Download README.md from origin-data-lab/stereo-calibration-validation: direct link, hf CLI and curl.
- Browser
- Download file 6.06 kB
-
https://huggingface.co/datasets/origin-data-lab/stereo-calibration-validation/resolve/main/README.md
- Command line
-
hf download hf://datasets/origin-data-lab/stereo-calibration-validation/README.md
-
curl -L -o README.md https://huggingface.co/datasets/origin-data-lab/stereo-calibration-validation/resolve/main/README.md
license: cc-by-nc-4.0
language:
- en
pretty_name: 'Checking a Stereo Calibration on Ordinary Footage (Field Note #04)'
tags:
- robotics
- physical-ai
- egocentric
- stereo-vision
- camera-calibration
- fisheye
- epipolar-geometry
- kalibr
- opencv
- evaluation
task_categories:
- other
size_categories:
- n<1K
configs:
- config_name: default
data_files:
- split: train
path: data/evaluation_summary.csv
Checking a Stereo Calibration on Ordinary Footage
Origin Data Lab · Technical Field Note #04 · 23 October 2026
Short answer. You can check whether a stereo calibration fits a device and capture mode using ordinary footage, without a target. On a 120 s, 1600×1200 head-mounted stereo recording, a Kalibr calibration from the same capture mode gave a median angular epipolar error of 0.41 px on 19,386 unfiltered matches; a calibration of the same camera family from a different (16:9) mode gave 1.83 px. Two common checks can mislead on wide-angle lenses (see below).
Code and issues: GitHub — origin-data-lab/stereo-calibration-validation
Full article: Technical Field Note #04 — Checking a Stereo Calibration on Ordinary Footage
Key results
| Result | Value |
|---|---|
| Median angular epipolar error, mode-matched calibration, no adjustment | 0.41 px (19,386 matches, 29 frame pairs) |
| Same matches, calibration from a different capture mode | 1.83 px |
| Stereo-rotation correction requested by the data | < 0.02° per axis |
| Deliberate 0.1° pitch error | median rises to 0.76 px |
| Rectified vertical residual, 0–20° vs 75–90° field angle | 0.50 px → 4.05 px (angular metric stays 0.46 px) |
cv2.fisheye.undistortPoints (OpenCV 5.0, defaults) |
exact to ~74°; 4.5° wrong at 80°, 8.0° at 85° for this lens |
All values are from the evaluated recording and configuration; they are not universal guarantees.
Two traps on wide-angle stereo
1. Rectified vertical residuals inflate toward the image edge. Projecting wide-angle rays onto a flat rectified image stretches the periphery (roughly 1/cos² of the angle), so a correct calibration looks wrong at the edges. Use an angular metric, or restrict rectified checks to the central field of view.
2. OpenCV's default fisheye un-projection clamps the distorted angle at π/2. With a positive k₁, θd reaches π/2 before the true ray angle reaches 90°, and every point beyond returns at the wrong angle. Run tools/fisheye_roundtrip_check.py with your own coefficients to see where this happens for your lens.
Tools
pip install opencv-python numpy scipy pyyaml
# 1. Validate a Kalibr pinhole-equidistant stereo calibration on ordinary stereo footage
python tools/validate_stereo_calib.py --left left.mp4 --right right.mp4 \
--camchain camchain.yaml --scale 2 --out result.json
# --scale = video resolution / calibration resolution
# 2. Find where OpenCV's fisheye un-projection breaks for your coefficients
python tools/fisheye_roundtrip_check.py --camchain camchain.yaml --cam cam0 --scale 2
python tools/fisheye_roundtrip_check.py --k 0.12 0 0 0 --f 480 --cx 800 --cy 600
Repository contents
| Path | Contents |
|---|---|
tools/validate_stereo_calib.py |
Target-free stereo calibration check (angular epipolar error, field-angle breakdown, held-out rotation fit) |
tools/fisheye_roundtrip_check.py |
OpenCV fisheye round-trip test |
results/ |
Measured results behind the article (JSON) |
data/evaluation_summary.csv |
Key numbers as a table (shown in the Dataset Viewer) |
figures/ |
Figures used in the article |
The device calibration parameters and the source recording are not published in this repository.
What this check does not verify
- Baseline length / metric scale — absent from the epipolar constraint.
- Metric depth accuracy — requires targets at measured distances.
- Camera–IMU calibration — time shift and extrinsics need a separate test.
Cite
@misc{origindatalab2026fieldnote04,
author = {{Origin Data Lab}},
title = {Checking a Stereo Calibration on Ordinary Footage},
howpublished = {Technical Field Note \#04},
year = {2026},
url = {https://origindatalab.io/technical-field-notes/stereo-calibration-check.html}
}
Or:
Origin Data Lab (2026). Checking a Stereo Calibration on Ordinary Footage. Technical Field Note #04.
https://origindatalab.io/technical-field-notes/stereo-calibration-check.html
License
- Code in
tools/: MIT - Text, results and figures: CC BY-NC 4.0 — free to share and adapt for non-commercial use with attribution to Origin Data Lab.
Related
- All Technical Field Notes
- 한국어 — 스테레오 캘리브레이션 검증 (Field Note #04)
- #03 Stereo + IMU Egocentric Capture · dataset card
Origin Data Lab — real-world data production for Physical AI and robotics · origindatalab.io · contact@origindatalab.io