|
Download README.md from origin-data-lab/stereo-calibration-validation: direct link, hf CLI and curl.
- Browser
- Download file 6.06 kB
-
https://huggingface.co/datasets/origin-data-lab/stereo-calibration-validation/resolve/main/README.md
- Command line
-
hf download hf://datasets/origin-data-lab/stereo-calibration-validation/README.md
-
curl -L -o README.md https://huggingface.co/datasets/origin-data-lab/stereo-calibration-validation/resolve/main/README.md
6.06 kB
| license: cc-by-nc-4.0 | |
| language: | |
| - en | |
| pretty_name: "Checking a Stereo Calibration on Ordinary Footage (Field Note #04)" | |
| tags: | |
| - robotics | |
| - physical-ai | |
| - egocentric | |
| - stereo-vision | |
| - camera-calibration | |
| - fisheye | |
| - epipolar-geometry | |
| - kalibr | |
| - opencv | |
| - evaluation | |
| task_categories: | |
| - other | |
| size_categories: | |
| - n<1K | |
| configs: | |
| - config_name: default | |
| data_files: | |
| - split: train | |
| path: data/evaluation_summary.csv | |
| # Checking a Stereo Calibration on Ordinary Footage | |
| **Origin Data Lab · Technical Field Note #04 · 23 October 2026** | |
| [](https://origindatalab.io/technical-field-notes/stereo-calibration-check.html) | |
|  | |
|  | |
| > **Short answer.** You can check whether a stereo calibration fits a device and capture mode using ordinary footage, without a target. On a 120 s, 1600×1200 head-mounted stereo recording, a Kalibr calibration from the same capture mode gave a **median angular epipolar error of 0.41 px** on 19,386 unfiltered matches; a calibration of the same camera family from a different (16:9) mode gave **1.83 px**. Two common checks can mislead on wide-angle lenses (see below). | |
| **Code and issues:** [GitHub — origin-data-lab/stereo-calibration-validation](https://github.com/origin-data-lab/stereo-calibration-validation) | |
| **Full article:** [Technical Field Note #04 — Checking a Stereo Calibration on Ordinary Footage](https://origindatalab.io/technical-field-notes/stereo-calibration-check.html) | |
| --- | |
| ## Key results | |
| | Result | Value | | |
| |---|---:| | |
| | Median angular epipolar error, mode-matched calibration, no adjustment | **0.41 px** (19,386 matches, 29 frame pairs) | | |
| | Same matches, calibration from a different capture mode | **1.83 px** | | |
| | Stereo-rotation correction requested by the data | **< 0.02°** per axis | | |
| | Deliberate 0.1° pitch error | median rises to **0.76 px** | | |
| | Rectified vertical residual, 0–20° vs 75–90° field angle | **0.50 px → 4.05 px** (angular metric stays **0.46 px**) | | |
| | `cv2.fisheye.undistortPoints` (OpenCV 5.0, defaults) | exact to ~**74°**; **4.5°** wrong at 80°, **8.0°** at 85° for this lens | | |
| All values are from the evaluated recording and configuration; they are not universal guarantees. | |
| ## Two traps on wide-angle stereo | |
| **1. Rectified vertical residuals inflate toward the image edge.** Projecting wide-angle rays onto a flat rectified image stretches the periphery (roughly 1/cos² of the angle), so a correct calibration looks wrong at the edges. Use an angular metric, or restrict rectified checks to the central field of view. | |
| **2. OpenCV's default fisheye un-projection clamps the distorted angle at π/2.** With a positive k₁, θd reaches π/2 before the true ray angle reaches 90°, and every point beyond returns at the wrong angle. Run `tools/fisheye_roundtrip_check.py` with your own coefficients to see where this happens for your lens. | |
| ## Tools | |
| ```bash | |
| pip install opencv-python numpy scipy pyyaml | |
| # 1. Validate a Kalibr pinhole-equidistant stereo calibration on ordinary stereo footage | |
| python tools/validate_stereo_calib.py --left left.mp4 --right right.mp4 \ | |
| --camchain camchain.yaml --scale 2 --out result.json | |
| # --scale = video resolution / calibration resolution | |
| # 2. Find where OpenCV's fisheye un-projection breaks for your coefficients | |
| python tools/fisheye_roundtrip_check.py --camchain camchain.yaml --cam cam0 --scale 2 | |
| python tools/fisheye_roundtrip_check.py --k 0.12 0 0 0 --f 480 --cx 800 --cy 600 | |
| ``` | |
| ## Repository contents | |
| | Path | Contents | | |
| |---|---| | |
| | `tools/validate_stereo_calib.py` | Target-free stereo calibration check (angular epipolar error, field-angle breakdown, held-out rotation fit) | | |
| | `tools/fisheye_roundtrip_check.py` | OpenCV fisheye round-trip test | | |
| | `results/` | Measured results behind the article (JSON) | | |
| | `data/evaluation_summary.csv` | Key numbers as a table (shown in the Dataset Viewer) | | |
| | `figures/` | Figures used in the article | | |
| The device calibration parameters and the source recording are not published in this repository. | |
| ## What this check does not verify | |
| - **Baseline length / metric scale** — absent from the epipolar constraint. | |
| - **Metric depth accuracy** — requires targets at measured distances. | |
| - **Camera–IMU calibration** — time shift and extrinsics need a separate test. | |
| ## Cite | |
| ```bibtex | |
| @misc{origindatalab2026fieldnote04, | |
| author = {{Origin Data Lab}}, | |
| title = {Checking a Stereo Calibration on Ordinary Footage}, | |
| howpublished = {Technical Field Note \#04}, | |
| year = {2026}, | |
| url = {https://origindatalab.io/technical-field-notes/stereo-calibration-check.html} | |
| } | |
| ``` | |
| Or: | |
| ``` | |
| Origin Data Lab (2026). Checking a Stereo Calibration on Ordinary Footage. Technical Field Note #04. | |
| https://origindatalab.io/technical-field-notes/stereo-calibration-check.html | |
| ``` | |
| ## License | |
| - Code in `tools/`: MIT | |
| - Text, results and figures: [CC BY-NC 4.0](https://creativecommons.org/licenses/by-nc/4.0/) — free to share and adapt for non-commercial use with attribution to Origin Data Lab. | |
| ## Related | |
| - [All Technical Field Notes](https://origindatalab.io/technical-field-notes/) | |
| - [한국어 — 스테레오 캘리브레이션 검증 (Field Note #04)](https://origindatalab.io/ko/technical-field-notes/stereo-calibration-check.html) | |
| - [#03 Stereo + IMU Egocentric Capture](https://origindatalab.io/technical-field-notes/stereo-imu-egocentric-sample.html) · [dataset card](https://huggingface.co/datasets/origindatalab/stereo-imu-egocentric-evaluation) | |
| --- | |
| **Origin Data Lab** — real-world data production for Physical AI and robotics · [origindatalab.io](https://origindatalab.io) · [contact@origindatalab.io](mailto:contact@origindatalab.io) | |
| Need per-device, per-capture-mode stereo calibration validated on your own footage? [Contact us](https://origindatalab.io/contact.html). | |