| From: Test engineering lead, Larkfield Electronics (Unit 7, board test bay) | |
| To: Automation team, Corrie Bench Systems | |
| Subject: FT-2 fixture: loading controller for the SO-101 | |
| Hi, | |
| The FT-2 bench fixture is wired and the SO-101 is bolted down next to it, but we still load every board by hand. | |
| We want the arm to do the whole cycle so the bay can run unattended for the night shift. Please write the | |
| controller. | |
| One cycle: | |
| - A board under test sits on the two locating pins of the fixture nest. The nest gets moved and turned a little | |
| every time someone services the bay, so take its pose from the overhead camera each cycle. | |
| - Two cables come out of the cable duct at the back: a DC barrel plug (5.5 mm) for power and a 2-pin keyed | |
| header for the test signals. The barrel plug lies loose on the bench in front of the duct. The header plug sits | |
| in its parking socket on the right-hand side of the bench. | |
| - The arm plugs the barrel plug into the board's DC jack (it goes in sideways, along the jack axis) and the | |
| header plug into the shroud on the board, key rib to the slot. The header latches with a click when it is | |
| fully home. The DC jack has no latch; its spring contact holds it. | |
| - Then it presses the green TEST button on the nest. The fixture runs the test (one to three seconds) and lights | |
| the pass or fail lamp. Both lamps and the power and probe signals are on the fixture I/O. | |
| - After a pass, the arm unplugs both connectors, sets both plugs down on the bench clear of the nest, lets go, | |
| and goes home. The header latch has to be pressed to release the header; pulling a latched header breaks the | |
| latch. | |
| What must not happen: | |
| - Boards lifted off their pins. If a board comes up off the pins it has to be re-seated by hand and the test is | |
| void. Unplugging is where this usually happens. | |
| - Bent jacks and cracked shrouds. Any sideways load on a connector while it is engaged bends the contacts. | |
| Pushing too hard on the way in does the same. Our limits are in the acceptance sheet. | |
| - Crushed plug housings. They are thin nylon. | |
| - Slow cycles. The bay is sized for 100 s a board. | |
| Things change from board lot to board lot and from cable to cable: the fit of the jack and the shroud (between | |
| 0.3 and 1 mm of clearance), which revision of the board it is (the header sits in a different place on revisions | |
| A, B and C, and engineering samples can have it anywhere along that edge), and how stiff the cables are. | |
| The arm's mount has never been levelled properly. There are three touch-off probes on the bench for that: spring | |
| plungers with a switch, read on the I/O. Use them. | |
| If the gripper or the camera fails during a cycle, the arm must stop and report which one failed. It must not | |
| carry on blind. | |
| The acceptance sheet is `ACCEPTANCE_TESTS.md` and the fixture and cell data are in `CELL_SHEET.md`. Please don't | |
| change the cell model or the acceptance files. | |
| Thanks, | |