 of the notebook. | |
| --- | |
| ## β οΈ Limitations & Honest Caveats | |
| This README follows the same principle as the notebook itself: no cherry-picking. | |
| - **Hypertension numbers are statistically fragile.** A 13-image test set means every recall figure for that class should be read as directional, not precise. | |
| - **Neither champion model is "solved."** M5a still misses the majority of Hypertension cases; M6 trades away real accuracy on common classes to catch more of them. | |
| - **The generative augmentation path has a known, unresolved limitation** (synthetic mode collapse, ~30% diversity loss vs. real images) that was diagnosed but not fully fixed within project scope. | |
| - **This is not a validated clinical tool.** No external clinical validation, regulatory review, or deployment safety testing has been performed. | |
| --- | |
| ## π©Ί Disclaimer | |
| This project is provided strictly for **research and educational purposes**. It is **not** a certified medical device and **must not** be used for actual clinical diagnosis, screening, or treatment decisions. Always consult a qualified ophthalmologist or medical professional for any real diagnostic concern. | |
| --- | |
| ## π Acknowledgments | |
| Built on top of the following public clinical fundus image registries: **ODIR-5K**, **APTOS-2019**, **ACRIMA**, and **ORIGA**. Full credit to their original creators and maintainers for making this research possible. | |
| --- | |
| <p align="center">Made with π¬ and a refusal to hide bad results.</p> | |